Microwave wasn't heating up foods
Per instructions on part select.com website. But needs further repair because still doesn't heat food and pad is partially disabled.
Parts Used:
Diode
  • William from LAKE ELSINORE, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave would turn on when door opened
Unscrewed numerous screws holding the "body/shell" to the microwave. Removed body. I then unplugged top door switch, replaced it with new one, and "tested" the new one. I fixed our $400 convection micro with an $18 switch. NICE!
Parts Used:
Secondary Door Switch
  • Lois from El Segundo, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Left light socket was damaged beyond repair
Handed the part to my son. He unscrewed 5 screws in the base of the microwave, it dropped down. The light mechanism was clearly in view. With the exception of some corrosion on the old piece, it was simple to remove and replace, put back together, screw back up and all worked fine.
Parts Used:
Light Socket - 250V 75W
  • Kathleen from Streamwood, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave ran, but wouldn't heat
I thought the thermal cutoff was out, ordered a new one. Turns out the TCO I was looking at was normally-open, and closes if overheated. My advice: No matter what your microwave is doing, start with a full inspection of each of the door switches. I did a continuity test, which initially passed; after replacing TCO didn't fix it, I found that one of hte door switches was intermittent - it had failed mechanically, would appear closed if jostled just right. After replacing that door switch the problem was fixed. Next time I'll start with the door switches - they're the easiest part to find, coulda gotten it locally - is most likely to fix the prob, and if not at least you've ruled them out for future troubleshooting.
Parts Used:
Magnetron Safety Cut-Off
  • Lewis from HGHLNDS RANCH, CO
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Inside Bulb went out.
Remove top air grate via 2-screws. Remove metal top panel behind grate that's above bulb via 1-screw. Bulb is exposed and can be un-screwed. DONE
Parts Used:
Light Bulb - 40W 130V
  • Richard from Austin, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Bulb broke in socket, socket had deteriorated beyond repair.
Phillips screws on bottom panel allowed me to install new socket and put electric connection back. Secured bottom panel and that was it.
Parts Used:
Light Socket - 250V 75W
  • Frank from CICERO, IL
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave wouldn’t shut off when door was opened
Followed the online videos to enter the cavity to the switch holder. Noticed right away the dreaded capacitor was in back right corner behind where the touch pad had been removed. I isolated the capacitor with an old computer mouse pad for extra safety. Took some manipulations to get the switch mount out from behind the wire bundles. Once out front, easy to use small flat blade screwdriver to release each switch and replace with matching new switch. Only one switch was bad but replaced all three. Back together and working great.
Parts Used:
Monitor Door Switch Secondary Door Switch
  • John from POWHATAN, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Total power loss of microwave
GE slate microwave approximately 2 years old. Completely dead. Power to outlet was good, no gfci was tripped. Started checking fuses, 250v ceramic fuse good, two fuses at the bottom behind the control panel. One on the left labeled 12 on the diagram tested no continuity. One on the right labeled 13 tested good with continuity. So i figured number 12 was bad. Got the part and turns out to be the wrong fuse. Part number was the same but the terminals were the wrong size. Im pretty sure GE has the diagram labeled wrong because i ordered number 13 and it was the right size. Just an FYI if you are ordering those fuses for your microwave that 12 and 13 on the diagram may be reversed. Anyway received the right fuse and tested the new fuse and it tests open continuity and did not fix my issue. Microwave is still dead. There are two other fuses in the back that i need to check so hopefully i find the issue. Hope this helps someone, remember one fuse behind the control panel tests open and the other tests closed and thats how it is suppose to function.
Parts Used:
Vent Thermostat
  • Jason from SHEFFIELD LK, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
screen quit working
I first ordered the Board, wrong part. The person I talked to was very nice and helpful. He said send board back in and he would send me the correct part. I received the touch pad and control panel in a few days. One screwdriver, 3 screws put the board on the control panel put back in place, done deal. Microwave working again.A friend told me where to look on internet and find Parts Select.

Joey Bird
Parts Used:
Control Panel - Black
  • Joey from SEVIERVILLE, TN
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
bulb fused to jolder
removed electrical wires, unscrewed holder, inserted holder, attached wires, added bulb, and put cover back on.
Parts Used:
Light Socket - 250V 75W
  • James from Big Rock, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Glass was broken
I took the cover off, and replaced the glass-- the difficult part, was ordering the glass..on the list of parts to order-- the description of the glass was mis-leading
Parts Used:
Light Cover Frame
  • jerene from Houston, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
10 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light bulb burned out and assembly broke when trying to replace bulb
I used the internet and your directions to complete the repair. It was easy!
Parts Used:
Light Bulb - 40W 130V Light Socket - 250V 75W
  • Jeanne from Kirkwood, MO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
chattering noise/ burning smell
Removed control panel disconnected old capacitor installed new and returned the leads back on to the new. replaced control cover and tested
Parts Used:
High-Voltage Capacitor - 2100V
  • James from Enfield, CT
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
4 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
2 rack holders broke
used the Dremel Osciilating tool with small blade to quickly cut/remove the old rack holder and then inserted new hold. Took less then 5 minutes total.
Parts Used:
Rack Holder
  • Nick from Edison, NJ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
5 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Unit would run when door is opened
Two screws to remove upper from vent. Two screws to remove the didgit panel lift ip to remove and put aside remove the two screws that hold the door sensors. Depress the tab to remove the defective sensor disconnect the electrical connector and replace the new sensor snap it back into the holder install the two screws, install the didgital panel and vent panel to complete the job. Please be aware that there is a video of this procedure on Y tube
Parts Used:
Monitor Door Switch
  • Ernest from RIVERSIDE, CA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!