Burner would not go on on my Stack Set Dryer
Took out two front Panel screws and removed the panel. Removed Gas solenoid coil holding bracket by removing two phillips head screws. Disconnected the coil leads. and removed the coils. Connected the new coils to the leads and set in place. Replaced the holding bracket and the two screws. Replaced the front cover and the two front cover screws. Piece of Cake!
Parts Used:
M Series New Style Coil Kit M Series New Style Coil Kit
  • Robert from North East, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
16 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Quick and simple - quickest $100 I've ever saved!
Removed the two screws under the lint trap
Opened the top (had to use flathead screwdriver to release latches)
Disconnected door switch harness from front panel
Removed 2 screws holding front panel on dryer
Lifted out dryer drum (previous belt had broken)
Vacuumed inside of dryer (found $3 in quarters!)
Put new belt around drum
Put drum back in dryer, using empty laundry soap bottle to support its weight
Looped belt around pulley and motor; secured pulley to dryer bottom
Made sure rear gasket thingy was aligned properly and drum turned freely
Put front panel back on
Re-attached door switch
Closed top and put screws back in under lint trap
Fired it up - WOOHOO!
Parts Used:
Maintenance Kit
  • Kelly from Waukegan, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers, Wrench (Adjustable)
13 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No Heat
First time ever repaired anything let alone a dryer, I watch the video and followed instructions, was pretty simple, Works like a charm
Parts Used:
Thermal Cut-Off Fuse Kit Dryer Thermal Fuse
  • stacy m from akron, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
18 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
dryer not heating up
Unscrewed 4 screws,pulled off front of machine.Unscrewed 2 screws holding coils on,unplugged coils,installed new coils,plugged in coils,reinstalled 2 screws for hold down brace.Reinstalled front cover,plugged dryer into outlet(remember to unplugged dryer before working on it).started up,instant heat,works great.thanks Partselect for helping me out!!!
Parts Used:
M Series New Style Coil Kit M Series New Style Coil Kit
  • Richard from New Windsor, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
12 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Wore bearing, idler pulley.
Unplug dryer from receptial. Poped top off, useing thin bladed screw driver to push tintion springs, while pulling up on lid. removed two no 10 sheet metal screws, useing 1/4 nut driver, this removes loading door by pulling uo 1/4 inch. Removed twi NO 10 sheet metal screws useing 1/4 nut driver, removed front carrage system. Removed belt then tub. Removed idler arm spring useing plires, used 5/8 inch socket removed sholder bolt with arm. Reverced procedure with one execption. Used two by four to hold tub up so belt could be put on, rolled tub to alline belt. Not bad for 70 Years young. Curtiss
Parts Used:
Idler Pulley Arm with Wheel Drive Belt
  • Curtiss from Morgan City, LA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers, Socket set
15 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The Dryer would not get hot.
I removed the two screws holding the access panel, and removed the access panel. Then removed the lower air duct. I then checked the burner, The solenoid was not opeing the valve for the gas. I order the coils, in two day I had the coils and installed them. The dryer is working great.
Parts Used:
M Series New Style Coil Kit M Series New Style Coil Kit
  • Jerry from Bradenton, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
14 of 20 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The dryer was not fully drying
After replaceing several parts including the thermostats the last part I replaced the coils were the defective part. I originally metered out the themostats and they appeared to be okay but since this was my first time I thought I might have been mistaken. It turns out the last part I thought it could be was the part that was defective. I will say that it is very simple to replace any of the parts involved. The hardest part was trying to open the dryer itself. But after having to do it 3 times, I'm now a pro. I also replaced the drum belt and since I had it open I also replaced the belf idler with a newer modified idler rolller.

Putting the belt back on is easy, but it helps to view the video or a picture to understand how the belt goes around it.
Parts Used:
M Series New Style Coil Kit M Series New Style Coil Kit
  • Michael from Chicago, IL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers, Socket set
12 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Bearings wore out of drum rollers
I raised the top of the dryer, removed the front, the belt and the drum. Slipped off old rollers, installed new ones and new tensioner. Reinstalled drum and belt, bolted front back on and closed the top.
Parts Used:
Maintenance Kit
  • Judy from Kalamazoo, MI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
11 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
When using the dryer the cycle would stop and display E1 as the reason
Unscrewed the bottom panelof the dryer and located the thermistor through the schematic for my machine. Removed the old one and put the new one in the same way. No more E1 problems and all cycles now complete themselves.
Parts Used:
Thermostat, Internal-Bias
  • Joyce from Holbrook, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
12 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Noisy
Used putty knife to release catches on dryer top. Removed two screws in Lint Filter cover. Used Nut driver to remove the screws holding the front on. Removed the drum and had easy access to all the parts I was having trouble with. I believe the real problem was the Idler pulley but since I was already there I replaced the drum rollers also. While drum was out I vacuumed the inside of the cabinet. After parts were replaced i put everything back together in reverse order. Very Easy
Parts Used:
Dryer Drum Support Roller Idler Pulley Arm with Wheel
  • Greg from SAN ANTONIO, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
10 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Had to convert from natural gas to propane
Well, here's the rub...in order to find out what part I needed to order, I needed to take the dryer apart to where the gas controls are, and there on a sticker was a part number for an LP conversion kit. But, in order to get to that gas valve unit, I fumbled about figuring out how to take this brand new dryer apart, since there were absolutely no instructions whatsoever in the owners manual. And once apart, and pretty much all apart, I wondered how it would be that the Maytag repair man would be so lonely, as he'd have plenty to do.
However, the kit had great instructions as to how to take it apart and change out the orifices.
Parts Used:
Liquid Propane Conversion Kit
  • Peter from The Rock, GA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers, Socket set
12 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Close would not get dry. Dryer started normal. Timer would not time out.
Getting to any of the parts in the Maytag dryer is easy. Tip the dryer back and slide a 4 x 4 block under the front edge. You remove the whole front panel after you remove two screws at the bottom corners of the front panel. You need to tip the dryer back to get a screwdriver on the screws. Swing the front panel up to release the top of the door panel from the top. Watch the short wires to the door switch. Unhook the door switch wires and move the front panel out of the way. The timer on the top is accessed by re-moving two screws along the top edge. There are four screws. Remove them all and tip the top of the front panel forward. You then see that two screws hold the panel and the other two screws just hold the trim.

The dryer started normal. The drum motor run when the start button was operated. The fluff cycle operated normal to indicate the timer motor was OK. On the dry cycles, the igniter heated up. The gas came on. The dryer run for some period of time and then the flame went off. The thought was that the low temp cycle thermostat sensed the dryer was hot and thus switched over to time the cycle to its end. However, the low temp cycle thermostat tested good with a meter when the sensor was removed from the dryer and heated with a light bulb. Burnt contacts in the sensor were a possible problem. I also though the radiant sensor may be bad and not recycling after it got hot. After time, the igniter would cycle on but the gas flame would not come on. I thought the radiant heater might not be tripping the secondary coil on the gas valve. The gas valve coils tested good. I was checking them cold after the dryer had cooled down. I ordered a number of parts.

I got lucky and did a test on the coils while the dryer was still hot. One of the coils in the dual booster holding coil was going open when hot. When cold it had enough continuity to let the gas valve cycle on once. After the coil got warm it went open and shut the gas valve off. When the coil did cool off, it again had continuity. I was about ready to trash the dryer when I finely found the problem. I am happy I persisted and worked the problem through to a solution. I purchased several extra sensors but saved money in the long-run. I rate this problem at the high end of complexity for the do-it your self home owner to solve. The problem was an easy fix once the real problem was found. Only 4 screws and 3 push on wire connectors (two were on the front panel for the door switch).
Parts Used:
M Series New Style Coil Kit M Series New Style Coil Kit
  • Roger from Westminster, SC
  • Difficulty Level:
    Very Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Screw drivers
12 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
LP gas conversion
Followed instructions, except to advoid sharp edges, and completed the job in under an hour.
Parts Used:
Liquid Propane Conversion Kit
  • Robert from Palmdale, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Socket set
11 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Gas Dryer would heat for one heating cycle but no gas afterward. Ignitor would glow.
Checked four thermocouples all showed continuity with my multimeter so they were all good. I'd read that the coils commonly went out and that these were the symptoms. Hey, it's very simple in there. Not much else could be wrong. I had a Maytag repairman come out. At first he said the problem was a blocked vent. I knew he was wrong. Then he said one of the thermocouples went out. It was $80 for him to come out. It turned out that his second diagnosis was wrong too. To repair the dryer by Maytag would have cost me $240. I gave him $80 and bought the coils for $37. They are EXTREMELY easy to replace: two screws held a bracket that held two coils. With the bracket off, I took off the old coils and slid on the new ones.
Parts Used:
M Series New Style Coil Kit
  • Jim from Foothill Ranch, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Rollers were wore out
Just follow the instructions the one was provided with Maitanace kit we bought from you.
Parts Used:
Maintenance Kit
  • Chandra from Orange, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers, Wrench (Adjustable)
9 of 10 people found this instruction helpful.
Was this instruction helpful to you?