Refigerator Not Staying Cold
5 of 5 people
found this instruction helpful.
-
Marsha from BEVERLY, MA
- A Bit Difficult
- 1- 2 hours
-
Nutdriver, Screw drivers, Wrench set
Bought the defrost timer based on PartSelect recommendations, installed it and no change. Apparently the old one was fine but since the refrigerator was in a flood and this part got submerged in water I kept it rather than returning it. I looked at everything closely and realized all the mechanical functions were working properly. Rarely
... Read more
does a condenser coil fail so I decided to look into recharging the coolant. Bought a 1/4 inch bullet valve, a 12oz. can of R-134a and a cheap resealable can adapter with hose, gauge and R22 to R-134a adapters. After a $30. investment Bingo, after one squirt the refrigerator began to cool and after 4oz. it now works better than new. I understand that PartSelect is in the business of selling only their parts but please consider that there can be other simple problems.
Read less
Was this helpful?
Thank you for voting!
Fridge made a hellacious noise and wasn't cooling well
5 of 5 people
found this instruction helpful.
-
Bruce from MARTINEZ, CA
- Really Easy
- Less than 15 mins
-
Nutdriver
From discussions with friends, I determined the problem might be easy to fix. The fridge made a lot of noise, but the compressor DID come on, and inside the freezer was cold, but the main fridge was warming.
After unplugging the fridge, I removed the fan assembly in the freezer (there were about 4 nuts and a couple of plugs to ... Read more uncouple.
I could see right away the fan blades has broken off, but the motor looked good. The new new fan pushed easily onto the shift and fit perfectly in the housing.
I reinstalled the fan assembly, plugged in the fridge, and right away heard the new fan come on - very quietly. What was a roar became a whisper and the fridge was down to 38 degrees with a few hours.
After unplugging the fridge, I removed the fan assembly in the freezer (there were about 4 nuts and a couple of plugs to ... Read more uncouple.
I could see right away the fan blades has broken off, but the motor looked good. The new new fan pushed easily onto the shift and fit perfectly in the housing.
I reinstalled the fan assembly, plugged in the fridge, and right away heard the new fan come on - very quietly. What was a roar became a whisper and the fridge was down to 38 degrees with a few hours.
Read less
Was this helpful?
Thank you for voting!
Freezer was running too warm
6 of 8 people
found this instruction helpful.
-
Jeanne from SAN ANTONIO, TX
- Very Easy
- Less than 15 mins
-
Screw drivers
Removed the old defrost timer by removing 4 screws on the holding bracket. Disconnected the wire harness. Reconnected the wire harness to the new part. Installed the new part with 2 screws on the top of the molded bracket. I am a 67 year old woman... easy-peasy. (the defost timer is located in the bottom left rear of the freezer.
Was this helpful?
Thank you for voting!
Fridge would not cool at all, because the compressor was not running. Fan running, lights working, just no cool.
4 of 4 people
found this instruction helpful.
-
David from ABINGDON, VA
- Easy
- 15 - 30 mins
-
Screw drivers
Remove the cardboard access cover at the bottom back of the fridge. On the left side, locate the run capacitor. Remove it by prying it loose from its socket, after first removing the wire hold down clamp. One wonders why the clamp is there, which makes it difficult to get the run capacitor out. Be careful not to disrupt in any way the cop
... Read more
per refrigerant tubes. If you mess them up, you will have wasted your time and effort trying to repair the machine. I was lucky, since a failed run capacitor is the problem only about 12% of the time, based on what I’ve read. Hallelujah! It was the problem with my fridge.
Read less
Was this helpful?
Thank you for voting!
I had a broken fan blade due to ice build up from a leaking ice maker.
5 of 7 people
found this instruction helpful.
-
gary from ARANSAS PASS, TX
- Easy
- 30 - 60 mins
-
Nutdriver
1. I took out one screw on the ice maker and loosened the other two screws and unplugged and removed the ice maker.
2. Next I took out 2 screws from the bottom of the auger drive box and unplugged the wiring harness and removed the box. The wiring harness was a little tricky. The lock on the plug pushes in to unlock even though ... Read more it looks like it pulls out,.
3.next you must remove 2 screws from the left side bracket that holds the auger box and remove the bracket.
4.Now take out 8 screws that hold the back panel in place and remove the back panel.
5. now your looking at the evaporator fan blade and motor. The simple way to replace the fan blade is to unplug the motor and remove it from the freezer. It just sits in with nothing holding it. The fan requires a little pressure but should pull right off. Install new fan blade and put everything back in the same order it was removed.
2. Next I took out 2 screws from the bottom of the auger drive box and unplugged the wiring harness and removed the box. The wiring harness was a little tricky. The lock on the plug pushes in to unlock even though ... Read more it looks like it pulls out,.
3.next you must remove 2 screws from the left side bracket that holds the auger box and remove the bracket.
4.Now take out 8 screws that hold the back panel in place and remove the back panel.
5. now your looking at the evaporator fan blade and motor. The simple way to replace the fan blade is to unplug the motor and remove it from the freezer. It just sits in with nothing holding it. The fan requires a little pressure but should pull right off. Install new fan blade and put everything back in the same order it was removed.
Read less
Was this helpful?
Thank you for voting!
Pushbutton light switch failed.
4 of 5 people
found this instruction helpful.
-
Arlee from HOUSTON, TX
- Very Easy
- 15 - 30 mins
-
Screw drivers
Needed a Phillips head screwdriver to remove bottom plate (kick panel). UNPLUGGED FREEZER. Removed plate pulled switch out through the mounting hole and unhooked the two electric wires. Plac
... Read more
ed wires on new switch, pushed wires back through the hole and seated the switch. Plugged in the freezer and opened the door - magic, the light came on. Replaced the front kick panel (hardest part was to line up the plate holes with the holes in the mounting bracket).
Read less
Was this helpful?
Thank you for voting!
Defrost Timer
4 of 6 people
found this instruction helpful.
-
DAVE from LOS RANCHOS, NM
- Very Easy
- Less than 15 mins
-
Screw drivers
The old defrost timer started making a screeching noise (probably bearings going out). The replacement part was a cinch to install. When I initially spoke to a PartsSelect person, they said the part number I gave them was not consistent with my old '94 Tappan Freezer. They were able to still find the proper replacement part number. Th
... Read more
e video that was on-line helpful also.
Read less
Was this helpful?
Thank you for voting!
bad gasket seal
3 of 3 people
found this instruction helpful.
-
Jason from WHITEWATER, WI
- Very Easy
- 30 - 60 mins
-
Screw drivers
removed old one and replaced with new
Was this helpful?
Thank you for voting!
Freezer wasn't cooling - compressor not engaging
2 of 2 people
found this instruction helpful.
-
Judy from ROYSE CITY, TX
- Really Easy
- 30 - 60 mins
Ordered the Capacitor and the Thermostat Control. Parts were received in a matter of a few days, easy to install, but did not fix the problem. Had to call a repairman to fix the problem (compressor relay - this part not available to order for this model number with Parts Select). Will continue to use Parts Select in the future for other p
... Read more
arts, but not happy that the actual part I needed was not available - had to use other methods.
Read less
Was this helpful?
Thank you for voting!
I knockedoff the door light sensor when I dropped a frozen jug of ice
2 of 2 people
found this instruction helpful.
-
Rob from HILLSBORO, NH
- Very Easy
- 15 - 30 mins
-
Screw drivers
I removed the plate (recommend using a magnetic phillips head screw driver to remmove screws which are recessed). I removed the old part and pushed the new part through the hole and carefully reached in behindto attach the wires to the new part.
Was this helpful?
Thank you for voting!
Freezer not cooling due to icing up of coil.
2 of 2 people
found this instruction helpful.
-
Thomas from GRANBURY, TX
- Really Easy
- 15 - 30 mins
-
Screw drivers
The timer in this older unit is clearly exposed at the back of the freezer underneath the freezer compartment. It is attached with two Phillips head screws. After the screws are removed, the timer can be unplugged and the new one plugged in. The new timer has an extra flange to allow it to be used on more than one model of freezer. In
... Read more
order to mount the timer in this unit, you have to remove the extra flange by carefully cutting it away from the timer body, in similar fashion to what's depicted in the online video. This will allow you to mount the new timer to the mounting plate using the two screws from the old timer.
Read less
Was this helpful?
Thank you for voting!
Coils were freezing up. Defrost cycle not working
2 of 3 people
found this instruction helpful.
-
Stirling from FORT WORTH, TX
- Easy
- 15 - 30 mins
-
Screw drivers
First unplug freezer, then disconnected wires from timer.
Removed 2 screws from bracket holding time to freezer.
Attached New part with screws. .The mounting bracket is now part of New time. Reattach wires.
I let coils defrost and then plugged it.
Removed 2 screws from bracket holding time to freezer.
Attached New part with screws. .The mounting bracket is now part of New time. Reattach wires.
I let coils defrost and then plugged it.
Was this helpful?
Thank you for voting!
Evaporator fan not working
1 person
found this instruction helpful.
-
Randolph from Edwards, MS
- Really Easy
- 30 - 60 mins
-
Screw drivers, Socket set
Took off cover, unplugged wires, removed old motor, mounted new motor, remounted new motor and replaced cover.
Now need a new control board for same model.
Now need a new control board for same model.
Was this helpful?
Thank you for voting!
Evaporator Fan Motor burnt out because fan got stuck in frame wall during transportation
1 person
found this instruction helpful.
-
Dmitriyev from Ruther Glen, VA
- Really Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers
1st Turn off power. Removed freezer racks. Removed access panel to bottom back of freezer. Disconnect the wire harness to fan motor. Use 5/16 nut driver for removing fan motor from support. Removed fan blade from motor and put fan blade on the new fan motor. Bought new fan blades, but new fan blade would not work on new motor. Spring moun
... Read more
t would fit on new fan blades, so I use the old one. Installed everything in reverse. Put everything back. Place thermometer in freezer. Freezer cooled down to -10F in 10 minutes. Great save on this one because I bought this freezer off of Facebook marketplace. Saved me $250. Good thing I know about fixing refrigeration equipment. Easy day.
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
Fridge quit working.
1 person
found this instruction helpful.
-
Bill from Bay City, MI
- Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers, Wrench set
A little research told me the hum plus no cooling was either the compressor or the relay. I ordered the new relay and put it in but it didn't fix the problem. I ended up having to buy a new fridge, but it was worth the $30 gamble to see if I could fix it on the cheap and it saved me the money a service call would've cost. Pretty easy i
... Read more
nstallation, just in a tight space on my model.
Read less
Was this helpful?
Thank you for voting!