Water line retainer missing in one port of new valve
carefully removed retainer from old valve
Parts Used:
Refrigerator Water Inlet Valve
  • William from DUCK RIVER, TN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water valve was leaking
The u tube instructions were exactly what is needed. I had to cut off the old plastic pipes. My pipe had threaded connectors. Pex push on connection is super easy. You don't really need a block of wood to cut it if you have a sharp utility blade. If if you are sure this is the problem this is a really easy fix. Steps 1 turn off water at wall unplug electric also 2. Disc line at valve on refrigerator 3. Remove 2 screws holding valve 4. Pull valve out and remove plastic hoses and electric connections pay attention to color of pipe and electric connection. Mine were color coded. Had to cut off thread connectors. Reattach in reverse order or do one at a time. Check for leaks.
Parts Used:
Refrigerator Water Inlet Valve
  • Randy from GUYMON, OK
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Wrench (Adjustable)
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Valve body separated : major leak.
Write down where tubing goes, wiring is color coded.
Parts Used:
Refrigerator Water Inlet Valve
  • Robert from NASHVILLE, TN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
I let value was leaking its self
Undo a few bolts unplug power and unhook water lines then recut all lines and push in to new value
Parts Used:
Refrigerator Water Inlet Valve
  • Mitchell from FOXWORTH, MS
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Wrench (Adjustable)
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
NO PROBLEM JUST DECIDED IT WAS TIME TO CHANGE FILTER
VERY EASY SLIDE OLD ONE OUT AND PUT NEW ONE IT
Parts Used:
Air Filter
  • Gregory from POTTSTOWN, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
During cross country move, water valve froze and broke.
Straight forward repair. Remove the four screws holding cardboard back. Remove the 2 screws holding the valve. Unscrew the water lines and unplug the electrical connections. I would caution that it would be wise to either take a couple photos or write down the order of connection. Even though it is somewhat color coded and the water lines are different sizes, a photo removes any confusion. My old valve had threaded connections using brass nuts and ferrules. The new valve has push in connections so you need to cut the ferrules off.. When cutting off the tubing, be sure to cut square. An angled or "squished" cut will leak when pushed into the fitting. Attach the valve to the refrigerator with 2 screws and replace the cardboard back and you're finished. While you have the back off is a good time to clean the coils. I left my fridge out and back off for a couple of ice making cycles so I could check for leaks (how I know the tubing needs to be cut very square). All in all, a very easy fix.
Parts Used:
Refrigerator Water Inlet Valve
  • Eldon from HALLAM, NE
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Wrench (Adjustable)
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water was leaking from the old valve
Watched the video on your website and you can’t go wrong.
Thanks for being there
Mike
Parts Used:
Refrigerator Water Inlet Valve
  • Michael from Double springs, AL
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Pliers, Wrench (Adjustable)
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator wasn't "winterized" ..This is a summer home, the cold winter cracked the water valve
I put the new unit up to the old one to see exactly how it goes, took the 2 screws holding the unt off...Took the 3 water lines off with adjustable wrench, put back exactly the same way and it worked with no leaks
Parts Used:
Refrigerator Water Inlet Valve
  • Jimmy from west sayville, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Wrench (Adjustable)
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker not making ice
The part was easy to install and solved the problem! We had ice within hours. Thanks PartSelect!
Parts Used:
Refrigerator Water Inlet Valve
  • ruth from vancouver, WA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer Cold, but Refrigerator not Cold
We replaced the damper, but it didn't fix the problem. We then purchased and replaced the thermistor. (We had previously replaced the defrost thermostat). The refrigerator side is now cooling better, but not enough. The damper doesn't seem to be opening. So we have now unplugged the damper and left the opening between the refrigerator propped open and the refrigerator side is now cool enough. (We had previously tried keeping the damper open before we replaced the thermistor and the refrigerator didn't cool off. So the thermistor did fix something, but the damper doesn't seem to have been the problem).
Parts Used:
DAMPER W/ SEALS, SXS
  • Debbie from Mount Juliet, TN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
left out in the cold an froze
remove the old one and replace with the new one and yes it was that easy. All of the lines and wiring connectors were color coded
Parts Used:
Refrigerator Water Inlet Valve
  • Alvin from Barbourville, KY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Leaking Water Vlave
Just follow the instruction that come with the valve. Easy.
Parts Used:
Refrigerator Water Inlet Valve
  • Joe from Pittsburg, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Socket set, Wrench set
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water began to leak from valve
We followed the online instructions and tah-dah it was working...
Parts Used:
Refrigerator Water Inlet Valve
  • Rebecca from Sapulpa, OK
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Wrench (Adjustable)
2 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No problems
I had no problems. Screws arrived sooner than expected. It was a very simple installation. Very pleased with both the product and service.
Parts Used:
Screw
  • Nancy from LEHIGH ACRES, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Wrench (Adjustable)
2 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No water to ice maker
Repair was easy. Unplug refrigerator, turn off water to ice maker, remove back panel, disconnect water inlet valve, disconnect water supplies and electrical connections. Cut ends off tubing to modify to new part connections, connect tubing, connect electrical supplies, reinstall back panel, plug refrigerator in, turn water supply back on. We made sure that there was no ice build up in the supply tube into the ice maker and made sure that everything worked correctly before putting it all back together. It was an easy repair.
Parts Used:
Refrigerator Water Inlet Valve
  • Joel from SODUS POINT, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Wrench (Adjustable)
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the E23BC68JPSFA