EW23CS70IS7 Electrolux Refrigerator - Instructions

All Instructions for the EW23CS70IS7
121 - 135 of 344

Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!

Search filter:
Clear Filter
Your search term must have 3 or more characters.
Fridge started making a loud racket. Condenser Fan Blade then disintegrated to dust and pieces. The plastic had degraded significantly.
4 of 7 people found this instruction helpful.
  • Jack from WALLING, TN
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Socket set
The repair itself total time was quick and easy. Since the original fan blade blew apart, it was only a matter of putting the new one on in it's place. This can be done by feeding the blade between the cowling and Condenser coil and applying pressure to get it on the shaft.

If your fan is still on the shaft, simply push it off and extract it the same way. Then place the new one on the shaft.

In my case, since the part would take a couple days to get, and I had food both in the fridge and the freezer, I removed and unplugged the Condenser Fan Motor and the cowling frame and temporarily spliced a small fan I had into the line for the condenser motor. This kept the fridge working long enough to get the replacement part.

Side note. Direction of airflow is towards the Compressor, and draws air across the Condenser coils.

Hope this helps someone. :)
Was this helpful?
Thank you for voting!
Icemaker was producing hollow ice due to water was free flowing out the water dispenser during fill time for icemaker.
3 of 4 people found this instruction helpful.
  • Melissa from Olden, TX
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
Removed old water valve w/ screwdriver, cut threads off old hose (as they just plug straight into new valve) & pushed hoses into new water valve. Solved both problems!!!!
Was this helpful?
Thank you for voting!
Fridge leaked water all over my kitchen
3 of 5 people found this instruction helpful.
  • Craig from Eastlake, OH
  • Really Easy
  • 15 - 30 mins
  • Pliers
I watched the video and followed every step as outlined. It worked perfect, until I reconnected the supply line to my triple water valve. I used the old compression fitting and the compression nut. I should have cut the line and installed a new fitting and nut. The water on the floor the next morning reminded me of that. So back out I wen t and replaced the compression fitting and it has been as good as new. The ice maker took a few cycles to work again, I think it needed to fill the line with water first. But I have a huge sense of pride every time I hear water dispenced or ice dump in the freezer. Thanks for the help and encouragement!
Was this helpful?
Thank you for voting!
Ice Director Door Broken In Half
2 of 2 people found this instruction helpful.
  • Cloid from HOOVER, AL
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Pliers, Screw drivers
I was able to replace the housing by only removing the front cover, the e-ring and washer and the 3 hex-head screws. I was able to work the old housing around to get the actuator arm off and then get it properly inserted into the new housing. Attach the new housing, IMPORTANT: make sure you get the fixed-blades and spacer assembly in the slot of the housing that holds them in place, replace the e-ring and washer, check that the actuator arm operates the door properly and replace the front cover. The videos can be helpful but these shortcuts will save some time.
Was this helpful?
Thank you for voting!
LEAKED WATER AFTER USING WATER DISPENSER
2 of 2 people found this instruction helpful.
  • Mark from LANCASTER, KY
  • Easy
  • 15 - 30 mins
  • Nutdriver, Wrench (Adjustable)
DID IT JUST LIKE THE VIDEO SHOWED. UNHOOKED ELECTRICS, CUT TUBING, HOOKED UP ELECTRICS THEN TUBES TO NEW PART. PIECE OF CAKE.
Was this helpful?
Thank you for voting!
Part broke though normal use
7 of 17 people found this instruction helpful.
  • Hugh from Berthoud, CO
  • Easy
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers
Called "local" repair warehouse and ordered part. They shipped the wrong part. Went on-line to Part Select and got the right part.
Was this helpful?
Thank you for voting!
Refrigerator was icing up
2 of 2 people found this instruction helpful.
  • Verdell from NEW ORLEANS, LA
  • Easy
  • 30 - 60 mins
I changed the defrost thermostat and the heater.
Was this helpful?
Thank you for voting!
Ice Crusher Houseing cracked broke into pieces
2 of 2 people found this instruction helpful.
  • Curtis from ROCK HILL, SC
  • Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
Remove ice drawer ,Removed front of drawer 4 screws ,Removed broken crusher 3 screws Ordered new parts reassembled replaced fix blade spacer that was broken and blade cover housing reattached front of drawer !
Was this helpful?
Thank you for voting!
Filter was dirty
11 of 29 people found this instruction helpful.
  • Angel from Tampa, FL
  • Really Easy
  • Less than 15 mins
  • Screw drivers
Just push the button on the top right hand and pull the filter out; then proceed to instal the new one pushing it in place. It's really an easy operation!!
Was this helpful?
Thank you for voting!
One blade broke from condenser fan
12 of 32 people found this instruction helpful.
  • Chris from Lockport, NY
  • Really Easy
  • Less than 15 mins
The part i recieved, from parts select was a larger in circumfrence (<1/4) than the original. However i was not aware of this until after i treid to repair it.

I removed the broken fan from the condenser. This was very sipmle.

When i pluged the refridgerator back in to the outlet the fan tried to start up but soon be gan to make aloud noise, due to there not being enough clerance.
Was this helpful?
Thank you for voting!
Crisper bin track support
2 of 2 people found this instruction helpful.
  • Ruth from Lake Forest, CA
  • Really Easy
  • Less than 15 mins
  • Pliers, Screw drivers
The part arrived in about 2 days! The right side support that is attached to the inside wall of the refridgerator, that holds the crisper guide, broke apart and would not support the crisper. We took everything off of that shelf and took out the crisper and the glass that is on the shelf. We then carefully pried the support from the in terior wall (it was a slow tedious move to be sure we did not damage the wall of the fridge). We made sure all of the pieces were out and snapped the new one into place. For some reason the old one did not want to come out. It broke into many pieces and we carefully pulled all of the little pieces out of the notches
Was this helpful?
Thank you for voting!
No water to ice maker
2 of 2 people found this instruction helpful.
  • John A from BRUNSWICK, GA
  • Very Easy
  • Less than 15 mins
  • Screw drivers, Wrench (Adjustable)
Original unit had screw on lugs. After removing old unit, I unscrewed the lugs, cut the lines to remove the nuts and inserted them into the new unit. Everything was color coded so connection was simple. Reinstalled unit, cycled the ice maker several times only to discover the fill tube at in the freezer had frozen ice blocking the tray f rom getting water. Used a hair dryer to thaw out the tube, water flowed instantly. Very easy repair.
Was this helpful?
Thank you for voting!
Broken hinge bearing, refrigerator door, top bearing
2 of 2 people found this instruction helpful.
  • Chris from CHAMPLIN, MN
  • Very Easy
  • Less than 15 mins
  • Screw drivers, Socket set
1. Using Philips head screwdriver, remove plastic hinge cover on top of refrigerator door.
2. Remove bolts using socket wrench.
3. Lift door from bottom hinge.
4. With Philips head screwdriver remove screw holding bearing in place on bottom of door.
5. Remove old bearing.
6. Install new bearing.
7. Replac e fridge door using reverse steps.
8. Enjoy your handi-work.
Was this helpful?
Thank you for voting!
Freezer was cooling, but refrigerator was not cooling all the time. Evaporator fan was running, so decided to try new thermostat.
2 of 2 people found this instruction helpful.
  • Patrick from ROGERS, AR
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
Followed install instructions on utube. Once freezer was empty, back panel was easily removed, and defrost thermostat was in plain sight, and easy to replace. Hope that solved my problem. Refrigerator has been plugged in for four days now, and is cooling properly so far.
Was this helpful?
Thank you for voting!
Ice maker knot making ice
2 of 2 people found this instruction helpful.
  • John from KANE, PA
  • Very Easy
  • Less than 15 mins
  • Nutdriver
Very simple less then five minutes.
Was this helpful?
Thank you for voting!
All Instructions for the EW23CS70IS7