The frig was not cooling in main section or freezer
  • James M. from Belfair, WA
  • Very Difficult
  • More than 2 hours
I ordered 3 temperature Sensors Part#PS304103 and viewed the video. Got there, opened the frig. and it looked totally different and no place in any part of this frig. that took these sensors as viewed on the video. Totally baffled why these parts were listed for this frig. there was no place in this frig that would access for these part s. Serial # was HR443071.Maybe this model is out of date for these parts. Trying to find someone who can repair it. Any ideas???Purchased this GE in 2008. Model #is GSS25WSTFSS Thanks, for your help. JIM
Was this helpful?
Thank you for voting!
Refrigerator Running Warm, evaporator is not defrosting.
  • Edwin from Quincy, CA
  • Difficult
  • More than 2 hours
  • Nutdriver, Screw drivers
1. Removed and tested defrost heater, tests good. 2. Reinstalled defrost heater. 3. Removed and tested defrost over-temperature sensor, tests good. 4. Reinstalled over-temperature sensor using soldering iron, dielectric silicone grease, and heat-shrink tubing. 5. Removed the control printed circuit board and checked for blown fuse's, fuse's are all good. 6. Removed the defrost relay from the printed circuit board using soldering iron, bench tested the relay, it is good. 7. Soldered defrost relay back onto the circuit board, and reinstalled control board. 8. Removed and bench tested evaporator thermistor, the resistance is out of specification, ordered new thermister. 9. Installed new thermistor using soldering iron, dielectric silicone grease, and heat-shrink tubing. 10. Re-assembled refrigerator. 11. Installed temperature monitoring and recording instrumentation for 72 hour test. The defrost cycle is running correctly with a defrost termination temperature of around 90 deg-f. The defrost cycle ran twice while running the 72 hour test. 11. Removed test instrumentation and Put the unit back into service, The thermistor was the culprit. I bought the right part on the first shot, nice.
Was this helpful?
Thank you for voting!
defrost problem (refrigerator/freezer not cooling)
  • Gordon from Sugar Grove, IL
  • Easy
  • More than 2 hours
  • Pliers, Screw drivers
After replacing the Defrost Thermostat, Defrost Heater Assembly, and the Main Board, I concluded that the problem must be the Defrost Thermistor, which I replaced in less than 10 minutes and it fixed the problem! I cut the wires on the old thermistor and connected the new one after stripping the wires and taped the new connections with e lectrical wire. Fast and easy repair (the last part anyway ;).
Was this helpful?
Thank you for voting!
Refrigerator Fresh Food condenser iced-up. Frozen side OK
  • Dan from Decatur, GA
  • Difficult
  • More than 2 hours
  • Nutdriver, Screw drivers
Had to remove all the covers and fans to expose the condenser, which was difficult as the parts were frozen to it. The styrofoam covering the condenser made it almost impossible to defrost it. Therefore, I ripped the styrofoam off to expose the condenser. Was not really difficult to fix the styrofoam cover using metal tape. Replaced t emperature sensor in aluminum block, and used butyl sealant to secure. Had to also re-install parts of ice-ball kit that were not well covered. Lots of parts to keep track of, but anyone could do it.