Models > F12A1FDP > Instructions

F12A1FDP (ABWEEUS) LG Washer - Instructions

All Instructions for the F12A1FDP
46 - 60 of 84
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Gave LE code
Former LG repair looked under washer while it was engaging & noticed motor was not spinning. LG took forever I ordered the part from you guys. It looked different from original. Figured out to take extra port for front loader. I have top loader. Installed washer works great!!
Parts Used:
STATOR ASSEMBLY
  • Michael from SAINT LOUIS, MO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Socket set
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The hot water inlet valve was leaking at the seal between the valve and cellinoid.
Some screws, some clamps. Easy and straight forward. unplug machine, turn off water, disconnect water hose, unscrew top of machine (2 philips head screws), disconnect clamp from valve (use a towel for remaining water), disconnect wire, unscrew from place holder, remove entire valve, work backwards from there.
Parts Used:
Water Inlet Valve - Hot
  • john from pearl river, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
slow water leak
Pull the washer away from the wall to get behind it. Unplug the electrical power cord from the wall. I removed the top cover by unscrewing the 2 screws on the back of the washer. Slide the cover back about 1-2 inches towards the back of the washer and then lift the cover up and remove. It might be a little tight to slide back, you may need to wiggle the cover side to side or give it a good smack. The water inlet valve is directly at the top inside of the washer. I saw a slow leak dripping from the hot water inlet valve onto the back side of the drum. Turn off the water supply valve at the wall and then unscrew the supply water hose from the water inlet valve at the back of the washer. Disconnect the electrical connector and water hose from the inlet valve inside the washer. From the outside of the washer on the back, remove the screws holding the water valve and lift out the valve. Install in reverse order.
Parts Used:
Water Inlet Valve - Hot
  • mark from pleasant prairie, WI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
A leak was created via puncture of metal part of bra that fell out.
Remove old one and replace. Just make sure it is all the way on and secure or you will have a huge mess on your hands.
Parts Used:
Tub-to-Pump Drain Hose
  • Travis from Marietta, GA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Cold water inlet would not shut off
Extremely easy--remove two screws in the back of washer connect elec. connections one at a time connect cold water lines one at a time and replace the two screws ion the back and you are done. Took longer to pull washer out from wall and push back than it did to replace part. Saved me $75.
Parts Used:
Inlet Valve Assembly
  • ronald from Corpus Christi, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Leaking Hot Water Inlet VBalve
Turn off hot water supply and activate a cycle on the washer momentarily, with hot water selected on front panel options to relieve hose pressure. Slide washer out to gain access to rear of unit. Unplug washer from AC source. Using pliers, remove washer supply hose from washer-side of the line (water may drain from hose) Remove single Phillips screw at bottom of each nylon lid holder at rear. Using a plastic putty knife, place between front panel and top lid to loosen lid and slide to rear. Remove lid and store aside. Hot and cold inlet valves sit side-by-side at top rear of the unit. Disconnect connector from valve by pulling gently away from valve plug prongs and place to the side. Using pliers, compress hose clamp and move to lower section of hose. Carefully rotate hose back and forth to remove from assembly. Inlet valve is held to washer body rear with 3 small Phillips screws. Remove first 2 and then while holding inlet valve body, remove final screw to free inlet valve assembly. Replace with new assembly by reversing these steps.Make certain when supply hose is reconnected, it is firmly tightened but DO NOT over tighten. Test washer by running a cycle to ensure there are no leaks.
Parts Used:
Water Inlet Valve - Hot
  • JOEL from BIXBY, OK
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
It was torn and leaking.
Took off the old one and put the other one on. The only difficulty was that my husband has big hands and had a hard time getting to one end.
Parts Used:
Tub-to-Pump Drain Hose
  • Denise from Show Low, AZ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Wrench (Adjustable)
Was this instruction helpful to you?
Thank you for voting!
Lock assembly displaying DE code
Unplug washer!!! 1. Remove retaining ring around rubber gasket with flat head screwdriver. Just slightly pry off and it will easily come off. 2. Just peel back rubber gasket on the side that the lock is on. 3. remove 2 screws from the front off the lock assembly. 4. gently reach in and lift the little plastic clip holding the wiring harness and lift straight off. If the clip is lifted it might be a little tight just use even steady pressure to pull off. 5. Reverse these instructions to replace. Note: replacing the retaining ring on the rubber is a pain. The spring has to be in the bottom. Using a couple of flathead screwdrivers you can wrangle it back in place after awhile. There is a tool that looks like a large reverse pliers that may make it easier. Anyway thats it, pretty easy. There is a youtube video that shows all of this.
Parts Used:
Door Lock Assembly
  • Robert from Saugus, MA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Water was leaking from under the washer.
The bellows hose on the bottom of the tube had worn through where it flexed. This was an easy job except for the long reach you had to make under the washer to reach the hose clamps that held the part in place. These were spring loaded clamps which were easy to remove with pliers. I replaced them with ones that could be tightened with a socket wrench since it was hard to replace the sprung clamps.
Parts Used:
Tub-to-Pump Drain Hose
  • Richard from Blue Bell, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Water leaks at both valves
Disconnect electric and remove top cover and remove connectors and hoses then the valves
Parts Used:
Inlet Valve Assembly Water Inlet Valve - Hot
  • Tommy from San Marcos, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
Was this instruction helpful to you?
Thank you for voting!
small water leak
The difficult part was finding the leak since it was very small and the washer was completely wet around the frame at the bottom. After completely drying everything off and waiting an hour-nothing.I had assumed the leak was in the bottom area around the hoses when actually the leak was the cold water valve[top rear] seeping,then dripping on the drum and dripping onto the frame 8 inches away.I ordered the valve about 10:30am online, the next day at 1pm it arrived. Very easy to install in 15 minutes.
Parts Used:
Inlet Valve Assembly
  • James from Antioch, TN
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Leaking water valve
Hot water valve was leaking when washer was not in use and flooded floor. Advised owner to replace hit and cold water valve same time since only hot valve was bad. Hot water was easy but cold was difficult because it has the bleach and softener valve attached in one unto with three hoses and three wire connections. The opening at back of machine was small and you must have small hands to replace them. If not, then you have to remove top cover to get to it which is extensive.
Parts Used:
Inlet Valve Assembly Water Inlet Valve - Hot
  • Desta from Brooklyn, NY
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Will not start after dorr is closed. Shows Code dE. Door locks properly, two clicking is heard before code shows up.
1. Remove spring-loaded clamp assembly. 2. Partially pull out the large rubber gasket near the lock switch assembly to gain access to the lock switch assembly. 3. Unscrew two screws holding the lock switch assembly. Carefully separate the connector from the lock screw assembly and replace it with the new part. Reinstall in reverse sequence. Ensure that the electrical connector is fully seated unto the lock switch assembly and the connector latch is fully set against the lock switch body. Also make sure that the large rubber seal is fully seated around the door opening to prevent water leak. Restarted the washer and everything worked as before.
Parts Used:
Door Lock Assembly
  • Juan from Anaheim, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Inlet cold water valve leaking
Ordered a new water valve, easy installation, removed top cover of washer. Two screws and three hose clamps, done in 20 minutes.
Parts Used:
Inlet Valve Assembly
  • Howard from Aubrey, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
leaking from solenoid
removed 2 screws on back. removed top. disconected wires and hoses removes 2 screws holding assy in place and removed assy. put in new assy and installed hoses and plugs in same location removed from. reinstalled top and hose and ran washer.. new valve unite works but has a high pitched whine when valves turn on. :(
Parts Used:
Inlet Valve Assembly
  • Creed from Surprise, AZ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the F12A1FDP
46 - 60 of 84