Broken Fan
Part of the fan blade broke on my AC unit and was causing a vibration. This made the AC unusable. The ordered Fan was a perfect OE replacement. I simply removed the outside over and then the fan shroud inside the unit. I carefully repositioned the condenser unit being careful not to damage the fins. Using a pair of pliers, I removed the retainer clip and removed the old fan. The new fan slid right over the shaft. I replaced the retaining clip and then repositioned the shroud. Then I placed the condenser and fins back into place and then placed the cover back over the unit. Worked perfect. No issues. Take your time. Excellent replacement fan!
Parts Used:
FAN,AXIAL
  • April from EASLEY, SC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Unit would not turn on.
1 - Unbolted a/c unit from window cover - 2 - pulled internal unit forward to reveal display and controller area - 3 - used #1 phillips to remove screws to open cover - 4 - removed display assembly by disconnecting ribbon cable from main pcb - 5 - removed old pcb from display assembly 4 small phillips screws - 6 - reused ribbon cable and temp probe in new pcb and installed new pcb into display assembly - 7 - installed updated display assembly - 8 - closed controller assembly - 9 - restored a/c unit to window frame cover - 10 rebolted connections to window cover - 11 - started a/c unit!
Parts Used:
PCB ASSEMBLY,DISPLAY
  • Tim from Chapel Hill, NC
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Bad thermistor
Took front cover off air conditioner and pulled it a little forward out of the outdoor housing. I then flipped the LED display section out to the left and exposed the patch panel. The next step was to remove the panel with a small screwdriver and disconnect the old thermistor plug. I then plugged in the new one, remove the old one from the grid bracket and placed the new one in. I then replaced everything else in reverse order. I have two LG air conditioners and they both have the same connection setup.
Parts Used:
Thermistor,NTC
  • Cindy from Baltimore, MD
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Bad thermister, unit would run constantly without cycling.
Remove the front cover. Slide the unit forward a few inches from the case. Remove 1 screw from the top on the control box. Unsnap the old thermister leads going into the circuit board. Snap in the new thermister and place the end in the plastic holder in front of the coils. Install front cover.
Parts Used:
Thermistor,NTC
  • Gary from Aurora, CO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!