DH30 - Instructions
Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!
Search filter:
Clear Filter
Your search term must have 3 or more characters.
The Origional Humidistat Quit Working
10 of 17 people
found this instruction helpful.
-
James from Silver Bay, MN
- Really Easy
- Less than 15 mins
-
Screw drivers
The knob one turns to set the humidity level was removed. The two screws holding the top on were removed. The top was lifted and swung to the side. After noting which of the two wires went where on the humidistat the wires were removed. Small flat screwdrivers were used to pry back the plastic retainers on one side of the original fai
... Read more
led humidistat. The new one was put in place, the two wires were reattached. The knob was replaced. The top was positioned and its two retaining screws replaced. A magnetic phillips screwdriver was handy but not necessary. Piece of cake! Someone with ten thumbs could do it!! Thanks for the prompt courteous attention to the returned erroneous part! Dealing with partselect. Com was a pleasure. . . . . . Thanks!! P. S. The dehumidifier works like new now!!
Read less
Was this helpful?
Thank you for voting!
Says bucket full when it was not
7 of 10 people
found this instruction helpful.
-
Thomas from NEWPORT, RI
- Easy
- 30 - 60 mins
-
Screw drivers
The forums indicate that one solution for this problem is replacement of the sensor assembly, which is what I did. Upon switching the sensor assembly it DID work for one bucket full, but then went back to indicating bucket full when it isn't. Other fixes indicate changing the switch assembly, which I tried to do but the part has been disc
... Read more
ontinued. The only other item is replacement of the main computer, which the cost added to the cost of the sensor assembly would equal the cost of replacement of the appliance, so I won't go there.
Read less
Was this helpful?
Thank you for voting!
the humidity control broke
9 of 18 people
found this instruction helpful.
-
larry from tampa, FL
- Really Easy
- 15 - 30 mins
-
Screw drivers
Taking the case apart and replacing the control unit was a piece of cake. And the part arrived the very day after I ordered it.
Was this helpful?
Thank you for voting!
Machine would come on for a minute, then stop with message CR1
4 of 4 people
found this instruction helpful.
-
Judy from EVANSTON, IL
- Easy
- 30 - 60 mins
-
Pliers, Screw drivers
Googled message to see that it was probably the sensor or the bucket full button. The bucket button is no longer made, but the sensor was available, so I gambled and bought it to try. We removed the outer housing and old sensor. then replaced new sensor putting it in same place and following the path of the old one to plug in wires. th
... Read more
e whole housing had to be removed, could not just remove a section. Once replaced, plugged in to test, seemed to work. so replaced all the housing and screws. Unit is working again. Definitely worth the gamble, bc a tech would have been 3-4 times more expensive. My tenant was also confidant about being able to replace the sensor. After we did it, I think I could have done it too.
Read less
Was this helpful?
Thank you for voting!
bucket full light constantly blinking with error code 01 on the display
4 of 5 people
found this instruction helpful.
-
Seif from DETROIT, MI
- Easy
- 30 - 60 mins
-
Pliers, Screw drivers
Unscrew and detached front and back panels, and inside framework holding the sheet metal to the body, after removing the sheet metal, unscrew the box enclosing the control board, use needle nose pliers to unhook the sensor module from the board and place the new sensor into the spots where the old sensor was connected (thermostat area, hu
... Read more
midity Sensor, bucket switch, and control board). Close up the unit and your good to go.
Read less
Was this helpful?
Thank you for voting!
the dehumidifier was not shutting off when water level was full
5 of 9 people
found this instruction helpful.
-
Steven from Owings Mills, MD
- Really Easy
- Less than 15 mins
replaced a piece of the plastic at the top of the bucket that seems to be the water gauge. this seems to be fixed. we are very happy
Was this helpful?
Thank you for voting!
turbo stopped spinning
2 of 2 people
found this instruction helpful.
-
Cheryl from Bradner, OH
- Easy
- 15 - 30 mins
-
Screw drivers
Had to pop open the back. The back did not just unscrew and come off. It has to be pried off carefully. Took the turbo off and put the new one on.
Was this helpful?
Thank you for voting!
The rheostat controlled light failed
2 of 2 people
found this instruction helpful.
-
Barbara from HOUSTON, TX
- Really Easy
- 30 - 60 mins
-
Screw drivers
As I removed the broken part, I marked each wire indicating the color of the wire nut I would use for the installation of the replacement switch. With the new part, I connected the 2 yellow marked wires to the yellow supply wire. (It was "hot" - surprise!!) I connected 1 orange marked wire to one of the 2 corresponding orange wire. I then
... Read more
tested the switch and realized I had connected the light wire to the vent supply wire. I switched to the light supply wire, connected the fan control correctly. Life is good in my kitchen: cool and bright!
Read less
Was this helpful?
Thank you for voting!
unit would not continue to run after start up. I was getting a 67 code on the humidity level screen
2 of 3 people
found this instruction helpful.
-
John from SHICKSHINNY, PA
- Really Easy
- 15 - 30 mins
-
Pliers, Screw drivers
Ordered the new humidity sensor. Removed the sides and top all one piece of the dehumidifier by removing several screws. Removed the cover of the electric circuit box 2 screws. Removed old sensor by unplugging the wires. Installed the new sensor plugged in the 3 wires put the electric box cover back on. placed the sides and top back on s
... Read more
crewed them in and it works just fine.
Read less
Was this helpful?
Thank you for voting!
Didn't go as well as the last guy....
1 of 2 people
found this instruction helpful.
-
Kris from GREEN BAY, WI
- A Bit Difficult
- 30 - 60 mins
-
Nutdriver, Screw drivers
First....you need a metric nut driver...not a standard...this took me five trips to four stores to find. So if you have this model number don't think it is merely a screwdriver and a Phillips. After that the job was simple but the humidistat did not fix my dehumidifier. It was worth the $38 try ...but sadly off to buy a new one...
Was this helpful?
Thank you for voting!
broken roller wheels
1 of 2 people
found this instruction helpful.
-
MICHAEL from LEBANON, PA
- Really Easy
- Less than 15 mins
-
Pliers
released broken wheels from their position using a screwdriver and secured new ones w/ a pliers.
Was this helpful?
Thank you for voting!
float was missing
2 of 5 people
found this instruction helpful.
-
barbra from STERLING HTS, MI
- Really Easy
- Less than 15 mins
-
Screw drivers
pried off the plastic fastener with flat blade screw driver set new float in place then pressed plastic fastener back in place
Was this helpful?
Thank you for voting!
Two striped out screw heads
3 of 10 people
found this instruction helpful.
-
David from MCKINNEY, TX
- Easy
- Less than 15 mins
Purchased a screw extractor set from the local Ace Hardware (SpeedOut). Be sure and carefully follow the screw extractor instructions as written (counterclockwise turn). Removed old screws and replaced them with new screws supplied by PartSelect.
Was this helpful?
Thank you for voting!
Error Code "01" and Bucket Full indication
0 of 1 people
found this instruction helpful.
-
Roger from Bangor, PA
- Really Easy
- 30 - 60 mins
-
Pliers, Screw drivers
Note: The error code and bucket full indication is a result of a malfunction in the sensor assembly (p/n 6877A30013M. To replace the sensor assembly, do the following: (1) remove rear panel; 2) remove the front panel cover and remove bucket; 3) remove main cover (covers center of unit); 4) Remove cover over PC board on top right side of u
... Read more
nit looking at it from the rear; 5)unplug sensor assembly connect on the main PC board; 6) remove clip that holds the temperature sensor on the compressor output tube ( this is a very strong clip)(also take a small piece of emery cloth and clean the output tube where the clip was attached); 7) use a tapered tool to spread the clip, just removed to, allow the temperature sensor to be removed from the clip; 8) unplug the bucket full switch connector; 9) remove the humidity sensor from the evaporator coil (just a snap-on connection; 10) remove the entire sensor assembly that was just disconnect during steps 1) thru 9) and reinstall the new assembly using the previous steps in reverse order; 11)Plug the unit in and all should be a go!
Read less
Was this helpful?
Thank you for voting!
Push on connectors and switch housing were different
0 of 1 people
found this instruction helpful.
-
Lester from Brazil, IN
- A Bit Difficult
- 30 - 60 mins
-
Screw drivers
The switch housing was not exactly the same for easy snap in. I removed the actual switch and installed it into the old housing. Then I found that the male pins were larger than the old ones. I chose to clip off the female connectores, strip the wires, and solder the wires to the pins on the switch. It was easier for me than attempting to
... Read more
change the push on connectors. For me, the actual switch was what I wanted and I fixed it my way. It was easy to do however some folks may want to change the push on connectors. Works great and saved me hundreds of dollars. Thanks.
Read less
Was this helpful?
Thank you for voting!