Twice I ordered the oven light bulb & each time the light bulb was defected
I had to call for a appointment for repair with GE Appliance because I thought then it . .was something electrical. The technician came out & checked everything out, turned out it was not electrical, The technician went out to his truck got a light bulb from his truck, put it in & it worked. It cost me $121.00 for trip charge from GE appliance for a light bulb that worked, your light bulbs were defective twice. Very disappointed with your products, cost me alot of money for a good light bulb thru GE appliance
Parts Used:
Light Bulb - 40W
  • Barbara from BELLEVUE, WA
  • Difficulty Level:
    Very Difficult
  • Total Repair Time:
    Less than 15 mins
17 of 34 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer intermittently thawing and refreezing.
Local repairman was called. He replaced the condenser fan motor as it had an intermittent noise several days before. Cost of the repair was 252.00. Two days later freezer was thawing again. He then came back again and said it was probably the evaporator fan and would replace it for 339. dollars or the mother board which he would replace for 500 dollars. He recommended replacing the unit. Since my unit was still in pristine looking condition I decided to do some further research. That is when I found your web site. After reviewing the possible causes on your site I ordered the defrost themostat and and all three thermistors.As a precaution I also ordered the evaporator fan and defrost heater and bracket Assembly. When the parts arrived I disconnected the power to the unit. Removed the shelves and lower pan. Removed the light shield and light bulb. Reovede the two screws holding the evaporator coil cover. This allowed access to the evaporator themostat. I then cut the wires from the old themostat and removed it from the coil. I then stripped the wires on the colored wires and also cut the wires on the new themostat and stripped those. Then using wire nuts I aatached the wires making sure they were properly color coded. Wrapped with electrical tape and attached the new thermostat to the evaporator coil. I then located the evaporator temperature sensor and removed it from the coil and removed the clip and placed it aside for use on the new sensor. I cut the wires and discarded old sensor. Stripped wires on the new sensor after determining the proper length and stripped the wires where the old one was removed and the using in line connectors I first crimped the wires on the new connector and the crimped both wires to the wires previously cut and stripped. Reinstalled the connector to the clip and clipped it back onto the evaporator coil. I then disconnected the wires attached to the defrost heater bracket assembly, located the two screws holding it to unit and removed it from the unit. I did a continuity check on it and it checked ok but was black so I replaced it as a precaution since I already had a new one. Hung the new unit onto the mounting bracket reinstalled the two mounting screws and reattached the two wires. Reinstalled the evaporator cover making sure to reattach the ground wire clip. Reinstalled screws and light cover and all shelves and pan. Reconneceted electrical power. Unit operated fine for a couple of days and then thawed again. I then retraced the steps removing what I had to remove to replace the evaporator fan motor and replaced it per the installation instructions on your site. The unit has now been operating for five days maintaining -8 degrees in the freezer and 37degrees in the refrigerator. I probably could have done a little more trouble shooting at the main board but didn't want to risk damaging that since I already had the parts I thought would fix the problem if it wasn't the main board. I only replaced the one temperature sensor so I will probably return the two I did not use. Thanks for your excellent "how to"videos.
Parts Used:
Evaporator Fan Motor Defrost Heater and Bracket Assembly
  • Donald from HAINES CITY, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers, Socket set
9 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Dispenser not working
As it turned out much of the electronics is driven by 13.5 volts off the Main Control Board. The Ice Dispenser caused the problem because it over currented the depleted board power. You could hear a clicking noise from the board which was the main relay short cycling and not staying energized. While waiting for the replacement board I unpluged the condenser fan which is a DC motor and uses the Board power. In place of that fan I use a small table top fan to keep the condenser cool. As it turned out I only needed it for 3 days because Parts Select did a super quick job of delivering the new board. Thanks for the super service!!!!!! Removal of the board only required unpluging the electrical connections squezing the retaining board pins with pliers and pulling the board out, pushing on the new board and connecting the electrical plugs. If the board locks like mine did, just unplug the main board power plug, let the memory clear and replug the power plug. The unit should then start and run with no problems.
Parts Used:
Main Control Board Assembly
  • David from Boca Raton, FL
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
9 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fresh food section lights were all out, but the bulbs tested good elsewhere.
I popped the switch out using the blade of a small screwdriver and noticed that it connected with two wires via a slide on connector for each one. I noted the info on the old switch to identify which wire went to which terminal. I held each wire with a pair of pliers while I pulled the wire connector off the terminal on the old switch. I connected the two wires to the correct terminals on the new swith, and popped the switch back into the door frame. Easy, easy, easy and saved the $40 service call + parts cost!
Parts Used:
REFRIGERATOR DOOR LIGHT SWITCH
  • EDWARD from INDIAN WELLS, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
8 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Icemaker flap not closing, frosting up
Watched video, however could not get outer casing off. Under the panel are three small holes, pushed up with an Allen key, used a small screwdriver to wedge out, came out easily, followed instructions from video on removing and replacing solenoid
Parts Used:
Dispenser Door Solenoid Assembly
  • Graeme from Sarasota, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
9 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridge not cold
On this fridge, you MUST take out the ice maker. First took out the shelves. Then take out the ice maker. This is done by taking out the four screws on the side that hold the assembly containing the bulb. Then there is one screw that holds that assembly to the icemaker. Do not take out any other screws, this is a mistake I made that cost me a few more hours figuring out how to get the other parts to mount correctly to the assembly containing the bulb. The icemaker should lift right out once the white plus is unplugged from the assembly that holds the light. Then took out the shelf brackets and finally could remove rear panel. Found it all iced up as others have. Took 1.5 hours to manually defrost while using sponges to sop up all the water that would run into the drain if you let it. Was about a gallon of water so using sponges worked well. Heater was open when checked with a meter, but you could tell it was blown by the way it looked. All cloudy. Put things back in reverse order. Had an issue with the icemaker shooting water out and missing the icemaker. Eventually was able to align better. This fridge had also just stopped dispensing water. I think the lines may have been frozen in the back, because one day after defrosting manually, the water dispenser started working again Overall this took about 4 hours. But a few days later, the water dispenser again stopped working. Not sure about that one. I have a valve already that I will try for this issue but somehow I don't think its the valve.
Parts Used:
Defrost Heater and Bracket Assembly
  • Christopher from Perkasie, PA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
9 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Drive cup broke, light went out
Just had to pull ice maker drawer out and replace the drive cup which was very simple. Light bulb on door dispenser was kind of hard to get back in cause it is such a small space to screw the bulb in.
Parts Used:
DISPENSER LIGHT Ice Dispensing Drive Cup
  • Stella from Puyallup, WA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
14 of 27 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice buildup. The Ice Machine was frosting over. Ice (due to frosting) would block the drop chute.
Unfortunately, the replacement part didn't come with instructions. The repair, nevertheless, was fairly straightforward. After removing the plastic parts that guide the ice through the door (by removing a few screws that attach the parts to the inside of the door), I was able to slip my hand into the ice maker dispenser and remove the old part. The part clips on. It is a tight fit through the funnel (from the outside of the freezer), however, and requires that the gasket first be "flipped" open wherein it unfolds 180 degrees. Doing this will make it easier to clip the new gasket onto the assembly.
Parts Used:
Dispenser Door Assembly or Flapper
  • Tim from The Woodlands, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
9 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
door stop broken from fatigue
using a small socket wrench and star shaped driver I (1) removed the two screws that held the broken stop from the bottom of the door, and (2) replaced the new stop and screwed it back in. The most difficult part of the job was opening the door in order to access the second screw.
Parts Used:
Door Stop - black
  • Darrell from Long Beach, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Socket set
11 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker door not opening
Removed panel from front of freezer door by pushing up on three spring loaded screws located in the opening where the ice door opens and closes. they are about 1 inch apart on the bottom of the opening. Push up to free ice maker panel. Remove three screws from solenoid, located at the top right. Remove wire, replace with new and that is it. Fixed the problem!! Our ice maker hadn't worked for months. Be careful if you remove the round ice maker door to clean. There is a spring that located on the left side of sprocket. The spring fell off and took me a while to figure where it came from. Recieved package in three days and the job took minutes. Works great! Very easy to complete.
Parts Used:
Dispenser Door Solenoid Assembly
  • scott from lake orion, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
8 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
replace split shelf with solid one
The slideout shelf "assembly" comes without the
keeper tab, and as such is incomplete. You have to order it separately or rob it from the old one. If the old one is broken or you break it trying to get it out of the old one you're out of luck unless you ordered
the tab also. Other than that it's a no-brainer.
Parts Used:
Slide-Out Shelf
  • James from Powell, TN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
8 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
glass panel cover/glass cracked
First, I removed the top drawer blocking the area where I needed to put the glass panel cover. Then, I removed the drawer along with the glass panel holder to which I needed to install the glass. I installed the glass to the panel holder without difficulties (although the glass cover was expensive :() and reinstall the drawers back to their proper place. This repair was actually a no-brainer.
Parts Used:
Pan Cover Glass
  • Jo Anne from Walnut, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The eavporator coils were completely frozen which prevented fridge-freezer air circulation
1. Removed all food, shelves, and ice bin from freezer compartment.
2. Removed freezer light hood and unscrewed freezer bulb.
3. Removed rear evaporator cover panel (2 Phillip’s screws, 2 hex screws).
4. Melted ice on coils with hair blow dryer (needed bath towels to collected water).
5. Removed old defrost heater (2 Phillips screws, 2 plug-ins).
6. New heater connected without any adjustments.
7. Replaced evaporator cover ice bin, shelves and food.
Parts Used:
Defrost Heater and Bracket Assembly
  • chris from GROVE CITY, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken Door Stop
Suggest removing black plastic grill first to gain better access to door stop screws. The grill is attached by two phillips screws, one on either end and several metal spring clips in the middle. The door stop is held by two star shaped screws that are only visible with a mirror. Suggest using a bit attached to a small ratchet.
Parts Used:
Door Stop - black
  • Mark from Stuart, FL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
11 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator side freezing food
Replaced both temp sensors worked good for 2 days then began freezing food. Looked into it further on line. Found small motorized door broken that controls the cold air from the freezer
Parts Used:
Temperature Sensor Shunt Sensor Refrigerator Temperature Sensor Cover
  • M &M Aviation from ESCANABA, MI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!