Door latch broken
2 of 2 people
found this instruction helpful.
-
Kathy from SAN DIEGO, CA
- Very Easy
- 15 - 30 mins
-
Screw drivers
I read your instructions sent with the new latch. Looked at a couple videos online and it was VERY easy to change the part. Thanks so much?
Was this helpful?
Thank you for voting!
The Door Latch on the Avantium Microwave Oven
2 of 3 people
found this instruction helpful.
-
Sherman from Memphis, TN
- Easy
- Less than 15 mins
I removed the door, by taking off the grill at the top. Then, take the puddy knife and screw driver and pry the facing off of the door. Please remember to be very careful because this is a sensitive piece. This is the most difficult part. It is a piece of cake after this. This should take about 15 minutes from beginning to end.
Was this helpful?
Thank you for voting!
Door handle latch
2 of 3 people
found this instruction helpful.
-
Karen from Bend, OR
- A Bit Difficult
- Less than 15 mins
-
Screw drivers
We opened the microwave door and essentially with a straight screwdriver worked to "pop" the plastic frame off of the door. We tried to be less aggressive in our efforts and this paid off since we didn't break anything! The area we needed to work on was now exposed to put the new latch in. It took 2 hands rather than 3 to get the new latc
... Read more
h attached and then wah-lah, It was done! Microwave works perfectly now. Great alternative to buying a new microwave!
Read less
Was this helpful?
Thank you for voting!
the TCO is a temperature fuze on the side of the exhaust outlet. When the exhaust registers too high a heat temperature the fuze blows and stops the entire unit from working.
2 of 3 people
found this instruction helpful.
-
James C from ARLINGTON, TX
- Easy
- 15 - 30 mins
-
Screw drivers
I replaced the TCO (fuze) through the vent opening after removing the vent cover and several small panels with a screw driver for visible access.. Some of the screws require a small offset screwdriver because of the limited access. I did not have to drop the unit from the wall over the range and was able to access through the vent openi
... Read more
ng to replace to failed TCO with a new one. The TCO is wired in-line with the power and other fuses to the unit and when it fails the enitire unit is cold with no power to lights or function of any kind. The GE service rep. said that the unit needed a new smart board but that was not the problem and they are no longer made for the older unit. I discovered the repair by looking at YouTube for repairs for the GE Advantium 120 microwave/convection combo unit.
Read less
Was this helpful?
Thank you for voting!
Bad door switch and divide
3 of 6 people
found this instruction helpful.
-
Robert from COLORADO SPGS, CO
- Easy
- 30 - 60 mins
-
Screw drivers
Remove upper grill, then control panel, then 2 screws hold door switch mounting bracket, that will let you roll the switches out to work on them. Remove each switch by carefully pushing back retainer clips. Diode a long pair of needlenose pliers is helpful. The control board in front of capacitor comes out with a flat screwdriver and pry
... Read more
up. Removing grnd wires helps
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
broken latch
1 person
found this instruction helpful.
-
Wilson from Pembroke Pines, FL
- Easy
- 30 - 60 mins
-
Screw drivers
We used the scresdriver(flat) to remove the frame inside the door, the remove several screws retaining the inner part of the door thenremoved the broken piece. We replaced the latch with the spring With a little patience, everything went fine. I broke one of the small tab, no big deal.
thanks, you saved me a lot of money/.
thanks, you saved me a lot of money/.
Was this helpful?
Thank you for voting!
Turntable Stopped Working/Display Timer Would Countdown But Not Heat
1 person
found this instruction helpful.
-
Steve from Wesley Chapel, FL
- Really Easy
- 30 - 60 mins
-
Screw drivers
With this model, you must remove the outer covering. Don't try to access the display unit from the front like I've seen in some other GE microwave videos. After removing the outer covering, the switches are easy to replace. They are very visible and easy to get to without taking any other parts off. You will see the door switches just
... Read more
behind the display board. Remove the switch and then remove the connecting wires to ensure you don't inadvertently brake a wire. You will need a tamper resistant star bit to remove 3 or 4 screws from the back panel. All other screws are philips head. I went ahead and replaced both switches (yes...there are two of them) and works like a charm. I saved an $800 microwave for less than $60 and know what to do if it happens again. Appears to be a common problem on this model. Thanks for others making a post...It saved me time and money reading others remarks. Good luck!
Read less
Was this helpful?
Thank you for voting!
no power in microwave in turn table wouldn't turn light would work act like door was open
5 of 13 people
found this instruction helpful.
-
johnny from port orange, FL
- Easy
- 1- 2 hours
-
Screw drivers
remov cover to check voltage and found problem at the interlock switch ohm the switch and found it was open replace both switches it work fine now
Was this helpful?
Thank you for voting!
The unit would run when the door was open!
1 person
found this instruction helpful.
-
Mike from BLUFFTON, SC
- A Bit Difficult
- 1- 2 hours
-
Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
First I had to accept the fact that the unit was designed to keep non-professional people from doing any repairs. The switch was installed in such a manner that I had to break the mounting to remove the switch, then drill a hole in the mounting to secure the new switch in place.
Was this helpful?
Thank you for voting!
Try to heat food and fuse would blow.
8 of 22 people
found this instruction helpful.
-
bart from new sarpy, LA
- A Bit Difficult
- 1- 2 hours
-
Screw drivers
Went on Youtube and pulled up how to fix a microwave.
Was this helpful?
Thank you for voting!
bulb burned out
1 person
found this instruction helpful.
-
Rusty from PHENIX CITY, AL
- Very Difficult
- More than 2 hours
-
Screw drivers
removed micro from cabinet, took off top piece and bottom piece, took off top and side piece to get to bulb. Removed bulb, replaced. Like someone said the engineers at GE should get an award for making an easy job very difficult.
Was this helpful?
Thank you for voting!
Microwave/Convection over lamp burnt.
1 person
found this instruction helpful.
-
gleason jay from ENCINITAS, CA
- Easy
- 15 - 30 mins
-
Screw drivers
Phillips screws out of the side; torx screws out of the bottom/back and slide the cover off of the back. The light is not visible but not hard to find: on the top left side mounted on a black plastic base with 1 phillips screw & stud holds other side. You can tell what the base looks like from the new part. GE probably wants you to call t
... Read more
hem to make the $-ha. Stay clear of any capacitors (shock) or chips (short) & touch the chassis to ground or if a tech, wear a ground strap.
Read less
Was this helpful?
Thank you for voting!
M/W would not start. control panel OK
1 person
found this instruction helpful.
-
Jeffrey from FULSHEAR, TX
- A Bit Difficult
- 30 - 60 mins
-
Pliers, Screw drivers
unplugged power
removed main black cover.
located part WB24X10047 and replaced
removed main black cover.
located part WB24X10047 and replaced
Was this helpful?
Thank you for voting!
Timer, light and control pad worked. Turn table and heat did not work. Oven would not start up.
1 person
found this instruction helpful.
-
Pearlie from Beulaville, NC
- A Bit Difficult
- 30 - 60 mins
-
Screw drivers
I first read where someone had the same problem. Their solution was a burned-out fuse. I ordered a new fuse...installed it and that did not solve my problem. I revisted PartSelect and read how Marla (from Arlington, TX)solved her problem. I purchased a secondary switch and when it arrived, I made a copy of Marla's instructions and followe
... Read more
d them to the letter. I installed the new secondary switch into the secondary space, put everything back together and the oven STILL DID NOT WORK. I had to take the latching panel apart again and test each switch to see if there was another bad one. I found that the third switch was burned out. So I took the new switch out of the second slot and installed it into the third slot. I tested the switches before reinstalling the latching panel. This time everything worked. So I put everything back together, reinstalled the microwave on the wall, tested it again, and everything worked perfectly.
Read less
Was this helpful?
Thank you for voting!
Microwave would not heat up
1 person
found this instruction helpful.
-
Suzanne from POWELL, OH
- Really Easy
- 15 - 30 mins
Part just snapped into place and wires were reattached.
Was this helpful?
Thank you for voting!