defrost thermostat was open most of the time and didn't let the defrost element heat up.
Removed evaporator cover, unplug 2 wires to thermostat, unclipped it from the coil. Installed new themostat back the same way.
Parts Used:
Defrost Thermostat
  • Elvin from Gardner, KS
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
9 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Would not run. Everything in the freezer was spoiled.We were on vacation when it happened so we didn't know we had a problem until we got home. Big mess.
I knew from a problem years ago that the Thermostat was the likely cause so I ordered a new part and replaced it. Only need a phillips head screwdriver to remove the part and add the new one..
Parts Used:
Temperature Control Thermostat
  • Sonya from PUNTA GORDA, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
6 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The freezer was not keeping food frozen
I replaced the timer and the defrost thermostat. The defrost thermostat replacement was almost exactly like the training video here. The old part attached slightly differently. The most time consuming part was thawing out the heat exchanger, which was completely covered with ice, inside and out.

Compared to the training video, the timer took more work given its location. It was low to the ground and a bit difficult to get at around the other wires and parts. However, the new part fit perfectly. I just unplugged and unscrewed the old part then reversed those steps with the new one.
Parts Used:
DEFROST TIMER Defrost Thermostat
  • Jeffry from VERONA, WI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
6 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Squealing noise and bottom half of freezer only froze
I removed the shelves, unscrewed the cover panel of the fan motor and regulator dial, disconnected the fan motor from power, unscrewed 2 screws holding the motor to the mounting bracket and put the new motor in it's place. New motor had no thread in the mounting holes, so I put new tread in so I could use the 2 screws. Another option would have been to drill all the way through the mounting holes and use longer screws or bolts. Of course I turned the power off before I started repairs. Freezer runs like new now. Technicians wanted $400 for the job, while it cost me a mere $55 for the Motor.
Parts Used:
FAN MOTOR EVAP 115V
  • Walter from SALT LAKE CTY, UT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
6 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer was running too warm
Removed the old defrost timer by removing 4 screws on the holding bracket. Disconnected the wire harness. Reconnected the wire harness to the new part. Installed the new part with 2 screws on the top of the molded bracket. I am a 67 year old woman... easy-peasy. (the defost timer is located in the bottom left rear of the freezer.
Parts Used:
DEFROST TIMER
  • Jeanne from SAN ANTONIO, TX
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer was freezing solid
I first replaced the defrost timer about a week prior and it did not correct the problem. I then ordered the thermostat from partselect and within 15 minutes had the part installed. My refridgerator has been running correctly for a couple weeks.
Parts Used:
Defrost Thermostat
  • Matt from Cincinnati, OH
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Coming from the refrigerator, there was an intermittent "clicking noise", occurring about every 30 seconds. The frig. eventually failed .
I removed the back cover and removed the clip holding the compressor- run capacitor and start relay. I replaced these 2 components and clean the dust from the frig., and from the bottom of the floor. I replaced the back cover ; Loss about $300 worth of meat when when the frig. failed. Then I thought that, during these turbulent times, there are many which don't have a refrigerator or any meat to place in it, The refrigerator is "running" normal again.
Parts Used:
Run Capacitor - 120V
  • winifred from LOUISVILLE, KY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer would only run sometimes by turning the thermostat to highest position fully clockwise. Sometimes turning it full CW wouldn't turn on. Once the freezer would run on highest setting, it seemed that it wouldn't shut off. I put a thermometer inside and would read -15deg when running. +15-20deg.
Replaced thermostat and it fixed the problem. Freezer comes on and turns off automatically and regulates internal temperature around 2-5 degrees.
The hardest part was extending the coiled probe tubing and forming it to fit into clamp without kinking it.
Parts Used:
Temperature Control Thermostat
  • Rex from BEDFORD, WY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer stops freezing, sounds and looks normal,, no compressor or fan sounds
would take off working when the temp control was increase one number. Came here after I got to the number 7. Changed both parts the first time and temp control is working fine at 4. thanks for all the help
Parts Used:
Temperature Control Thermostat Run Capacitor - 120V
  • Blaine from PIERRE, SD
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer wouldn't shut off and wouldn't reach cold enough temperature.
Removed existing part, tested it, found it to be defective. OrderEd a new one and replaced the existing one.
Parts Used:
Defrost Thermostat
  • Tunis from NOLANVILLE, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer would frost up and not get cold enough to keep frozen.
Removed shelves ,removed panel on interior back wall with Philips screwdriver ,unplugged wire terminals slid thermostat off coil ,then reversed process to complete installation.
Parts Used:
Defrost Thermostat
  • Richard from SLIDELL, LA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
It wouldn't restart when it turned off
I changed the cooling control
Parts Used:
Temperature Control Thermostat
  • Mervin from BOYD, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer not cooling due to icing up of coil.
The timer in this older unit is clearly exposed at the back of the freezer underneath the freezer compartment. It is attached with two Phillips head screws. After the screws are removed, the timer can be unplugged and the new one plugged in. The new timer has an extra flange to allow it to be used on more than one model of freezer. In order to mount the timer in this unit, you have to remove the extra flange by carefully cutting it away from the timer body, in similar fashion to what's depicted in the online video. This will allow you to mount the new timer to the mounting plate using the two screws from the old timer.
Parts Used:
DEFROST TIMER
  • Thomas from GRANBURY, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No problems
It went exactly like your on line video. It took longer to defrost the freeze than it did to make the parts change out.
Parts Used:
DEFROST TIMER Defrost Thermostat
  • Steve from PRAIRIEVILLE, LA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer would not run or get cold
Temp control thermostat fixed problem many thanks to Part Select for help with this problem.Was able to save majority of food.
Parts Used:
Temperature Control Thermostat Run Capacitor - 120V
  • Donald from ANDERSON, IN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the CFUF21CDMB0
16 - 30 of 74