ZIS360NRK General Electric Refrigerator - Instructions

All Instructions for the ZIS360NRK
61 - 75 of 341

Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!

Search filter:
Clear Filter
Your search term must have 3 or more characters.
Compressor would not kick on and condenser fan ran constantly
6 of 6 people found this instruction helpful.
  • Charles from ORO VALLEY, AZ
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers, Socket set
Remove back panel on bottom of fridge to access compressor area. Remove screws from water solenoid and water valve and push to the side so the side of the compressor can be accessed. Then locate the inverter box. You will find a Phillips head screw on the bottom of the inverter. This is the only screw that hold the inverter in place. Remo ve the screw and tilt the inverter box forward away from the compressor, then lift the box out of the the holder. You may have to wiggle it a bit to get it out. Remove the plug that attaches to the compressor and then with the power on check your voltage coming to the compressor. It should read 120 volt. If it doesn’t your inverter is bad. Remove the other plug on the inverter box and pull the box out.
Reinstall the unit in reverse order. Use the appropriate jumper to plug into the wire connection going to box and then plug it into the connection off the fridge.
Once everything is reinstalled and before you put the back panel on plug your refrigerator back in and you should be able to hear the compressor working or feel the top of it to make sure. If it’s working you are good and can reinstall the back panel.
It will take 4-5 hours to come back to temp if it’s been off for any length of time.
Was this helpful?
Thank you for voting!
burnt out bulb
13 of 27 people found this instruction helpful.
  • Neal from Gardena, CA
  • Really Easy
  • Less than 15 mins
  • Screw drivers
removed light cover and replaced defective bulb
Was this helpful?
Thank you for voting!
no water to icemaker
6 of 7 people found this instruction helpful.
  • Ron from Clinton, MO
  • Really Easy
  • Less than 15 mins
  • Screw drivers, Wrench (Adjustable)
turned off water supply, took screws out of bracket, then unhooked water lines. Installed water lines onto new valve, plugged it in then screwed bracket back onto fridge, turned on water and was back operating
Was this helpful?
Thank you for voting!
Noise coming from rear of fridge
7 of 10 people found this instruction helpful.
  • Edward from SILVER SPRING, MD
  • Very Easy
  • 15 - 30 mins
  • Nutdriver
Remove rear plate. Remove fan bracket. Replace fan gaskets, blade and motor. Replace bracket. Replace rear plate. Very simple. Fixed the problem.
Was this helpful?
Thank you for voting!
Red Spring Broke - Refrig Sect. Door Closure
8 of 13 people found this instruction helpful.
  • Jack B from Walnut Creek, CA
  • A Bit Difficult
  • 15 - 30 mins
  • Pliers, Screw drivers
I found that I did not have the strength to stretch the new spring enough to install it initially. Using a 1/8 or 5/32 inch allen wrench I removed the pivot for the arm that the spring applies tension to. This allowed the spring to be easily attached to the hole in the arm and to the post in the bottom of the refridgerator. I then used a small pliers to grab the arm in front of its pivot hole and pull it against the spring into position to replace the pivot. Replacing the filter was surprisingly easy. I turned the water supply valve off under the sink and easily unscrewed the old filter (about a quarter turn). I filled the new filter with water and srewed in in. No wrenches required. I turned the water back on under the sink and everything works great!
Was this helpful?
Thank you for voting!
Noisey evap motor
7 of 11 people found this instruction helpful.
  • Peter from Kalispell, MT
  • Easy
  • 30 - 60 mins
  • Nutdriver
I tried to quite the noisey evap motor with special liquid motor grease from Radio Shack. It did not work, so I ordered the evap motor. My freezer motor was wired slightly different than the motor I received. The replacement motor had a male plug attached to the four wires, the original motor was different, so I cut the wires and splic ed them into the original freezer wires (colors were the same). Remounted motor. Works great, and no more groaning motor
Peter
Was this helpful?
Thank you for voting!
Unit had stopped making ice
5 of 5 people found this instruction helpful.
  • Ron from ORANGE, CA
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
Ordered the icemaker replacement. unplugged the unit, followed the simple instructions and got it done in less than 30 minutes. It did take a LONG time to start making ice. But it's working now.
Was this helpful?
Thank you for voting!
light not working
7 of 11 people found this instruction helpful.
  • robert from FRANKLIN SQ, NY
  • Very Easy
  • Less than 15 mins
  • Pliers, Screw drivers
I used pliers to pull lightly on the head of the switch, while I inserted a small flat head screw driver into the base of switch and gently worked around the edges to free it from the panel.
Was this helpful?
Thank you for voting!
ice maker barely working
6 of 8 people found this instruction helpful.
  • William from Provencal, LA
  • Really Easy
  • Less than 15 mins
  • Screw drivers, Wrench (Adjustable)
Repair was very simple. Removed refridgerator bottom back panel, about 6 or 7 screws. disconnected bad valve, installed new valve , connected water supply line and then reinstalled panel. Took about 15 minutes from start to finish.
Was this helpful?
Thank you for voting!
Noisy refrigerator
6 of 8 people found this instruction helpful.
  • Eric from NEW YORK, NY
  • A Bit Difficult
  • 1- 2 hours
  • Nutdriver, Screw drivers
I visually inspected the compressor and narrowed down the source of the noise to the freezer area. Then I removed the doors and the screws securing the divider panel. Next I removed the bottom panel of the freezer, the styrofoam insullation panel and the evaporator motor. The motor is mounted between two grommets. I replaced the gromme t facing the fan blades. The aluminum reflector below the styrofoam insulation panel had also come loose. I reattached it and reassembled the refrigerator in reverse order. The noise is gone!
Was this helpful?
Thank you for voting!
broken auger in the bucket assembly.
6 of 9 people found this instruction helpful.
  • Chip from Mandeville, LA
  • Easy
  • Less than 15 mins
  • Nutdriver
I ordered the wrong part, the ice maker assembly, because your diagram was not marked properly. I returned the part and you credited my account. Thanks. Ordered the new bucket. It worked fine. Now I have ice and crushed Ice whenever I want. Thanks.

p.s. I didnt use any tools, but to satisfy you I select nut driver.
Was this helpful?
Thank you for voting!
Ice Maker would not fill.
5 of 6 people found this instruction helpful.
  • Charles from Keller, TX
  • Easy
  • 15 - 30 mins
  • Screw drivers
Was concerned that new icemaker was quite a bit different than the one we were replacing. Called GE to confirm it was correct.

Went ahead and installed the unit, using the supplied electric cable adapter.

A little difficult to deal with the extra cable, but everything worked OK and it's making ice normally.
Was this helpful?
Thank you for voting!
The Icemaker failed to make ice
8 of 16 people found this instruction helpful.
  • Dean from Folsom, CA
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
I pulled the refrigerator away from the wall and turned off the water to the refrigerator and unplugged it from the wall. After removing the icebucket from the freezer I located the mounting screws, loosened them, unplugged the electrical connection below the icemaker and carefully removed it from the freezer. I unpacked the replacement i cemaker, matched it against the original and attached the electrical connection adapter. Using the slots provided on the new icemaker I placed it over the mounting screws after aligning the water inlet pipe properly. I tightened the mounting screws while maintaining the icemaker in a level position. I plugged in the electrical connector. Then I replaced the icebucket, plugged in the refigerator back into the 110VAC outlet, turned on the water and repositioned the refrigerator in it's normal position.
Was this helpful?
Thank you for voting!
Not Cooling
4 of 4 people found this instruction helpful.
  • ROBERT from OCALA, FL
  • Really Easy
  • 30 - 60 mins
  • Screw drivers, Wrench set
-Pulled refrigerator out to access back.
-Removed compressed paperboard cover.
-Found compressor running by the feel.
-Removed metal cover to control board.
-Found ~5V coming from control board to inverter (variable frequency drive) board assembly attached to compressor.
-Found ~120 going to inverter board.
- Removed inverter board assembly from compressor.
-Found equal resistance (~7 ohms for mine) at all three contacts of inverter (DC) compressor.
-Ordered inverter assembly, plus one extra and control board for possible future use so not to loose all my food again; I might order a compressor so I have it before price goes up.
-Installed inverter when arrived.
-Used air compressor to blow out accumulated dust on condenser coil.
-Closed up and cleaned up (C^2).
-Fridge cooled and back to proper temperature the next day.
Was this helpful?
Thank you for voting!
freezer drop temp to 12 degrees.recommended temp zero.
4 of 4 people found this instruction helpful.
  • clyde from RIALTO, CA
  • Difficult
  • 30 - 60 mins
  • Nutdriver, Screw drivers
Replace the motor fan on condenser and clean the condenser
Was this helpful?
Thank you for voting!
All Instructions for the ZIS360NRK
61 - 75 of 341