Was Not Making Ice Or Getting Water
3 of 6 people found this instruction helpful.
  • TERESA from COALMONT, TN
  • Really Easy
  • Less than 15 mins
  • Wrench (Adjustable)
Three easy steps, take off old part then all you do is tighten nut on one end of part and then just push other end of pipe down in slot. Did half to remove nut off the top end of tube very simple to do
Was this helpful?
Thank you for voting!
Ice maker stopped making ice
2 of 3 people found this instruction helpful.
  • Robert from Wyckoff, NJ
  • Easy
  • 15 - 30 mins
  • Screw drivers
I had made a dry run at the repair after watching the instructional film provided by part select and it seemed easy enough.
The only problem was that i needed to use the electrical cord extender (provided) to adapt to my plug type. That presented a problm because it needed to be tucked up out of the way to allow the ice bin to clear . Just needed to be creative in how you wrapped the cord behind the ice maker unit before snugging the attachment screws.
Cranking out ice like crazy.
Was this helpful?
Thank you for voting!
Refrigerator not defrosting, ice tray clogging up in ice tray, refrigerator making loud humming noise, and compressed running all the time.
2 of 3 people found this instruction helpful.
  • Mark from ROSEMOUNT, MN
  • A Bit Difficult
  • 30 - 60 mins
  • Screw drivers
First, turn off power - since I did not want to pull the refrigerator out on my wood floor I tripped the circuit breaker to that circuit and opened door to make sure interior light was off (ensuring power was off). This unit has a bottom freezer, I took out all shelves, ice maker and all parts in the way of accessing back of interior of f reezer section. Removed back plastic section by removing one screw in middle top of back panel and prying it out. This was a bit difficult as it was in there a bit tight but once the plastic warmed up it pulled out ok. This revealed the compressor section and temp sensor that was attached to the copper coils with of all things - a zip tie! In pictures of this that I looked at on various web sites the sensor was on a metal bracket attached to the coil so it made me wonder if tf the factory took a shortcut? I cut the old sensor wire, stripped the two wires 1/2", and connected them to the new sensor wire with butt connectors, I put some silicone into the ends of the butt connectors to prevent moisture from entering into connectors and wrapped the connection in black electrical tape. I then "attached" the sensor to the coil using a zip tie, put the plastic back piece back on, inserted everything I took out and put power back to refrigerator. It's been 3 days and temp of refrigerator is stable, ice maker not clogging up, and compressor not running all the time! So far so good.
Was this helpful?
Thank you for voting!
Ice Maker Did Not Work
2 of 3 people found this instruction helpful.
  • Donald from Jacksonville, FL
  • Easy
  • 30 - 60 mins
  • Pliers, Screw drivers
Tried replacing water valve since no water in ice cube tray. Exact part not available due to age of refrigerator, but I got the equivalent replacement part for $18. Mounting holes different, but I made it work. Also one connect on new one slip connect whereas both compression fittings on old valve. I put it back together and icemaker no w works great.
Was this helpful?
Thank you for voting!
Defroster fan burned up
3 of 6 people found this instruction helpful.
  • Peter M. from Lincoln Park, NJ
  • Easy
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers, Socket set
First I removed the ice tray rack lifting it out of the way to reach the back cover of the fan. Then, the whole back inside panel had to be removed. Two screws removed the fan and bracket from the freezer unit. The missing bumper lid just snapped into place. Replaced everything in reverse order. Pretty easy job.
Was this helpful?
Thank you for voting!
icemaker quit working when we moved
4 of 10 people found this instruction helpful.
  • Regina from Taylorsville, KY
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
My husband took out the old icemaker in about 5 minutes. The new icemaker was a perfect fit even though the refrigerator was >10yrs old. The only difficult part was the plug extension that was needed so that it would fit into an older appliance. The part was included, it just made the cord about 3 inches longer than it needed to. After wo rking with it for about 20 minutes we were able to fit it on the back side of the icemaker. Now it works great!!
Was this helpful?
Thank you for voting!
Water valve failed. Constant drip in ice maker.
1 person found this instruction helpful.
  • Steven from RUSHVILLE, IL
  • Easy
  • 30 - 60 mins
  • Screw drivers, Socket set, Wrench set
Removed old valve easily. New WR57XI0033 valve is designed to mount on lower left, but on mine it has to mount on lower right. Had to drill two 1/32 holes in lower rail to mount the new valve.
Was this helpful?
Thank you for voting!
Loud Sound In Freezer
1 person found this instruction helpful.
  • Carolyn from Santa Ana, CA
  • Really Easy
  • 30 - 60 mins
  • Pliers, Screw drivers, Socket set
I followed the video for my model refrigerator on parts select. My hint: when returning the back panel of the freezer, it's slightly adjustable left and right to avoid grazing the fan.
Was this helpful?
Thank you for voting!
Fan making noise.
1 person found this instruction helpful.
  • Matthew from Escondido, CA
  • Really Easy
  • 30 - 60 mins
  • Screw drivers
Remove ice maker and all of it's accessories in order to remove the panel covering the fan. Don't drop the screws!
Unscrew the lower fan bracket. You will see the lower red rubber grommet. Hold fan motor with one hand and push the fan off the shaft and into the compartment above. Then remove the round retainer thing below it by holdi ng it and pulling down on the motor assembly. Install new grommet on upper part. and put it all together.
REMEMBER where the fan is on the shaft. It has about one inch of shaft placement. I put mine so that most of it was above the hole that the fan goes into and about 20 percent showing below the sheet metal.
Also check to see if your fan is damaged. Mine was not.
This refrigerator has been awesome! I have had many issues but have been able to fix all of them for the last 15 years!
Was this helpful?
Thank you for voting!
Fan was not centered in the middle of the back panel opening.
1 person found this instruction helpful.
  • James from GREENSBORO, NC
  • Easy
  • 30 - 60 mins
  • Screw drivers, Socket set
Bent the motor bracket down, then using a rat tail file, elongated the holes in the back panel of the refrigerator to secure the fan in the "centered" position. This was a problem that was with the refrig. since it was made. The parts involved were perfect. NO problem at all installing them.
Was this helpful?
Thank you for voting!
Would only drain intermittenly
1 person found this instruction helpful.
  • C. from Lexington, KY
  • Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
Thought it might be check flapper valve on drain pump, so I replaced fairly easily, per instructions. When doing, I noticed the attached relay wires were not secure. When it was on the drain cycle one of the relay wires vibrated badly and loosened the connection enough to only work occasionaly. Would like to put new relay on the pump bu t they do not sell separately from the pump. (one assembly). I resecured connection and will wait till relay gives out and buy new assembly, but for now it's working perfectly!
Was this helpful?
Thank you for voting!
Bottom of refrigerator wouldn't coool
2 of 4 people found this instruction helpful.
  • Charles from El Dorado, AR
  • Easy
  • 15 - 30 mins
  • Nutdriver
I removed the top vent and unplugged the ice machine ,took the back cover off the freezer.Removed the old fan which was pretty easy(unplugged it after I took the housing out for easy access) I plugged the new fan in and put everything back in the order I took off, and yada yada yada we have cooling.
Was this helpful?
Thank you for voting!
Bad tasting ice cubes
2 of 4 people found this instruction helpful.
  • susan from hartford, WI
  • Really Easy
  • 15 - 30 mins
Took the old filter out and put the new one in.
Easy Breezy!!
Was this helpful?
Thank you for voting!
Refrigerator not getting cold
1 person found this instruction helpful.
  • Dan from COLUMBIA, SC
  • Really Easy
  • 15 - 30 mins
  • Pliers, Socket set
Replaced Temperature Sensor and now it is getting cold.
Was this helpful?
Thank you for voting!
Ice maker stopped working
1 person found this instruction helpful.
  • Cary from ORLANDO, FL
  • Really Easy
  • 15 - 30 mins
  • Pliers
Remove the one screw holding the unit in place, unplug it, slide in the replacement, plug and screw it in.
Was this helpful?
Thank you for voting!