Glass Carousel Cooking Tray Broke
I replaced old tray with new. Received replacement part in two days. I was surprised at the quick response time. The part ordered was right the first time.
Parts Used:
Cooking Tray
  • selwyn from inglewood, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave appeared to work. Fan worked, timer worked plate rotated. It just didn't heat the food!
I purchased the fuse and 3 door switches from PartSelect. Replaced the fuse first but that did not solve the problem. Then I replaced the 3 door switches and problem solved!! So fuse only cost $5.00 so glad I have a new fuse in there as well. To see how to replace door switches see videos on utube!!
Parts Used:
Secondary Door Switch
  • Mark from Hanover Park, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
7 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Turntable drive moter making ratcheting sound
Removed power from unit. Removed 7 screws from cover on bottom of microwave. Unplugged the power connector from the installed motor. Removed 2 screws holding motor. Positioned new motor using small nibs used for purpose of proper positioning. Used mounting screws removed from old motor to firmly fix new motor in place. Installed original mounting screws holding bottom cover in place. Connected power and tested operation.
Parts Used:
Turntable Drive Motor
  • Stan from LOS ALAMOS, NM
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave would turn on when door opened
Unscrewed numerous screws holding the "body/shell" to the microwave. Removed body. I then unplugged top door switch, replaced it with new one, and "tested" the new one. I fixed our $400 convection micro with an $18 switch. NICE!
Parts Used:
Secondary Door Switch
  • Lois from El Segundo, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Glass carousel cooking tray shattered
It took less then 10 minutes to order. Received new part with 3 days
Parts Used:
Cooking Tray
  • Susan from Marco Island, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The cooking tray cracked.
First I replaced the cracked cooking tray and I was done.
Parts Used:
Cooking Tray
  • William from Columbus, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave wouldn’t shut off when door was opened
Followed the online videos to enter the cavity to the switch holder. Noticed right away the dreaded capacitor was in back right corner behind where the touch pad had been removed. I isolated the capacitor with an old computer mouse pad for extra safety. Took some manipulations to get the switch mount out from behind the wire bundles. Once out front, easy to use small flat blade screwdriver to release each switch and replace with matching new switch. Only one switch was bad but replaced all three. Back together and working great.
Parts Used:
Monitor Door Switch Secondary Door Switch
  • John from POWHATAN, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Unit would run when door is opened
Two screws to remove upper from vent. Two screws to remove the didgit panel lift ip to remove and put aside remove the two screws that hold the door sensors. Depress the tab to remove the defective sensor disconnect the electrical connector and replace the new sensor snap it back into the holder install the two screws, install the didgital panel and vent panel to complete the job. Please be aware that there is a video of this procedure on Y tube
Parts Used:
Monitor Door Switch
  • Ernest from RIVERSIDE, CA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dropped and broke the cooking tray
New one arrived very quickly.

Right part. Right on time. Fit like it should.

Excellent service.
Parts Used:
Cooking Tray
  • DAVID from IRVINE, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
4 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dropped and broke glass carousel tray
Put it in place. Ordered replacement over internet on Wednesday and part arrived Friday. Very fast service!
Parts Used:
Cooking Tray
  • Eugene from Lakeland, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken
replaced
Parts Used:
Cooking Tray
  • Janet from Fort Worth, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
When door opened, microwave would turn on
Removed the outer cover to access the door switches. Turns out there were three switches, but I determined that only two were bad. When the small colored tab on the switch is pushed in it should make a clicking sound. The two bad switches had no resistance and did not make any noise when pressed. Removing the switch is relatively easy, you simply pull it away from a couple small tabs holding them in place. After reconnecting the wire leads, insert back into the holding tabs and install the cover.
Parts Used:
Monitor Door Switch Secondary Door Switch
  • Tom from SUN PRAIRIE, WI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The microwave turntable rotates when the door is open.
This is sometimes described in other repair notes as "microwave 'runs' when door is open."
With power disconnected: Remove the microwave's metal grill surround. Three lower screws accessible with lower oven door open. Two screws accessible at top of microwave door opening with door open.
Remove microwave control panel: Remove two femaleTorx head screws (#27?) that secure the panel, accessible at right side of door opening. The right side of the control panel is secured by plastic tabs fitting into slots in the oven frame. Take good care to note how these tabs disengage from the slots (lift and shift). Tab breakage very possible! Once disengaged, the panel hinges outward and downward and is self-supported. It may be necessary to guide some of the wiring out of the way to fully lower.
There are three door switches, one "monitor" and two "secondary" switches. All switches are housed in a plastic frame, which must be lifted out of position for access, each switch is retained by flexible plastic, breakable-looking hooked fingers. Also note that the electrical connectors have tiny release tabs that must be depressed in order to pull them off of the switches. In my case the topmost switch, one of the "secondary" switches, was clearly bad since there was no "snap" or click when pressing the switch's button. Maybe you can determine which switch is bad before proceeding but I had ordered all three to avoid going through this exercise again any time soon.
Replace switch or switches, place switch carrier back into position and otherwise reverse the disassembly steps.
Parts Used:
Monitor Door Switch Secondary Door Switch
  • DeWitt from Boulder, CO
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Bad thermostat
Removed outer case, checked fuse first, it was good so went to thermostat. No continuity reading. Unhooked thermostat, used jumper wires to by-pass break—briefly plugged the unit in. It came on so I knew the issue was definitely the thermostat.
Parts Used:
Thermostat
  • John from COVINGTON, GA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Still runs even the door was open
Pulled it from the wall remove the front vent covers removed the control panel remove the door switches by a special screw driver bit which looks a star remove the electrical terminals pressed the plastic clip pulled the switch replaced it with new one then followed initial steps backward
Parts Used:
Monitor Door Switch Secondary Door Switch
  • Erwin from CONROE, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers
2 of 3 people found this instruction helpful.