old condenser fan motor shaft was loose and it made the spinning fan blades shake and cause noise
The procedure was straightforward. I removed the cardboard backing on the lower back of the refrigerator to expose the fan unit. I then undid the electrical harness at the fan. I then removed the three screws securing the fan motor to the metal bracket. This is the hardest part in that I had to reach through and get to the screws with my small tools. I then removed the old motor and blades and placed the new motor and blades. Again, a bit tricky trying to get the three screws mounted into the bracket...small tools and hands helps. After that I used the electrical harness supplied with the kit to plug into the new motor and I was done.
Parts Used:
Condenser Fan Motor Kit
  • Christopher from Snow Camp, NC
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Wrench set
40 of 42 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No Ice, Water did not fill icemaker
We weren't sure if the problem was in the Water Inlet Valve or in the Icemaker Control & Motor Assembly. The water in the door did work. We removed the Water Inlet Valve & tested it with an Ohm Meter. It tested good so we put it back in. We then ordered the Icemaker Control & Motor Assembly. When it arrived we installed it and waited a few hours but the icemaker still did not fill with water. We telephoned a parts store and were told the problem could be the thermostat or we could replace the whole icemaker. We replaced the whole icemaker.
Parts Used:
Icemaker Control Assembly
  • Barbara from Davenport, IA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Screw drivers, Wrench (Adjustable)
45 of 59 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light Switch broke
An easy job for smaller hands. Removed the two bolts holding the light cover. Removed two electrical connections from the old switch by pinching the retaining clip,removed the switch, snapped in the new one and re-attached the connectors. Your online illustrations helped me to know that the plastic housing for the light switch would only swing down so far and was not intended to be removed. Saved me from breaking that plastic cover's tabs. This home repair saved me more than 5 times the cost of hiring a professional to do it. Very happy homeowner.
Parts Used:
Refrigerator Door Switch
  • James Richard from St. Cloud, MN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Socket set
44 of 60 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Scratches in Surface
This product comes in a bottle with a brush like Liquid Paper. It goes on incredibly easy. A second coat might be needed. I wanted to prevent rust from setting in so I covered the scratches and dings. The paint is a little brighter since my washer is 10 years old but it still looks great.
Parts Used:
Touch-Up Paint - White
  • Michelle from Richardson, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
65 of 128 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The ice maker stopped producing ice.
If you remove the bottom vent panel of the refrigerator there are two schematics for the refrigerator. One for the fridge and one for the icemaker. The icemaker has an emitter and a receiver that will tell the icemaker when it is ok to dump ice and add water. The receiver has an LED that blinks different codes. The codes give you an idea where your problem is located. In my case it coded out to be the optics (emitter and receiver). Replacement of the parts involves the removal of three screws on each component and disconnecting a wire harness on each component. Install the new components by following the removal process in reverse. The total cost was $80.00. This was half the price Sears wanted for the parts and about the same price to have a Sears repairman just show up at the house.
Parts Used:
CNTRL-ELEC
  • Robert E. from Payson, UT
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
34 of 36 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator Wasn't Cooling,Evaporater Coil Freezing Up
I have a side by side so in order to access the bi-metal switch I first had to empty out the freezer. The switch is clipped on to the top of the evaporator coil. I had to remove 8 screws to remove the back panel of the freezer compartment. The bi-metal switch was right there in plain view. There are two colored wires that come out of the switch. I tried pulling them out of the socket they were plugged into but gave up for fear of breaking something. I ended up cutting the wires and splicing them together. I used the plastic twist caps. I made sure when I closed everything back up that the open end of the caps were pointing down so no water can accumulate in them. It has been 3 days now and so far so good
Parts Used:
Bi-Metal Defrost Thermostat
  • Robert from Doral, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
38 of 50 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Auto Defrost Freezer keeps defrosting SIDE BY SIDE KITCHENAID
DISCONNECT POWER. Removed all shelves/baskets.Popped upper panel off (just clips in) Removed 6 screws in lower back panel ( 3 each side) slid panel in place but down. You can then easily see the defrost thermostat/defrost termination switch. Cut the wire connectors (pink n brown wire) stripped back wire, attached new defrost thermostat. Thermostat clips on. New thermostat ohm's at 5.5, old one was "open". Slid cover back up meeting the upper cover grooves. Screwed lower panel in. Put shelves etc back in. Plugged in. Turns on, put a bottle of water in freezer. Checked a while later, frozen. has been frozen for a week.
-James
Parts Used:
Bi-Metal Defrost Thermostat
  • James from Ringoes, NJ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
37 of 47 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The icemaker stopped filling the ice tray to make ice.
I checked the fuses and hoses in the back of the refrigerator to make sure water WAS in fact getting to the front of the fridge. Since the water through the front door worked fine, I had to check the water tube running to the ice maker. It was fine and water was waiting to go somewhere! I decided to pull the icemaker out of the fridge to see what I could fine. Once it was out, I took the ICEMAKER CONTROL AND MOTOR ASSEMBLY off (that's the side part with the dial on it). Only 3 screws to take that off, and it was EASY to see what was wrong once I took that off. There was a connection that was obviously bad (looked almost like it had burned out). My thought was that it was obvious what part was bad, what would it hurt for me to try to fix it myself? When I got online to find the part, PartSelect was the only one that I found that had the EXACT part that I needed, and lucky for me, there were multiple pictures of multiple angles of the part so I could compare and make sure I had the right one!! The part with shipping cost less than the cost of a repair tech to even come out and look at the fridge. Then add the cost of the part and labor if I had the repair tech fix it...I probably saved about $250!!!!
Parts Used:
Icemaker Control Assembly
  • shannon from sierra vista, AZ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers, Socket set
32 of 37 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
no electricity going from inverter to compressor
pulled out inverter box, opened up and located burned components in circuit board. rolled the dice bought new one and installed. the terminal leading from inverter didn't match the terminal coming from the compressor . cut both off and supplied my own junction terminal.
Parts Used:
Inverter Board
  • s. from fort lauderdale, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
42 of 71 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The black plastic or teflon coating on the ice mold was coming off in flakes and freezing in the ice cubes
I took out the ice collection box and auger to get access to the three screws holding the ice maker assembly against the left wall of the freezer. You can use a screwdriver or a nut driver. I then unpluged the assembly and wiggled it loose from the water fill tube. I assumed that unplugging the unit would disable the water valve but I put a plastic tub under the fill tube just in case. I studied the assembly on the kitchen table for a few minutes before I disasembled it. After removing a snapon plastick cover I removed three or four screws on the gearbox and was able to pull and wiggle the parts apart. The heater contacts have rubber O rings so you have to be firm pulling the mould out of and into the gearbox mount. Make sure it is fully seated. On reassembly note that the ice kicking arm is notched so it fits into the gearbox only one way and it helps to have it in position when you screw the gearbox back on. I also found the plastic ice guide that fits on top of the mold a little awkward in snaping back together. Make sure its fingers space evenly with the ice kicking arms.
Parts Used:
Ice Mold
  • Roger from Sunnyvale, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
32 of 42 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker mold was cracked and leaking water into the bin which then froze all the cubes together.
I removed the ice maker assembly from the freezer compartment (four nuts/ nut driver) and unplugged the wire harness. I discovered the nature of the problem and I went on the Internet to look for replacement parts expecting I'd have to buy the entire ice maker. When I found PartSelect.com I looked through the pictures of the parts available for my ice maker. I found the correct part quickly and easily. And having an acurate photo on the site, I was able to match all the key features of the mold I had with the one on the screen. I ordered the part, and installed it the day it arrived with just a Phillips screwdriver and a nut driver. It functions perfectly.
Parts Used:
Ice Mold
  • George from Cottage Grove, MN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
28 of 30 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Had to replace a hose connector at the base of my refrig/frreezer
Perhaps a helpful hint:

When aI received the hose adapter/connector, I inserted the 2 hose ends only to have water drip from the connection.
I used a utility knife to remove an inch from each side, then reinserted the hoses. That made the differnce. Dry as a bone.

LG
Parts Used:
Water Tube Connector/Union - 5/16 to 5/16
  • Leo from Salem, SC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
43 of 76 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Icemaker arm was broken
The tiny piece of plastic that holds the wire that shuts off the icemaker, broke early on with our fridge (after just a few months.) We superglued it, but last week it bit the dust for good.

Once I got this part, I removed the freezer door and trays, and pulled the icemaker out by removing 3 flathead screws and unplugging the cables. Laying in the freezer on the floor was a bit unconfortable, but not too bad.

Then I inspected the icemaker. There was no obvious way to remove the part without disassembling the front of the unit (where the motor is) to release the spindle and free the part, so I did that - 3 or 4 nuts was all that held it together. Once that was out, I removed the spindle, swapped out the part, and put it all back together and back in the freezer. Plugged it in and waited.

It took a while to start making ice. Like 5 hours. Now it's going pretty slow (much slower than before.) Haven't had time to look into it, but my suspicion is the rubber hose that feeds water into the icemaker is blocked with ice or kinked. In any case, we have ice now (but not a lot), and the unit shuts itself off properly. However, we went from having too much ice (thing never shut off) to too little (thing makes ice too slow), so I need to shoot for somewhere in the middle ;)
Parts Used:
Water Fill Cup and Bearing
  • Jason from Austin, TX
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
32 of 44 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water Filter needed to be replaced
It was SOOO easy, I turned and popped out the old filter and turned and snapped in the new one....I don't even think it took a whole minute to replace!!
Parts Used:
Whirlpool EveryDrop3 Refrigerator Water Filter
  • Leslie from Nipomo, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
32 of 44 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
My ice maker stopped producing ice. It would dispense ice that was already made and the water dispenser worked.
I looked at some online diagnostics info and the owner's manual. The "error code" blinking red light on the receiver unit (located adjacent to the ice bucket) indicated that the emitter/receiver units were faulty. I located the parts on the PartSelect website (their price was less than half of what they wanted on the Sears website) and ordered them. I didn't pay for the expedited shipping and still received the parts within two days of ordering. Powered down the refrigerator, three simple screws to remove each cover for the emitter and receiver, unplug the old units and pop in the new units, replace the covers for each unit, repowered the fridge and, voila, you've got ice. I completed the repairs in less than 10 minutes. Couldn't be happier with the price, the diagnostics links/info or the prompt service. Next time I have an appliance issue, my first stop will be this website.
Parts Used:
CNTRL-ELEC
  • Glenn from San Marcos, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
26 of 27 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!