I had a water leak (undiscovered) from under my refrig
22 of 24 people found this instruction helpful.
  • Daniel from Anderson, SC
  • Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
After de-energized unit (by removing electical plug from outlet),I removed the rear panel at bottom of unit. I then removed the mounting screw to the water valve. I then disconnected the wiring assembly from the old unit. I then removed the water supply lines going to the icemaker and water filter. I then placed the water supply into the replacement water valve. plugged in wiring assembly to new unit and rehung water valve inside refrig. Turned water valve on at water supply to check for leaks, finding none I then replaced back panel on refridge and plugged in electrical cord and returned refrige to normal place in kitchen.
Was this helpful?
Thank you for voting!
Freezer and fresh food section getting warm due to inside coils frosting over.
24 of 30 people found this instruction helpful.
  • John from Windham, NH
  • A Bit Difficult
  • 1- 2 hours
  • Pliers, Screw drivers, Socket set
No self defrost. Measured heater coil with ohm meter which was OK (not open). Ordered 2 temp sensors (there are 2 in freezer, 2 in fresh food sections). The original and the new all meaured ~150 ohms. Replaced one by one. This did not fix problem. Ordered defrost thermostat. Original measured ~150 ohms - new one was ~100 ohms. Unpluged r efridgerator. Removed coil panel (4 nut screws) in freezer and light cover (1 small phillips screw). Locate defrost thermostat clipped to top of coils (orange / pink wires). Cut wires and unclipped thermostat. Stripped insulation off of wires and reconnect using wire nuts. Clipped thermostat back to coils. Ran refridgerator without panel on coils to see if coils frosted up again and listend for fans/compressor to stop ( took hours). Opened freezer and viewed glow of defrost heater. Problem resolved.
Was this helpful?
Thank you for voting!
Noticed pieces of broken plastic in my ice cubes.
22 of 25 people found this instruction helpful.
  • G from Spring Hill, FL
  • Easy
  • 15 - 30 mins
  • Screw drivers
Of course, the first thing I did was remove the ice cube container from the freezer, and dump the ice cubes. (Conservation note: If you're in a place with water conservation rules, dump the cubes in a big pot and save them. If they melt, use the water for your house plants.) Following the advice from another DIYer, I let the container war m up before doing anything further.
Turned the container (I'll call it the "tray" from now on) over, removed the two screws holding the front cover with the Phillips screwdriver, gently pulled the cover out to disengage it from the rest of the machine.
Getting the next part out was tricky because it didn't want to release just by pushing in on the tabs on either side of the front assembly. That's where the two table knives came in, courtesy another reviewer. Be careful here not to jam or twist too energetically because the plastic housing is still quite breakable.
Just to be safe, I unscrewed one more screw that held the little bracket holding the rod with the spring on it and disengaged it. Then I discovered that I had to unclip the part that holds the auger in the front part of the assembly and slide the auger out of the way so I could pull the broken part out.
Having done all that, putting the new part in and reassembling the whole thing was pretty easy.
Slide the new part in, carefully rotate the auger back into its place, slide that assembly back into place, replace the clip holding the end of the auger, be sure the long rod engages the ice crusher gizmo, replace the screw that holds the rod in place, hook the front of the drawer back into the proper slots, rotate the cover back into position and replace and tighten the two screws.
You're done! The ice cubes you took out will probably still be frozen, so you can dump them back into the tray and slide the tray back into the freezer.
If you're cleverer than I am, maybe you won't need to do all the little things I did, but even so the whole exercise took less than 15 minutes--the ice cubes didn't even melt!
Was this helpful?
Thank you for voting!
Very high pitch whine. Not real loud but really annoying.
22 of 25 people found this instruction helpful.
  • ronald from kissimmee, FL
  • A Bit Difficult
  • 1- 2 hours
  • Nutdriver, Screw drivers
First I hired a repairman and he said that it was in the unit and would not be worth the expense to fix.

I started to research on the net and this was one possible source. ( evaporator fan). I had to take it apart to verify it. Then put it back together to use until the part came.

The next time went much faster as I did not have to take near as many screws out to access the fan motor. Very Happy to have it working fine again as a new relacement would cost $1200. Thanks much. Ron
Was this helpful?
Thank you for voting!
Main circuit board wouldn't allow the compressor to come on
22 of 26 people found this instruction helpful.
  • Leonard from Keller, TX
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
Removed old circuit board and replaced with new
Was this helpful?
Thank you for voting!
part of auger broke
22 of 28 people found this instruction helpful.
  • Gary from Spring Hill, FL
  • Really Easy
  • Less than 15 mins
We ordered the basket with auger and all I had to do was take the old one out and slide the new one in. EASY !
Was this helpful?
Thank you for voting!
Ice dispenser door sticking open.
28 of 46 people found this instruction helpful.
  • Wallace from Oxford, ME
  • Easy
  • 15 - 30 mins
  • Screw drivers
Unplugged power cord. Used a small screw driver to release the bottom of the control panel. Pulled it out and unplugged wires, then set it aside. Removed 4 screws from the housing shield and pulled it out. Now the solenoid assembly and related parts are accessable. I removed the solenoid assembly by loosening the top screw and removing th e 2 bottom screws. This was the main problem, but I also replaced related parts that were worn or corroded. I also cleaned and disinfected everything in there while I had it apart because it was pretty nasty! Now it works like new.
Was this helpful?
Thank you for voting!
Water dispenser won't always dispense water
27 of 45 people found this instruction helpful.
  • Curtis from Corona, CA
  • Easy
  • 15 - 30 mins
  • Pliers, Screw drivers
I followed the instructions found on this website. I removed the control panel by inserting a small Phillips screwdriver in the three holes at its bottom. I used the same screwdriver to pull the dispenser assembly down but could have used a larger one. The microswitch could be seen in the assembly at that point and was easily removed b y opening the "fingers" that held it in place. I attempted to pull one of the terminals off without using a pair of needle-nosed pliers and ripped the wires right out of the terminal(I was able to find a replacement at Radio Shack). Low and behold after reinstalling the new part, it did not take care of the problem.

My problem is the water dispenser does work intermittently. When we place the glass in position and hit the lever, the lights in the control panel go off and no water is dispensed. My next guess may be the water valve or the control panel. The icemaker makes ice but I have had problems with it dispensing for nearly a year now.
Was this helpful?
Thank you for voting!
Replace ice maker
21 of 28 people found this instruction helpful.
  • Gary from Glendale, AZ
  • Easy
  • 15 - 30 mins
  • Screw drivers
New ice maker only used 2 screws and the old one had 3. This was no problem. The old ice maker had already been removed. Just loosen the 3 screws and unplug the cord to ice maker. Only problem with ice maker was with the cord, which I had to use the supplied adapter. It was too long and in the way when reinstalling the ice bin. The ice b in had a small notch area on the bottom left. I used a plastic tie to bundle the cord into the notch. Carefully placed ice bin and no problem. The first part I received was damaged and was replaced 2 days later by a brand new part. Customer service charged for the replacement part but said they would credit my charge card within 2 to 3 weeks for the damaged part. Its been a week and if they follow thru like the said I woild give Part Select 5 Stars for service and Parts.
Was this helpful?
Thank you for voting!
The refrigirator light would not come on.
26 of 44 people found this instruction helpful.
  • Jania from Novato, CA
  • Really Easy
  • Less than 15 mins
  • Screw drivers
Poped out with screwdriver the old swithch and unplugged the two wires. Plugged in the wires to the new swithch and pushed it back in the hole where the old switch was before.
Was this helpful?
Thank you for voting!
Dairy Door Cover had cracked
21 of 29 people found this instruction helpful.
  • Stephanie from Tampa, FL
  • Really Easy
  • Less than 15 mins
Repair took about 5 seconds. No directions necessary. Super easy.
Was this helpful?
Thank you for voting!
no problem
18 of 21 people found this instruction helpful.
  • William from West Union, SC
  • Really Easy
  • Less than 15 mins
I had lost the provided bypass filter plug. I decided to replace it with your part.
Was this helpful?
Thank you for voting!
Cracked Housing Mount - water leak
19 of 25 people found this instruction helpful.
  • Richard from Chandler, AZ
  • Really Easy
  • 15 - 30 mins
  • Screw drivers, Socket set
Turned off the water. Removed the maintenance cover plate on the back of the refrigerator and disconnected the tubing. Removed the tubing cover plate on back of refrigerator. Removed two screws from filter hosing mount on the inside of the refrigerator and pulled the old tubing out. Simply inserted the new tubing and mounted the housing a nd reconnected the tubing using plumber’s pipe compound. Then re-installed the cover plates on the back of the refrigerator, installed the filter and turned on the water. It was a very easy install.
Was this helpful?
Thank you for voting!
Stripper on the icemaker broke into pieces.
18 of 23 people found this instruction helpful.
  • Tracy from Yuba City, CA
  • Really Easy
  • Less than 15 mins
  • Nutdriver
Remove the two nuts holding the top of the unit to the side of the freezer using a 1/4 in nutdriver. Pull the unit out and unplug it from the back of the freezer. Remove all pieces of the broken stripper. The replacement part fits onto a peg on the back of the icemaker and into a slot. Bend into place and slide into position.
Was this helpful?
Thank you for voting!
A piece of the crusher cover broke off into the ice bin
18 of 23 people found this instruction helpful.
  • David from Woodland Hills, CA
  • Really Easy
  • Less than 15 mins
  • Screw drivers
I removed the ice bin, removed the metal rod off the bottom, unscrewed all screws holding things together and then carefully pried the crusher assembly out of the ice bin. I made the mistake of doing it when the bin was still frozen and ended up cracking it where the "clips" from the crusher are inserted. It was much easier after the bi n warmed up.

Replaced and put everything back together.