GDS20KBSDBB General Electric Refrigerator - Instructions

All Instructions for the GDS20KBSDBB
46 - 60 of 304

Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!

Search filter:
Clear Filter
Your search term must have 3 or more characters.
broken dairy door cover
5 of 7 people found this instruction helpful.
  • Tom from Fresno, CA
  • Really Easy
  • Less than 15 mins
removed old one and installed new one. 30 seconds.
Was this helpful?
Thank you for voting!
Icemaker solenoid housing cracked
5 of 7 people found this instruction helpful.
  • Mark from Bayside, NY
  • Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
The original piece was already removed. installation required a little custom fitting as the mounting was slightly different and the copper tubing from the water line needed to be bent to fit. The push in plastic connection (output to the icemaker itself ) was simple ( I was a little leary of it not leaking.)
I plugged in the solen oid connection first
I attached both water lines and checked for fit. Made the adjustments and then screwed the bracket back on to the refrigerator. I could only install one screw but it holds it fine. I did have to trim the hard press board(cardboard) a little to fit the new valve. I believe the board is to protect against dust build up on the mechanical equipment (motor, condenser,etc)
Was this helpful?
Thank you for voting!
Wasn't Getting Any Water To The Icemaker
5 of 7 people found this instruction helpful.
  • Mark from Ft. Lauderdale, FL
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
It could not have been easier. The new part matched the old part exactly. I turned the water off going to the refrigerator, unscrewed one screw from the old part, pulled the electric plug loose, disconnect the copper water line from old part, cut off the black plastic tube next to the water valve going to the icemaker, and the new wat er valve was ready to install. It's that simple. I then took the new water valve, connected the copper water line to it, pushed the black plastic water line into its hole, connected the electric plug, and screwed the new part onto the refrigerater. In a matter of minutes I had water running to my icemaker again. I can't imagine the money I saved by doing this simple project myself. This took less than 10 minutes.
Was this helpful?
Thank you for voting!
The Ground wires wasn't in same location on board
4 of 4 people found this instruction helpful.
  • Johnnie from KANSAS CITY, MO
  • Easy
  • 30 - 60 mins
i had to improvise And relocate ground wire to get a proper ground .. That's all , the video was a GREAT HELP...
Was this helpful?
Thank you for voting!
The lights were on inside however the the water/ice dispenser did not work and the fridge and freezer side was not cooling
5 of 7 people found this instruction helpful.
  • Rickey from DUMAS, AR
  • Really Easy
  • 30 - 60 mins
  • Socket set
Simply take off the back panel. Remove the old run capacitor which is attached to the compressor by a white part. It pulls right off. You will have to unplug two wires. I took a pic to ensure I plugged the wires back up the correct way. Then I attached the new capacitor to the white part and put on the sleeve that was included, plugge d it back into the compressor and zip tied the excess part of the sleeve. Once done plug fridge back up (always unplug electric devices when doing maintenance) to check before replacing back panel. It may take a few minutes before it kicks on.
Was this helpful?
Thank you for voting!
Ice maker water valve failed open.
5 of 7 people found this instruction helpful.
  • O. V. from Virginia Beach, VA
  • Easy
  • 1- 2 hours
  • Nutdriver, Screw drivers, Socket set, Wrench set
The replacement single outlet water valve was not an exact replacement and required a slightly different mounting position. The original plastic hose to the ice maker attached to the valve with a plastic nut. The new connection requires only pushing the hose into a hole in the valve. Easy and simple. However, the new mounting angle prompt ly broke the brittle old plastic hose. I was able to pick the broken pieces of hose out of the valve with a fine point pick saving the new valve. If I hadn't been able to pick the broken pieces out of the new valve I would have had to order another one. Off to the big box store to buy new 1/4 inch plastic hose and a coupler. Repair completed and no leaks. If the hose hadn't broken, the I would have been done in 15 minutes. I suggest you plan to replace the entire plastic hose when you replace the valve.
Was this helpful?
Thank you for voting!
Electric surge from lightening strike close to house
4 of 5 people found this instruction helpful.
  • Richard from Clarksville, GA
  • Easy
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers
Obvious that main electronic board was fried. Refrigerator and freezer both not working although fan was running. Replaced main board and run capacitor. Compressor not running. Pulled starter relay and checked compressor connections for continuity. Checked ok. Ordered starter relay and installed with new capacitor. Compressor started and has been running quiet and cold ever since. Thanks to videos on partsselect website for offering the confidence to try the fix myself. Total spent on parts and shipping,$350. I had electric provider install surge protection behind meter for a cost of $5.70 a month. Hope it works as advertised.
Was this helpful?
Thank you for voting!
Freezer/Fridge not cold & compresser would not turn on.
4 of 5 people found this instruction helpful.
  • Linda from Tiverton, RI
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Pliers, Screw drivers
For troubleshooting, I took off rear panel inside of the freezer compartment & determined that icing of the coils was not the problem & it did not apprear to be a defroster malfunction. All components appeared to be working properly except the compressor would not turn on and only room temperature air was being circulated by the fan. Aft er narrowing the probable causes down to a faulty Main control board by reading as many similar posts as possible,I ordered the new control board. When it arrived the following morning via UPS(less than 24 hours!), I unplugged the wiring connections attached to the old board, (which was somewhat different in appearance), and then gently popped the circuit board off of the plastic retainer studs by pushing in the little retaining clip part of the studs in with a small screwdriver so the board could be released easier as I pulled outward. I popped the new board on the studs by gently & evenly pushing with a larger hut driver over the studs until it was locked in, being careful not to damage or over stress/bend the board. I placed the wiring connecters onto the pins on the board.....every connecter had a different amount of pins so improper connection was not possible. I placed the ground wire connection of the new board between the metal cover plate @ an adjacent screw location to ensure grounding to the back of the fridge sheet metal. I plugged in the refrigerator and was quite relieved when I heard the compressor start up after a second or two! Within moments the temp began to fall until it reached the proper temp in both compartments. Success!
Was this helpful?
Thank you for voting!
Ice cream melting, lettuce freezing
4 of 5 people found this instruction helpful.
  • Tim from Mountain View, AR
  • Easy
  • 15 - 30 mins
  • Nutdriver, Pliers
Removed the back cover over the control board, and made sure that the board was the same. It didn't look exactly the same, but figured that it was the same, just updated. Took out the board, moved the wires to the new board and reinstalled. Plugged it in and it came on, so I reinstalled the cover. Seems to be working to this day.
Was this helpful?
Thank you for voting!
cracked valve
6 of 11 people found this instruction helpful.
  • Don from Crete, IL
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
Super simple. Extremely fast delivery of part. Simply disconnect the 2 fast-on connectors to valve, disconnect intake and out lines. connect intake and out tubes to new unit, mount via screws to fridge, reconnect the 2 fast-on power connectors and your back in business. Could not be an easier repair.
Was this helpful?
Thank you for voting!
Ice maker stopped working.
5 of 8 people found this instruction helpful.
  • Alice from Vancouver, WA
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers, Socket set
I first replaced the ice maker and when that didn't work, I found out through this forum that another possibility is the water outlet valve.

When I got the replacement, it took some time to install because the bracket wasn't the same as the original. There are enough places on the bracket to mount the unit, but it may requir e using some force to bend the bracket so that it will flush with the wall.

After installation, it took about 2 days to fill up the ice bin. It cycles out ice crescents every 2-3 hours.

Thanks partselect for having this forum and saving me some money by having others share their experiences.
Was this helpful?
Thank you for voting!
No ice or water at the despenser. Compressor would turn off when the dispenser lever was pushed. There was also a loud buzzer sound for a couple of weeks prior to the board failing.
3 of 3 people found this instruction helpful.
  • Pat from Pensacola, FL
  • Easy
  • Less than 15 mins
  • Nutdriver
Pulled out the fridge and unplugged electric cord. Took off the back lower right side panel. Unplugged all the connectors and removed the motherboard. Replaced the motherboard and reconnected connectors. Replaced the panel and plugged it in. Works great!
Was this helpful?
Thank you for voting!
clicking nose from mother board
3 of 3 people found this instruction helpful.
  • LEE from WILMINGTON, DE
  • Easy
  • Less than 15 mins
  • Pliers
pulled the board away from the 4 plastic pins, unplugged the wires and plugged them directly into the new noard, pushed board back onto the four plastic pins.......job completed in under 5 minutes. Fridge working fine now for over a week......no problems.
Was this helpful?
Thank you for voting!
clickking sounds
3 of 3 people found this instruction helpful.
  • Aurelio from MAYS LANDING, NJ
  • Very Easy
  • Less than 15 mins
Unplugged unit.. Removed control board cover.. Removed all plugs from control board then removed board its self.. Replaced in reverse order.. Unit is working as new..
Was this helpful?
Thank you for voting!
broken outlet valve
5 of 9 people found this instruction helpful.
  • KEITH from WINDER, GA
  • Really Easy
  • Less than 15 mins
  • Pliers, Screw drivers
All the repair people was on the money . I read them all .1--- NO paper work with new valve (.no instructions) ..2--- bracket is not the same .. I reversed my braket and it worked fine .you do not have to bend bracket.3--- It will take a day or so to start making ice..4--- the plastic nut is no longer needed on the new type outlet valve . ...5--- the new outlet valve looks a little different from the old valve. WORKS GREAT ..
Was this helpful?
Thank you for voting!
All Instructions for the GDS20KBSDBB
46 - 60 of 304