Bill
November 5, 2018
Which part and it’s number is known as the “user interface” ?Thanks
For model number MEDB400VQ
Hi Bill, thank you for your question. This part would be the user interface for your appliance. I hope that helps. Good luck with your repair.
1 person found this helpful.
Was this helpful?
Thank you for voting!
Fred
February 21, 2019
My dryer is not drying. The Flame ignites stays on for about 8 10 seconds than turns off for 45 or so secs and turns on again and continues to cycle on an off. I checked the vent not clogged, i replaced just about every sensor in the dryer and problem persists. Could it be the circuit board? If yes is there any way to test since part is very expensive.Thanks.
For model number MGDB400VQ0
Hello Fred, Thank you for the question. You may have a weak igniter, PartSelect Number: PS334180 or a flame sensor, PartSelect Number: PS11741429. I suggest testing them with a multi meter and check for continuity. Hope this helps, good luck with this repair!