DH40 - Instructions
Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Push on connectors and switch housing were different
0 of 1 people
found this instruction helpful.
-
Lester from Brazil, IN
- A Bit Difficult
- 30 - 60 mins
-
Screw drivers
The switch housing was not exactly the same for easy snap in. I removed the actual switch and installed it into the old housing. Then I found that the male pins were larger than the old ones. I chose to clip off the female connectores, strip the wires, and solder the wires to the pins on the switch. It was easier for me than attempting to
... Read more
change the push on connectors. For me, the actual switch was what I wanted and I fixed it my way. It was easy to do however some folks may want to change the push on connectors. Works great and saved me hundreds of dollars. Thanks.
Read less
Was this helpful?
Thank you for voting!
Error Code "01" and Bucket Full indication
0 of 1 people
found this instruction helpful.
-
Roger from Bangor, PA
- Really Easy
- 30 - 60 mins
-
Pliers, Screw drivers
Note: The error code and bucket full indication is a result of a malfunction in the sensor assembly (p/n 6877A30013M. To replace the sensor assembly, do the following: (1) remove rear panel; 2) remove the front panel cover and remove bucket; 3) remove main cover (covers center of unit); 4) Remove cover over PC board on top right side of u
... Read more
nit looking at it from the rear; 5)unplug sensor assembly connect on the main PC board; 6) remove clip that holds the temperature sensor on the compressor output tube ( this is a very strong clip)(also take a small piece of emery cloth and clean the output tube where the clip was attached); 7) use a tapered tool to spread the clip, just removed to, allow the temperature sensor to be removed from the clip; 8) unplug the bucket full switch connector; 9) remove the humidity sensor from the evaporator coil (just a snap-on connection; 10) remove the entire sensor assembly that was just disconnect during steps 1) thru 9) and reinstall the new assembly using the previous steps in reverse order; 11)Plug the unit in and all should be a go!
Read less
Was this helpful?
Thank you for voting!
Flashing light to empty bucket when not the case.
0 of 1 people
found this instruction helpful.
-
Allen from Wentzville, MO
- A Bit Difficult
- 1- 2 hours
-
Screw drivers
Replaced the sensor and solved the problem. I had a lot of difficulty with the case holding the circuit board,etc because no easy way to service. Seemes they could have made it easier with a removable panel. I actually cut the wires and re-attached the thermister later after routing. Did not use the other parts of the wiring.
Was this helpful?
Thank you for voting!
N/a
0 of 2 people
found this instruction helpful.
-
Scott from Wauseon, OH
- Really Easy
- 15 - 30 mins
-
Screw drivers
We had no problem installing the product.
Was this helpful?
Thank you for voting!
unit would not power on.
-
thomas from jamestown, RI
- Really Easy
- 15 - 30 mins
-
Screw drivers
removed the front cover housing the switch circut board. Removed the defective unit and plugged in the new part. Unit now works fine.
Was this helpful?
Thank you for voting!
01 on humidity display and full tank light flashing
-
milan from chardon, OH
- Really Easy
- Less than 15 mins
-
Screw drivers
Took the cover off and removed old sensor the new one plied wright in no problems anyone can do it
Was this helpful?
Thank you for voting!
bucket full light was blinking and dehumidifier would run for a few seconds then turn off
-
Larry from North Ridgeville, OH
- Easy
- 15 - 30 mins
-
Pliers, Screw drivers
remove outer shell and control panel. take cover off off electrical connection box. remove old sensor from front of condensing coil along with wiring harness to temperature sensor and bucket switch and circuit board. reinstall new sensor in the reverse procedure. reinstall covers.
Was this helpful?
Thank you for voting!
unit said water bucket was full when it was not
-
mel from MIDDLETOWN, PA
- A Bit Difficult
- 30 - 60 mins
-
Pliers, Screw drivers
taking apart and testing switch and connections, then searching online and finding the exact problem and part needed
Was this helpful?
Thank you for voting!