condenser motor broke
  • patrick from livonia, MI
  • Easy
  • 15 - 30 mins
  • Nutdriver, Pliers, Screw drivers
opened box,read directions,took out bad motor,installed new one.PRESTO CHANGO way to go.
Was this helpful?
Thank you for voting!
Door Latch broken
  • Eugene from Arlington, TX
  • Really Easy
  • 15 - 30 mins
  • Pliers, Screw drivers
Ordered part ( door latch ) flowed instructions easily fixed same.
Was this helpful?
Thank you for voting!
Freezer was not getting cold enough
  • David from Salem, WI
  • Easy
  • 15 - 30 mins
  • Nutdriver, Pliers
Mine was alittle different than the online instructions. 1. I removed the motor. 2. I took the fan off the old motor and cut the wires about 3" back from old motor. 3. Mounted the new fan on bracket and put the fan on the new motor. 4.connected wires that were cut and used wire nuts to connect. 5. Mounted bracket and motor/fan to unit and it works like its brand new. Thank you PartSelect!
Was this helpful?
Thank you for voting!
Condensor Fan going bad
  • George from Hickory, NC
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Pliers
I knew the repair wasn't difficult. It was a matter of finding the replacement part. Luckily, I found the part via the internet on your site. Lucky for me, there was an installation video!! These videos are worth 1000 bucks!! Never have encountered a site with installation videos before. It gave me complete insight as to how the job was sequenced. I'm a very visual person, so videos are the perfect helper for me. With fewer and fewer affordable local service companies around to fix problems like mine, your site gave me the complete confidence to easily switch out the condensor fan. I completed the repair for about $63.00. Your site ROCKS! Keep up the repair videos because they are awesome and extremely helpful. I felt like your pricing was competitive for this item. Thanks again!!
Was this helpful?
Thank you for voting!
Condensor motor was frozen
  • john from thibodaux, LA
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Pliers
pull unit away from the wall, and unplug it. remove the grill, and cardboard guard on the lower back of the unit. remove Three screws for the motor bracket. Remove the bracket legs from the old motor and assemble them to the new motor. take the fan blade off the old motor, place it on the new. Cut the wires at the old motor, strip th e insulation back, use supplied wire nuts to connect the new motor. Reverse order to reassemble. Plug in unit to test function.
Was this helpful?
Thank you for voting!
condenser fan wore out
  • Nancy from Gallatin, TN
  • Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
The kit I recieved was perfect. All parts fit and where a perfect match. I will give you an A+ in handling my order and shocked by speed of your delivery.
Was this helpful?
Thank you for voting!
Condenser motor stopped working
  • Chris from Greenville, OH
  • Easy
  • 30 - 60 mins
  • Pliers, Screw drivers, Socket set
Removed bad motor with socket set and pliers then removed the connectors from the old motor and soldered them on the new one. Then installed new motor. Works like new! Problem Solved! Easy fix!
Was this helpful?
Thank you for voting!
Freezer was icing up and
  • Benton from Vancleave, MS
  • Very Difficult
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
Ordered timer-defroster motor and replaced. Very difficult to remove the two screws since there was little room to apply the tools.
Was this helpful?
Thank you for voting!
intermittent loud whirring noise
  • Honz from Tucson, AZ
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver, Pliers, Socket set
Moved fridge out from wall, unplugged power cord. Laid on floor, removed 6 screws from cover. Removed one threaded bolt to allow assembly to slide out. Removed special nut, and took fan off. Removed 3 motor mounting bolts. Unscrewed 2 wire nuts, and untwisted wires. (option 1, no ground) Vacuumed entire area around motor. Used 3 bo lts to mount motor to holder assembly, and special nut to install fan. Stripped wires back about 3/4 inch. Twisted two wires together CW, and installed new wire nuts. Slid motor assembly back into slot,(keep wires away from blades) and used one threaded bolt to secure assembly. Reinstalled cover plate with 6 screws. Plugged power cord in to test air flow (out through cover vents). Moved fridge back into place. The loud whirring noise did not stop for a day; then quiet!
Was this helpful?
Thank you for voting!
Frozen Lettuce In Crisper
  • Mary E. from Chicago, IL
  • Really Easy
  • 30 - 60 mins
  • Screw drivers, Socket set
My husband put in in, no problem and all is well. My husband is a mechanic for large machinery/motors so installation was no problem. Thanks, better than buying a new fridge!!!
Was this helpful?
Thank you for voting!
The freezer compartment was not cold enough.
  • Tom from Paducah, KY
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers
I found the condenser fan was not working so I bought a new condenser fan kit and installed it. Fixed!
Was this helpful?
Thank you for voting!
Door catch broken
  • Martin from Grapevine, TX
  • Really Easy
  • Less than 15 mins
Push new catch in the opening, close the door and VOILA! the door stays closed. Please note that the cost of this part is exorbitant- it's worth about 50 cents but with shipping it cost about $11.00. Check your local hardware store first.
Was this helpful?
Thank you for voting!
broken door catch: female half
  • Allen from Seattle, WA
  • Really Easy
  • Less than 15 mins
noticed that male half was in good working order, so I just snapped in the new female half; without any tools. easy repair!
Was this helpful?
Thank you for voting!
Male door latch would no longer catch.
  • Joan from North Myrtle Beach, SC
  • Really Easy
  • Less than 15 mins
  • Screw drivers
After ordering the part, I read the information left by other users. I used a screw driver to pop out the piece, and then put the new latch in the opening. A gentle pop with the side of my hand, and the door latch went right into place. Who knew there was a second door latch on the other side that could've been used?
Was this helpful?
Thank you for voting!
refridgerator was not cooling to the proper temps and finally would not cool at all
  • John from LAS CRUCES, NM
  • Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
Pulled refridgerator forward away from the wall. Remove the cardboard back behind the appliance.I saw that the condenser fan motor was not working. Unplugged the appliance from the electrical outlet. Removed a 3 wire plug from the condenser fan motor. Remove 3 screws (with a nut driver) which held the condenser fan motor in place. Remove the condenser fan motor from the appliance. Looked up the part needed for repair using the appliance model number. Found which part was applicable for the appliance. Placed the order from Price Select on a Monday morning and recieved the part 2 days later on Wednesday via FedEx. The item shipped was a 2 wire condenser fan motor. Read the instructions that came with the part. Using wire cutters, cut the old 3 wire plug. The center wire is a green and yellow striped wire. Use the same colored wire that is also shipped in the box and has connectors on both ends. Cut one of the connectors off and use the wire strippers to remove plastic wire coating. Connect both ends from the appliance and the green and yellow wire that was shipped. Use a wire nut (also shipped in the box) to connect the wires. You will have 2 black wires left on the new condenser fan motor that need to be connected to the appliance. You should have an orange colored wire and another wire that is black with a white stripe. Connect one wire from the new fan motor to the orange wire and use a wire nut to attach both wires together. Use the other black wire from the new fan motor to the black/white striped wire from the appliance. Use the wire nut to attach both those wires. Place the new condenser fan motor back in the appliance using the screws that come with the motor. Attach the green and white wire with the connector on the end to one of the 3 screws that hold the motor in place and secure the screws. Use the electical tape to hold the wires all together and away from the fan motor. Plug the appliance into the outlet. You can see the condenser fan motor working properly. Note that when connecting the 2 black wires from the new condenser fan motor to the orange and the black/white wire from the appliance, for my appliance, it did not matter which wires were connected as the fan motor was a clockwise motor. Place the cardboard appliance backing, back on to the appliance and push the refridgerator back in place. Allow about 5-6 hours to get the freezer to between 0-5 degrees. The refidgerator should be between 34-38 degrees and will take a little longer to get to that projected temp.
Was this helpful?