7 of 11 people found this instruction helpful.
  • Robert from Cutler Bay, FL
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers, Wrench (Adjustable)
The hard part was cleaning the dust around the coil and fan area. Its plug and play right after that. Two nuts on the fan housing and a wire harness snaps on and off. Bam! 1,2,3 Up and running. . Like new. . . Thank you ps
Was this helpful?
Thank you for voting!
No water from the dispenser
5 of 5 people found this instruction helpful.
  • Anthony from Carmel, IN
  • Really Easy
  • 15 - 30 mins
  • Screw drivers, Wrench (Adjustable)
I pulled-out & unplugged the refrigerator. Removed the screws to gain access through the lower back panel. The water valve is on the left side as I face the back of the fridge. It has one screw holding it to the frame of the fridge. Once it is free, the main water hose is unscrewed and the two out-let lines were pulled-out. If your v alve was not ruined prior to this, it is ruined now, as the lines will not re-seat. Then everything is done in reverse order. I did cut 1/2 inch off of the two lines so that they reseat into the new valve. Just push into the valve and they are good.
Was this helpful?
Thank you for voting!
Unit had stopped making ice
5 of 5 people found this instruction helpful.
  • Ron from ORANGE, CA
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
Ordered the icemaker replacement. unplugged the unit, followed the simple instructions and got it done in less than 30 minutes. It did take a LONG time to start making ice. But it's working now.
Was this helpful?
Thank you for voting!
Ice maker inlet tube was freezing up, and eventually the icemaker overfilled and completely froze up
5 of 5 people found this instruction helpful.
  • Jake from Brainerd, MN
  • Easy
  • 30 - 60 mins
  • Pliers, Screw drivers, Wrench (Adjustable)
After lots of research online, i narrowed my problem down to be the double outlet water valve, behind the fridge. My biggest problem was getting the refridgerator out of its spot, but after that it was pretty simple to change. I took the cover off the bottom, in the back of the fridge, then i removed the inlet waterline (after i turned off the water supply to the fridge). After that i removed the screw that holds the valve to the framework. Now i pulled off the two other waterlines from the old valve and moved them, one at a time, over to the new valve, along with the wire harness. The rest of the instalation was reverse order. Simple fix that im glad i didn't pay an expert to do!
Was this helpful?
Thank you for voting!
Freezer coils were iced up,was not cold enough,suspected the heater was the culprit
5 of 5 people found this instruction helpful.
  • robert from WOONSOCKET, RI
  • Easy
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers
I had looked at videos on you tube,it looked simple enough. I mostly do my own repairs so I gave it a shot. the job went well,if you do not fix things around the house don't try to do the repair,find a handyman in your neighborhood to help you out,cheaper than calling a refrigeration man. It is not that hard to do.
Was this helpful?
Thank you for voting!
The grill flew off going down the freeway.
7 of 11 people found this instruction helpful.
  • Mark from Ramona, CA
  • Really Easy
  • 1- 2 hours
I took the part out of the package and placed it in the recessed water dispenser/ice maker cavity. Done!
Was this helpful?
Thank you for voting!
cold water dispenser would not stop running
5 of 6 people found this instruction helpful.
  • Robert from Summer feild, FL
  • Really Easy
  • Less than 15 mins
  • Socket set
Turn off the water.
Unplug the refrigerator
Take the back off of the refrigerator
use socket wrenchs to undo and take off the water valve in the lower left corner of refrigerator.
Pull out and disconnect electrical connections
Pull out the 2 water tubes one for ice and 1 for water-white is water and black is ice.
install the new valve and connect the water and ice back in the new unit
connect the two power cords and reattach unit to the frame Turn water on and check for leaks.
If no leaks put back on refrigerator and plug in.
Wait 30 min to an hour for water to begin to flow back into the unit.
Was this helpful?
Thank you for voting!
Ice maker solenoid failure
5 of 6 people found this instruction helpful.
  • Robert from Mahopac, NY
  • Easy
  • Less than 15 mins
  • Screw drivers
several times I had to remove the ice maker door solenoid due to it sticking. I ordered a new one from parts select. Problem solved!!!
Was this helpful?
Thank you for voting!
broken auger in the bucket assembly.
6 of 9 people found this instruction helpful.
  • Chip from Mandeville, LA
  • Easy
  • Less than 15 mins
  • Nutdriver
I ordered the wrong part, the ice maker assembly, because your diagram was not marked properly. I returned the part and you credited my account. Thanks. Ordered the new bucket. It worked fine. Now I have ice and crushed Ice whenever I want. Thanks.

p.s. I didnt use any tools, but to satisfy you I select nut driver.
Was this helpful?
Thank you for voting!
evap fan not working.
6 of 9 people found this instruction helpful.
  • louis from floral park, NY
  • Really Easy
  • Less than 15 mins
  • Screw drivers
first i removed the three screws that covered the circuit board that was bad. then i removed the 6 connectors that went from the refrigerator to the board then popped out the old board , popped in the new board reconnected the circuit connectors covered everything back up and my refrigerator is back on line. this all took about 10 to 15 minutes time ... thank you for your product it really did the job..
Was this helpful?
Thank you for voting!
Ice maker was over filling and freezing the cubes together.
5 of 6 people found this instruction helpful.
  • Gary from Pickens, MS
  • Really Easy
  • 30 - 60 mins
  • Screw drivers
I turned water off at valve and unplugged refrigerator. I removed screws to remove cardboard cover at bottom. I removed screw holding duel inlet water valve bracket and pulled out valve. Then it's just a matter of exchanging electrical connections and water lines. The electrical connections unplug and plug in-red to red and blue to blue. The water lines are two different sizes so they can't be mixed up. Then reattach bracket and cardboard cover. Turn water back on and plug back in.
Was this helpful?
Thank you for voting!
Would not cool top or bottom
5 of 6 people found this instruction helpful.
  • David from White Pine, TN
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
Everything looked to be working but the compressor. As a pro checked every thing came down to a relay on the main board.

Just removed cover from back top left. marked and removed all wires. removed old board and installed new board very easy. Must read paper sent with it,
you may need to cut wires on some models.
Was this helpful?
Thank you for voting!
Water not dispensing
5 of 6 people found this instruction helpful.
  • Bob J from Platte City, MO
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
Background: My refrigerator was part of the class action law suit back in 2006. As a result both doors, the auger in the ice maker and a heating element in the freezer were all replaced.

Problem this time: Water was not dispensing.

Solution: Replaced the double outlet water valve in the back lower left portion of the refergerator. Water was coming into it from the water filter hose, but not coming out of it when the water dispenser in the front was engaged.

Further, I found that the coils in the back of the freezer were iced up and I therefore defrosted them with a heater. Thus, the original problem encountered with the law suit, did not get fixed by simply replacing the doors. That problem is still there. I think the defroster/heating element in the freezer is again not working.

However, I do now have water flowing again and the installation was, as others have described, very easy. Thanks for the online help.
Was this helpful?
Thank you for voting!
Ice maker door didn't open and close properly
5 of 6 people found this instruction helpful.
  • M Alan from Lebanon, TN
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
I removed the outer plate by sticking a very small screwdriver in the small holes at the bottom of the plate and pulling the plate toward me.
I then removed the 4 screws from the internal plate and pulled the plate toward me.
Then I romoved the 3 screws holding the old solenoid and unplugged it.
Next I put the new solenoid in place and replaced the three screws.
Finally I plugged in the solenoid and replaced the internal and external plates.
Was this helpful?
Thank you for voting!
Ice Maker would not fill.
5 of 6 people found this instruction helpful.
  • Charles from Keller, TX
  • Easy
  • 15 - 30 mins
  • Screw drivers
Was concerned that new icemaker was quite a bit different than the one we were replacing. Called GE to confirm it was correct.

Went ahead and installed the unit, using the supplied electric cable adapter.

A little difficult to deal with the extra cable, but everything worked OK and it's making ice normally.