Models > PFCE1NJWBDWW > Instructions

PFCE1NJWBDWW General Electric Refrigerator - Instructions

All Instructions for the PFCE1NJWBDWW
16 - 30 of 169
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Ice & Ice Cream would melt and refreeze
Noticed the problem in November 2009. Replaced Hi Limit Sesor for Defrost thinking it was the freezor temperature sensor. Did not fix the problem. Replaced Motherboard. Did not fix the problem. Called Sears Repair. They mis-diagnosed the problem and told me it was the sealed system. I doubted them and sent them home. Replaced the correct freezer temperature sensor that connects to the motherboard. FIXED.
Removed a panel, cut two wires, soldered and insulated two wries, reinstalled panel.
Parts Used:
Temperature Sensor
  • Joe from Suffolk, VA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
30 of 34 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer and fresh food compartments too warm
After having replaced the main control board and three thermistors, the fridge was still having difficulting getting cold enough - it wouldn't get colder than 15F / 42 F. Uniform frost on the evaporator coil ruled out a sealed system leak, so the remaining culprits were the either the evaporator fan motor or the compressor.

I read that a failed control board is almost always the fault of a bad evaporator fan motor, so this item was the most likely suspect.

To get to the evaporator fan motor, I had to remove, in this order:

1) Icemaker
2) Auger motor and brackets
3) Icemaker bracket
4) Freezer lights and bulb sockets
5) Evaporator panel
6) Evaporator plenum cover
7) Evaporator fan motor bracket

The greatest difficulty lay in swapping the new fan motor harness. Two pins in the harness connector were used for the evaporator thermistor.

I had to carefully cut through the old connector (using a Dremel) to extract the crimped-on pins for the thermistor, then reuse them on the new connector.

The fridge is now maintaining -5 F / 35 F in the freezer / fresh food sections.
Parts Used:
Evaporator Fan Motor Shunt Sensor
  • John from College Station, TX
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers, Socket set
25 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
I have weak thumbs
Required pliers to remove old - be careful. New went in very easily per instructions.
Parts Used:
Refrigerator Water Filter
  • Lois from Green Valley, AZ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
53 of 117 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Very high pitch whine. Not real loud but really annoying.
First I hired a repairman and he said that it was in the unit and would not be worth the expense to fix.

I started to research on the net and this was one possible source. ( evaporator fan). I had to take it apart to verify it. Then put it back together to use until the part came.

The next time went much faster as I did not have to take near as many screws out to access the fan motor. Very Happy to have it working fine again as a new relacement would cost $1200. Thanks much. Ron
Parts Used:
Evaporator Fan Motor
  • ronald from kissimmee, FL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Screw drivers
22 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer and fresh food section getting warm due to inside coils frosting over.
No self defrost. Measured heater coil with ohm meter which was OK (not open). Ordered 2 temp sensors (there are 2 in freezer, 2 in fresh food sections). The original and the new all meaured ~150 ohms. Replaced one by one. This did not fix problem. Ordered defrost thermostat. Original measured ~150 ohms - new one was ~100 ohms. Unpluged refridgerator. Removed coil panel (4 nut screws) in freezer and light cover (1 small phillips screw). Locate defrost thermostat clipped to top of coils (orange / pink wires). Cut wires and unclipped thermostat. Stripped insulation off of wires and reconnect using wire nuts. Clipped thermostat back to coils. Ran refridgerator without panel on coils to see if coils frosted up again and listend for fans/compressor to stop ( took hours). Opened freezer and viewed glow of defrost heater. Problem resolved.
Parts Used:
Temperature Sensor
  • John from Windham, NH
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Pliers, Screw drivers, Socket set
23 of 29 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The refrigirator light would not come on.
Poped out with screwdriver the old swithch and unplugged the two wires. Plugged in the wires to the new swithch and pushed it back in the hole where the old switch was before.
Parts Used:
Light Switch
  • Jania from Novato, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
24 of 38 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
My 13 yr grandson assisted me on this
We couldn't get the other connector loose from one end of the tubing so he said just cut it and so we did and attached the connector. I now have water again in my fridge and took the sticky note down "don't use the water" as it had leaked for a year...... Thanks!
Parts Used:
Union Connector - 5/16 Inch to 5/16 Inch
  • Sherry from Auburn Hills, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
15 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Switch failed on which kept the refrigerator warm due to heat generatered by light bulbs.
While the switch did last for 9 years, the design is poor due to the failure mode. The failure should be to fail off or not able to turn on the lights which would be inconvenient but would not warm the refrigerator contents. Arcing at the contacts eventually caused the switch to "weld" closed. It is not obvious that this is occurring so it took some time to recognize why the temp inside the ref was high while the freezer was OK. Replacing the switch was easy once it was recognized as the problem. All that was required to replace the switch was to remove the screws holding a fiber cover and then pulling off the aluminum cap which covered the switches. Unplug the switch an squeeze the keeper on the switch to release it and pull down. Pop the replacement switch in place and plug the wires harness back in. All in all it took much less time to replace than it has to write this up. T Pope
Parts Used:
Light Switch
  • Terry from Simi Valley, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
18 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer fan failing; veried speed making whirling sounds
First, I removed all the shelves and the light guard. Second, I removed the nuts that held the fan guard and the freezer back in place (2 just under the fan guard and removed the freezer back. Third, lifted fan guard out of way (being very careful not to crack it..... cold plastic). Fourth, unpugged fan from pug then removed nuts that held fan bracket in place...removed fan. fifth, then removed fan blade and remove fan motor from bracket, removed two wires that went to freezer light (pay attention to where they go) and installed them into the new wireing harness. Sixth, installed fan blade on new motor, bolted new assembly in fan bracket, plugged in and reistalled fan into the freezer, replaced fan guard and freezer back (reverse order of above) and then replaced freezer racks. works beautiful.
Parts Used:
Evaporator Fan Motor
  • Jason` from Colchester, CT
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver
14 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Existing light switch was hard to remove.
The existing light switch was very hard to remove. I ended up having to grab it with a pair of pliers and pull it out. Once it was out, it was very easy to put in the replacement and it seems to be working fine.
Parts Used:
Light Switch
  • Stephen from Jupiter, FL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
14 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Loud knocking noise with the evaporator fan
I had taken the noise long enough and wanted to get this repaired. I didn't want to pay a repair man hundreds of dollars to do it so i decided to do it myself. I went on to YouTube and found a few videos that showed me how easy it was to do (very helpful).

I wasn't so sure all that noise would come from the Evaporator Fan motor so i ordered it and took the chance. For the small cost, it was worth the try.

All went well accessing the unit and removing the old part. Very fast indeed. However, the snag came when i went to plug in the new part electrical to the existing electrical adapters. The old part had 4 lead connections. The new part had 6. and the wires on the new part were different colors than the existing. I had to use some logic and courage to cut the wires on the new part and rewire the old adapter to this piece. Luckily, i wired everything correctly.

Calling Part Select got me a phone number for the parts manufacturer to help with the splicing but i opted to do it on my own.

The result is i have a noiseless refrigerator again. What should have taken 10 to 15 minutes took half an hour because of the wiring but overall, very easy.
Parts Used:
Evaporator Fan Motor
  • lk from carlsbad, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
13 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken freezer light switch
Part arrived very fast as ordered..need to pry old switch out from top..use care to push the retainer down..after old switch was 1/2 out, I used a putty knife for better leveridge.Remove wire connector...after plugging in the wire connector to the replacement switch, make sure the switch is properly positioned so the switch will depress when door shuts.
Parts Used:
SWITCH LIGHT FZ
  • James from Goshen, KY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
14 of 20 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
High pitch noise
My GE refrigerator emitted high pitch noise a short while ago. I tried different dampening methods that helped but not eliminating the problem. I finally replaced the fan, motor, and associated parts and solved the problem. The total cost was about $50.
Parts Used:
EVAPORATOR FAN BLADE Compression Ring Evaporator Fan Grommet - Grey Dust Cap
  • Bert from Audubon, PA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
15 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Moving the refrigerator into my new (very old) house we had to remove the doors which resulted in a crimped hose and union
Remove lower front panel, disconnect damaged union from water hose under freezer door, replace with new union, tighten and reattach front panel. No more water coming from under the unit. Ice maker and dispenser features returned to working order!
Parts Used:
Union Connector - 5/16 Inch to 5/16 Inch
  • Laura from Manchester, NH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
16 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Switchlight was broken on tennant's refridge
as described, I used a thin screwdriver to wedge in and pull down existing, broken switch. I was able to pull it down about a 1/4 inch, but wasn't quit able to disegage it until I gripped it with pliers. I then pulled it out, unplugged the old switch, plugged in the new switch, and carefully tucked the wires back into the fridge and snapped the new switch into place.

10 minutes total.
Parts Used:
Light Switch
  • Mark from Somers Point, NJ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the PFCE1NJWBDWW