[Viewing 2 of 2]Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Broken Fan
Part of the fan blade broke on my AC unit and was causing a vibration. This made the AC unusable. The ordered Fan was a perfect OE replacement. I simply removed the outside over and then the fan shroud inside the unit. I carefully repositioned the condenser unit being careful not to damage the fins. Using a pair of pliers, I removed the retainer clip and removed the old fan. The new fan slid right over the shaft. I replaced the retaining clip and then repositioned the shroud. Then I placed the condenser and fins back into place and then placed the cover back over the unit. Worked perfect. No issues. Take your time. Excellent replacement fan!
Parts Used:
-
April from EASLEY, SC
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Pliers
4 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Unit would not turn on.
1 - Unbolted a/c unit from window cover - 2 - pulled internal unit forward to reveal display and controller area - 3 - used #1 phillips to remove screws to open cover - 4 - removed display assembly by disconnecting ribbon cable from main pcb - 5 - removed old pcb from display assembly 4 small phillips screws - 6 - reused ribbon cable and temp probe in new pcb and installed new pcb into display assembly - 7 - installed updated display assembly - 8 - closed controller assembly - 9 - restored a/c unit to window frame cover - 10 rebolted connections to window cover - 11 - started a/c unit!
Parts Used:
-
Tim from Chapel Hill, NC
-
Difficulty Level:Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Bad thermistor
Took front cover off air conditioner and pulled it a little forward out of the outdoor housing. I then flipped the LED display section out to the left and exposed the patch panel. The next step was to remove the panel with a small screwdriver and disconnect the old thermistor plug. I then plugged in the new one, remove the old one from the grid bracket and placed the new one in. I then replaced everything else in reverse order. I have two LG air conditioners and they both have the same connection setup.
Parts Used:
-
Cindy from Baltimore, MD
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?