TDDP5013ES2P Midea Dehumidifier - Parts

1 - 12 of 45

Enter a part description. DIY Heroes keep it simple, eg. "belt" or "pump".

Search filter:
Clear Filter
Your search term must have 3 or more characters.
Pipe Temperature Sensor – Part Number: 11201007003439
No Longer Available
Pipe Temperature Sensor
Part #11201007003439
Universal Wheel – Part Number: 12620100000015
No Longer Available
Universal Wheel
Part #12620100000015
Centrifugal Fan – Part Number: 12100103000075
No Longer Available
Centrifugal Fan
Part #12100103000075
Installation Bracket Subassembly – Part Number: 12120100000594
No Longer Available
Installation Bracket Subassembly
Part #12120100000594
Dobber Case – Part Number: 12120100002228
No Longer Available
Dobber Case
Part #12120100002228
Handle Of Water Tank – Part Number: 12120100005563
No Longer Available
Handle Of Water Tank
Part #12120100005563
Butt Joint Subassembly – Part Number: 12120100005983
No Longer Available
Butt Joint Subassembly
Part #12120100005983
Water Tank Assembly – Part Number: 12120100A15797
No Longer Available
Water Tank Assembly
Part #12120100A15797
Drain Pipe – Part Number: 12600501000024
No Longer Available
Drain Pipe
Part #12600501000024
Continuous drainage depends on a clear and properly fitted pump hose. Replace the hose if it is split, blocked, leaking, or too stiff to seal well. First inspect the pump outlet and make sure the drain path is open. Confirm the correct hose using the complete dehumidifier model number. Disconnect power and remove any stored water before installation. Do not pinch or twist the new hose. After reconnecting it, run a short test and check every fitting for leaks.
Suction Pipe Assembly – Part Number: 15120100001774
No Longer Available
Suction Pipe Assembly
Part #15120100001774
Humidity Sensor Assembly – Part Number: 17120100000344
No Longer Available
Humidity Sensor Assembly
Part #17120100000344
Steady moisture control depends on a working humidity sensor. A damaged sensor may cause the dehumidifier to run too long, stop too soon, or show the wrong humidity level. First check the room temperature, air filter, airflow, and control settings. Confirm the replacement with the complete appliance model number. Disconnect power and empty the water bucket before service. Handle the sensor and wires gently. If the readings remain incorrect after replacement, the control board may need testing.
Capacitor – Part Number: 17400103000060
No Longer Available
Capacitor
Part #17400103000060
When the fan runs but the compressor does not start, the run capacitor may need testing. A failed capacitor can be swollen, leaking, or unable to hold the correct charge. Do not touch its case or terminals. It may store dangerous electricity even after the appliance is unplugged. Check the model number and all ratings before ordering a replacement. Other starting parts and the compressor should also be tested. Ask a qualified repair technician to discharge, remove, and install the capacitor safely.