Ask our experts a question about this part and we'll get back to you as soon as possible!
2 questions answered by our experts.
< Prev
1
Next >
Sort by:
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Sorry, we couldn't find any existing answers that matched.Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Joe
January 17, 2024
I bought a new temperature probe for the top oven, part #5304525427 and still didn’t fix error code F30. Check ohms on new probe at 500ohm where existing probe in bottom oven reads 1000ohm. Bottom oven works fine. Took probe out of bottom oven and installed in top oven and error code F30 cleared and top oven works fine. Tried new probe in bottom oven and got error code F31. Why do these new probes #5304525427 not work? Found original probe part #318562500 is no longer available. What’s a person to do?
For model number FGEF306TPFA
Hello Joe, thank you for your inquiry. Based on the description that you have provided, we would recommend replacing the relay control board, part number PS10064722, to fix the issue. It receives signals from the main oven control board. The relay control board operates relays to regulate the oven elements. We hope this helps!