Water Inlet Valve 205613

Official part for Maytag, Amana, Kenmore, Speed Queen

★★★★★
★★★★★
(16)

Really Easy 

15 - 30 mins 

Part Location Diagram of 205613 Whirlpool Water Inlet Valve
See part 1 in the diagram
Replacing your Maytag Washer Water Inlet Valve
( Grid squares measure 1x1 inch )
Proudly Canadian
$156.71
In Stock
Order within the next 1 hr and 34 mins and your part ships today!

Part Fit Check - Make Sure it's a Match.

About This Part

What it does. Why it matters. Everything you need to know for an easy fix.

Water Inlet Valve Specifications

This part has two ports for water to enter. It is blue and is intended for use with many washing machines and comes with a multi-mount bracket and an outlet adaptor.
Part #205613
Manufactured by Whirlpool for Maytag, Amana, Kenmore, Speed Queen

You May Also Need

Genuine OEM: Original Parts. Lasting Repairs.

Because quality isn't optional.

OEM stands for Original Equipment Manufacturer. This means that the company who made your appliance is also supplying the replacement part.

How Buying OEM Parts Can Save You Time and Money
Features OEM Generic
Genuine brand name
Guaranteed to fit
Superior Quality
Long term value

Part Videos

Watch our pros, then fix it yourself.

Replacing your Maytag Washer Water Inlet Valve

Replacing your Maytag Washer Water Inlet Valve

About this fix

Common problems and models this part fixes.

Really Easy 

15 - 30 mins 

What this part fixes:
  • No hot or cold water
  • Leaking
  • Water Filling Issues
Works with the following products:
  • Washer
  • Washer Dryer Combo
  • Freezer
Part# 205613 replaces these:
AP4023852, 3440, 205613, 2-3177, 2-3847, 2-4028, 2-5613, 2-5614, 203177, 203847, 204028, 205613, 205613VP, 205614, 21001605, 22002882, 25832, 25832R, 8400-525

Customer Reviews

Real ratings from other people who bought this part.

Average Rating:

★★★★★
★★★★★
16 Reviews
4.9

Out of 5

  • 5 Stars
    15
  • 4 Stars
    1
  • 3 Stars
    0
  • 2 Stars
    0
  • 1 Star
    0
Sort by:
  • 1
  • 2
Sorry, we couldn't find any existing reviews that matched. Try using some different or simpler keywords.
  • 1
  • 2

Repair Tips

See how others fixed this model. Time, tools, difficulty, and steps that lead to victory!

Really Easy 

15 - 30 mins 

Average repair rating from 87 real customers like you

Sort by:
  • 1
  • 2
  • 3
Sorry, we couldn't find any existing installation instruction that matched.
Cold water valve only opened to a trickle
600 of 619 people found this instruction helpful.
  • Brian from El Cajon, CA
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Wrench (Adjustable)
I started by unplugging the appliance and then shut off the hot and cold water faucets then I disconnected and drained the hoses. Next, I removed the two screws that held the valve assembly in place. I then pulled the assembly out about 3 inches and disconnected the two wire plugs. The last step was to loosen the hose clamp on the outlet hose and pull off the outlet hose. I reversed the steps to install the new assembly and the total repair took about 10 minutes.
Was this helpful?
Thank you for voting!
washer filled with water even when OFF.
55 of 60 people found this instruction helpful.
  • wayne from lees summit, MO
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers, Wrench (Adjustable)
Followed your directions and it went very easy.
Only took maybe 30 mins.
I was impressed with your trouble shooting and inst!!!!

Thanks

wayne
Was this helpful?
Thank you for voting!
Cold water solinoid not opening properly
44 of 50 people found this instruction helpful.
  • Erich from EastHampton, CT
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Pliers, Screw drivers
I moved wash machine away from wall and unplugged from wall outlet. Shut off water, then removed hot and cold water lines from water inlet valve,removed screw from mounting plate and removed valve from wash machine. Checked to see if replacement valve was compatible (exact fit).
Unscrewed the two screws holding valve to mounting plate,unscrewed hose clamp and removed water line at top of valve (outlet). Removed the four wires from solinoids.Replaced the four wires onto the new valve as they were on the old valve,reattached water line onto the top of valve and tightened.Reattached valve to mount plate with the two screws and mounted back onto machine. Hooked up hot and cold water lines back onto valve and snugged with pliers. Turned on water checked for leaks (no leaks), and did a load of laundry. Super simple,well worth doing yourself.
Was this helpful?
Thank you for voting!
Cold water would not flow into the washer
30 of 35 people found this instruction helpful.
  • john from friendswood, TX
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
After verifying that the supply wasn't the problem, I ordered the replacement inlet valve module.

1) shut off water to machine
2) removed the hose connections from the valve
3) unplugged the washer
4) removed the plate holding the module - 1 screw
5) removed the hose clamp from the valve module to the washer inlet
6) removed the two screws holding the valve module to the plate
7) removed the 2 wire connections to each of the two solenoids.
8) Reversed all of the steps above for the new valve module.
9) checked for leaks
Was this helpful?
Thank you for voting!
cold water barely flows, hot is ok
26 of 27 people found this instruction helpful.
  • James from Bedford, TX
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Pliers
These Maytag people know how to build stuff. I was impressed with this valve. Built really smart. After a gazillion years (about 16 or so) the valve started making a funny groaning noise and the cold water flow was very slow. Took about 15-20 minutes to fill the tub.

the inlet valve is located on the back of the washer where the hoses are connected. In fact the hose connectors are part of the valve.

To replace this valve, start by unplugging and turning off the water spigots, unscrew the two hoses from the valve. (you need a towel here, but that'll be obvious soon enough.)

Unscrew the single screw at the top of the valve bracket (the bottom of the bracket is held in place without screws.) Remove the screw holding on the sheet metal and pull the bracket out as far as you can without stretching things. Write down what colors of wire are connected, then pull off the electrical connectors.

The valve outlet is a skinny (compared to the inlet hoses) rubber hose that has a clamp to hold it in place. The clamp needs to be loosened with a 3/16" nutdriver a plier would probably work, but may be hard to get in there. Now slide the clamp further up on the hose, dislodge the rubber hose off of the old valve. Now it's free.

Reverse the steps. Believe it or not, that is all. It works great and this washer probably has another 10 year left in it.
Was this helpful?
Thank you for voting!
No hot water
16 of 17 people found this instruction helpful.
  • Joel from New Canaan, CT
  • Really Easy
  • 15 - 30 mins
  • Pliers, Socket set
Went on the PartSelect website, input the problem, and got the Water Inlet Valve as the diagnosis. When the part arrived, I viewed the short video on replacing the Water Inlet Valve and just followed the instructions. It could not have been easier. After turning off both the hot and cold water and pulling the plug from the wall socket, I removed the screw holding the bracket and valve to the machine; removed the 2 screws holding the valve to the bracket; removed the wire harness ends from each solenoid on the valve; replaced the valve with the new one and reattached the wire harness, followed by reattaching the bracket to the valve, and assembling to the machine.
Was this helpful?
Thank you for voting!
Water inlet valve failed
14 of 16 people found this instruction helpful.
  • Lawrence from Eau Claire, WI
  • Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
Disconnect the water lines. Remove two screws that hold the water valve to the back of the machine. Pull the water valve out and remove the panel that holds it on to the machine. Remove the water line from the valve to the wash tub. Remove the four wires from the valve remembering where each one goes on the new unit. Attach the valve to tub hose to the new unit. Attach the four wires in the proper order to the new unit . Screw the metal holding panel on to the valve. Push the unit in place and reattach with the two screws. Attach the water lines and use the machine. Remember to unplug the machine prior to changing the valve
Was this helpful?
Thank you for voting!
The fill cycles would start then stop suddenly
14 of 24 people found this instruction helpful.
  • Peter from Aurora, IL
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Pliers, Screw drivers
This was an easy repair.
1st I removed both water hoses
2nd I removed 1 hex head screw that released a backing plate & removed the plate holding the water inlet valve.
3rd I pulled the 4 electrical connections & loosened a clamp to remove a small water hose.
4th I removed 2 hex head screws that held the water valve to the backing plate.
-----------that was a whole 5 - 10 minutes!------------
Next I reversed the process
4th I attached the inlet valve with the 2 hex head screws
5th re-attached the 4 electrical connections(had slip on spades) pushed on the hose & tighterned the clamp.
6th replaced the backing plate with the inlet valve attached & tightened the single hex head screw.
7th re-attached the hot & cold lines................................DONE
15 minutes tops
Was this helpful?
Thank you for voting!
Water would not shut off.
12 of 13 people found this instruction helpful.
  • Allen from Bedford, PA
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Pliers, Screw drivers
Replaced old valve with new one.
Was this helpful?
Thank you for voting!
replace failed valve
8 of 8 people found this instruction helpful.
  • Robert from Geneva, IL
  • Easy
  • 15 - 30 mins
  • Screw drivers
Of couse, turn off water to machine. Remove hoses. Then had to open unit - easiest by popping spring in with flat blade in seam under lid. Screws holding valve are on back of unit at hose inlet, so simply unscrew to remove failed valve. Clamp holding hose onto valve is crimped with pliers to remove. I suggest spending the 50 cents a hardware store for new clamp, as my reattachment of existing clamp onto new value leaked. There are four electrical connectors, so remember order in which you removed them and return to same on new unit.
Reassemble in reverse (hoses, water on) and your all set.
Pretty easy: I figure it would be about $200 for service guy and part. My cost: $30 and 30 minutes
Was this helpful?
Thank you for voting!
  • 1
  • 2
  • 3

DIY Questions and Expert Answers

18 questions answered by our Repair Experts.

Ask our experts a question about this part and we'll get back to you as soon as possible!

Sort by:
  • 1
  • 2
Sorry, we couldn't find any existing answers that matched.Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Lucy - For model number A712
April 17, 2018
My washer fills slowly with cold water when it is not on. If I put my finger under the rim inside the tub, it is wet. I've got the problem under control by turning off the cold water at source when not in use, but I'd like to fix it, if possible!
Chris Boyle Profile
Hi Lucy, Thank you for the question. This would be an issue with the Water Inlet Valve, PartSelect Number: PS1583805. The valve can become stuck open and allow water to leak info the tub when not in use. Hope this helps!
24 people found this instruction helpful.
Was this helpful?
Thank you for voting!
Tom - For model number LSE7800ACL
October 7, 2017
Hi lid switch was bad because of solenoid. Part is unavailable so bypassed lid switch. The machine will not fill with water on start up but will do rinse cycle. The water inlet switch is new. Did i louse up something bypassing the lid switch. Thankstom
Chris Boyle Profile
Hi Tom, Thank you for your inquiry. If your washing machine is not filling with water then you may have check the continuity of the lid switch to see if it is working correctly. A lid switch that is not working correctly can cause this issue. I hope this helps. Thank you and have a great day!
9 people found this instruction helpful.
Was this helpful?
Thank you for voting!
Todd - For model number A482
March 30, 2018
Hello, the warm and hot water fill for wash cycles but no cold water for the wash and rinse cycles. I removed some sediment in the screens but still no cold water. Cold water flows through the fill hoses...thanks!
Chris Boyle Profile
Hi Todd, Thank you for your question. It sounds like the cold water solenoid might be broken on your valve. You can test the part to see if that is the case, but it sounds like you will need to replace your valve. I hope that helps. Good luck with your repair.
6 people found this instruction helpful.
Was this helpful?
Thank you for voting!
Stu - For model number LA112
April 25, 2018
Tub overflows when not in use. I use only cold water with hot turned off at source, would that be the problem? Thank you
Chris Boyle Profile
Hi Stu, Thank you for the question. This sounds like an issue with the Water Inlet Valve, PartSelect Number: PS1583805. The valve may have become stuck open and is allowing the water to flow through when not in use. Hope this helps!
5 people found this instruction helpful.
Was this helpful?
Thank you for voting!
Rich - For model number A9400
April 4, 2019
I have no selection of water mixture. I only have warm/cold. When i switch it to any of the others like hot/warm, cold/cold etc the water just trickles in. What could be the problem?
Chris Boyle Profile
Hello Rich, Thank you for the question. This sounds like an issue with the temperature Switch, PartSelect Number PS2017425. I looked up the part and it is listed as No Longer Available/Discontinued. There is no part substitutions listed. My suggestion here would be to call the manufacturer and see if they can provide you with a substitution for these part numbers. Hope this helps!
2 people found this instruction helpful.
Was this helpful?
Thank you for voting!
John - For model number LAT7800ABW
September 5, 2023
since replacing the cold water hose the water temperatures are no longer what the 4 switches say they should . ie; cold/cold now gives out hot only and other 3 screwed up to . Help
Chris Boyle Profile
Hello John, thank you for getting in touch. To help you replace the water inlet valve correctly, we have attached a relevant video to help you with the process. It will resolve the hot and cold water issue. Glad to be of assistance!
2 people found this instruction helpful.
Was this helpful?
Thank you for voting!
Tom - For model number A512
May 8, 2023
Washing machine leaks water onto floor, but only when warm water is used. Does not leak water on cold/cold cycle.
Chris Boyle Profile
Hi Tom, thank you for reaching out. We would recommend checking for any kinks/damages to the hoses and tightening any loose connections. If that does not help, then the issue is most likely related to the water inlet valve, part number PS1583805. We hope this sorts out your problem!
1 person found this instruction helpful.
Was this helpful?
Thank you for voting!
Milon
April 22, 2019
I have a top loading Amana washer that the hot water constantly run is it the inlet valve stuck open
Chris Boyle Profile
Hello Milon, thank you for contacting us, In order for us to locate the correct parts and repair information we will require the model number of the unit. Once you have located the model number please feel free to resubmit the question and we will be happy to help you. Look forward to hearing from you!
1 person found this instruction helpful.
Was this helpful?
Thank you for voting!
Savannah
November 28, 2017
Only the cold water intake vale is stripped, do i need to replace both hot and cold intake vale
Chris Boyle Profile
Hi Savannah, Thank you for your question. If this is the valve that you would need to replace, you would have to replace the whole thing. Unfortunately it does not come in parts. I hope that helps. Good luck with your repair.
Was this helpful?
Thank you for voting!
David - For model number LAT9593AAW
May 24, 2019
While the tub is filling water runs out of the crack between the cabinet and the top in the left rear corner right above the water inlet valve.
Chris Boyle Profile
Hi David, thank you for your question. It sounds like you might want to inspect your valve to see if it is broken or if the hoses that attach to it are broken and need to be replaced. I hope that helps. Good luck with your repair.
Was this helpful?
Thank you for voting!
  • 1
  • 2

This Part Also Fits These Models

Don't see your model? Use our Fit Checker to confirm!

Check Part Fit
Part #205613
Brand
Model Number
Description
Kenmore
1985816100
Freezer
Kenmore
1985816150
Freezer
Kenmore
1985816151
Freezer
Kenmore
1985816152
Freezer
Kenmore
1985816153
Freezer
Kenmore
1985816200
Freezer
Kenmore
1985818100
Freezer
Kenmore
1985818101
Freezer
Kenmore
1985818150
Freezer
Kenmore
1985818151
Freezer
Kenmore
1985818200
Freezer
Kenmore
1985818201
Freezer
Kenmore
6637300
Air Purifier - 2-Speed Portable Electronic Air Purifier
Maytag
A104
Washer - Top Loading
Maytag
A105
Washer - Top Loading
Maytag
A106
Washer - Top Loading
Maytag
A106S
Washer - Residential
Maytag
A107
Washer - Top Loading
Maytag
A107S
Washer - Residential
Maytag
A108
Washer - Top Loading
Maytag
A108S
Washer - Residential
Maytag
A110
Washer - Top Loading
Maytag
A112
Washer - Top Loading
Maytag
A15CA
Washer
Maytag
A15CM
Washer
Maytag
A15CT
Washer
Maytag
A16CA
Washer
Maytag
A16CM
Washer
Maytag
A16CT
Washer
Maytag
A17CA
Washer