frezer not staying cold enough to freze newly added product
took the shelves out, unscrewed the rear panel,unpluged the thermistat and uncliped it from the line.Replaced with new thermistat in the reverse order. Before turning the unit back on,allowed the coils to defrost.All of the process was shown in your vidio that I was able to view while ordering the part. Thank you
Parts Used:
Defrost Thermostat
  • Robert H. from Grand Blanc, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
13 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer had stopped cooling for almost 30hours.
Turned thermostat down and freezer began to run. Once it was at desired temp it shut down and did not start again. Turning the thermostat down again caused the freezer to start again. At this point, decided the thermostat was defective.Unplugged the freezer and removed the shelving. Removed the knob from the thermostat. Removed the nine screws that held the back panel in place and pulled the panel forward. Removed the assembly that held the sensing tube in place and removed the sensing tube from it. Depressed the thermostat latch which holds it in the back panel and separated it from the panel. Removed the electrical connections and removed the thermostat assembly from the freezer. Reinstalled the new thermostat in the reverse order.
Parts Used:
Temperature Control Thermostat
  • Rex from Ritzville, WA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
9 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer would not run; no electrical power to the compressor
Looking on-line at your diagnostic for this problem, I saw the most common part to cause this problem was the start capacitor, so I purchased one & installed it with no positive outcome. I then purchased the next recommended part which was a defrost timer & installed it with no run again. Frustrated, I looked at another diagnostic web site that claimed 90% of the time the problem is caused by the cold control thermostat. I tested mine and it tested bad, so I bought a control elsewhere, since your site did not list a PN for that device. I installed the new control and the freezer started up correctly. Looking at the wiring diagram for these parts, I see the start capacitor and defrost control are downstream of the cold control thermostat, and to my mind should have been the first part recommended for testing versus the parts I bought, so I am somewhat disappointed in the diagnostics on your site, where I spent about $80 for parts that were functional.
Parts Used:
DEFROST TIMER
  • Gary from SEQUIM, WA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
9 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Evap fan motor intermitant
Removed evap cover from Commercial Refrigerator. Removed mounting screws from Evap motor mount. Replaced evap fan motor. Repositioned. Reinstalled evap cover. Tested . This motor was hard to find locally. Glad I called.
Parts Used:
FAN MOTOR EVAP 115V
  • Mike from Los Banos, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
11 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker failed
Watched YouTube video. Very easy. Used my cell phone camera in ‘selfie’ mode propped up in the upper right hand corner of freezer to see the 2 hidden screws.
Parts Used:
Refrigerator Ice Maker Assembly
  • Mary from SOUTH LYON, MI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
9 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker stopped working
Took off old part and installed new part
Parts Used:
Water Inlet Valve
  • Fred from Las Vegas, NV
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
11 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
defrost thermostat was open most of the time and didn't let the defrost element heat up.
Removed evaporator cover, unplug 2 wires to thermostat, unclipped it from the coil. Installed new themostat back the same way.
Parts Used:
Defrost Thermostat
  • Elvin from Gardner, KS
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
9 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer not defrosting
Replaced defrost thermostat and defrost timer on my commercial Kelvinator freezer. Took out screws inside freezer compartment that hold panel at top inside freezer.Once the screws were removed I pulled out the thermostat dial so the panel was free to drop down and expose coils to the freezer that were located in the top rear of the inside freezer compartment.The defrost thermostat was located on the top of the coil to the top left as you face the inside of the Kelvinator KFS220RHY1 freezer. Very easy unplug old and plug in new defrost thermostat. Also replaced timer located in the back side of the freezer down near the middle of the bottom of the freezer near the compressor. There were two nuts holding the timer in the back of the freezer once I took those out I just unplugged the old timer and plugged the new timer in ....very simple fix. I have only run my freezer for a week since I replaced both parts but so far all is working well.
Parts Used:
DEFROST TIMER
  • Tom from Argyle, WI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Squealing noise and bottom half of freezer only froze
I removed the shelves, unscrewed the cover panel of the fan motor and regulator dial, disconnected the fan motor from power, unscrewed 2 screws holding the motor to the mounting bracket and put the new motor in it's place. New motor had no thread in the mounting holes, so I put new tread in so I could use the 2 screws. Another option would have been to drill all the way through the mounting holes and use longer screws or bolts. Of course I turned the power off before I started repairs. Freezer runs like new now. Technicians wanted $400 for the job, while it cost me a mere $55 for the Motor.
Parts Used:
FAN MOTOR EVAP 115V
  • Walter from SALT LAKE CTY, UT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
6 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The freezer was not keeping food frozen
I replaced the timer and the defrost thermostat. The defrost thermostat replacement was almost exactly like the training video here. The old part attached slightly differently. The most time consuming part was thawing out the heat exchanger, which was completely covered with ice, inside and out.

Compared to the training video, the timer took more work given its location. It was low to the ground and a bit difficult to get at around the other wires and parts. However, the new part fit perfectly. I just unplugged and unscrewed the old part then reversed those steps with the new one.
Parts Used:
DEFROST TIMER Defrost Thermostat
  • Jeffry from VERONA, WI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
6 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Would not run. Everything in the freezer was spoiled.We were on vacation when it happened so we didn't know we had a problem until we got home. Big mess.
I knew from a problem years ago that the Thermostat was the likely cause so I ordered a new part and replaced it. Only need a phillips head screwdriver to remove the part and add the new one..
Parts Used:
Temperature Control Thermostat
  • Sonya from PUNTA GORDA, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
6 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Bought a new refrigerator. Did not come with an Icemaker.
Remove access cover at bottom of case w/socket wrench (4 screws).
Attach supply line to water valve with adjustable wrench. Attach water line to ice maker on back of case (twist lock) no tools required.
Attach water line from ice maker to water valve (push connection) no tools required. Attache water valve to case at bottom w/one screw. (nut driver)
Reassemble access cover to bottom of case w/socket wrench (4 screws). Remove plastic cover inside freezer (w/screw driver to release from evap cover) to expose ice maker harness connection. Remove two plastic plugs (carefully w screw driver) exposing screw anchors for mounting Ice maker. Assemble two mounting screws w/nut driver. (Do not dtrive all the way in) Plug ice maker harness to plug on back of evap cover.(no tools required) Place cover over harness connection) no tools required. Guide water fill tube into fill cup on ice maker. (no tools required) Hang ice maker on mounting screws. Level Ice maker and tighten screws. (torpedo level makes it easy if you have one handy. Place Ice bucket under Ice maker on freezer shelf (lower position). Turn ice maker on and you are ready to go. Easy Job!!!!
Parts Used:
Ice Maker Assembly with Water Inlet Valve
  • MICHAEL from GEORGETOWN, IN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Wrench (Adjustable)
6 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
no problem just added ice maker
insatlled ic maker was very eays and fast.how ever not enouh clamps for hose;s in kit in my apinion
Parts Used:
Ice Maker Assembly with Water Inlet Valve
  • eugene a from sycamore, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Wrench (Adjustable)
35 of 93 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water Valve was leaking water and not making ice
I unplugged the fridge and unscrewed the back cover,unscrewwd the two screws holding the water valve in place and the water line to the ice maker and the electrical connection and install the new water valve,then buttoned everything back up and plugged the fridge back in and it is working great,making ice as normal.
Parts Used:
Water Inlet Valve
  • timothy from georgetown, TN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers
13 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer was freezing solid
I first replaced the defrost timer about a week prior and it did not correct the problem. I then ordered the thermostat from partselect and within 15 minutes had the part installed. My refridgerator has been running correctly for a couple weeks.
Parts Used:
Defrost Thermostat
  • Matt from Cincinnati, OH
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
6 of 7 people found this instruction helpful.