CFE28TP4MGW2 General Electric Refrigerator - Instructions
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Would not self defrost.
Remove the shelves then remove the back by removing the two screws at the top of the panel. Locate the temperature sensor on top of the coil. Cut the wires and replace with the new one. Use wire nuts and electrical tape to reconnect the wires.
Parts Used:
-
Greg from Rockwood, TN
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver
Was this instruction helpful to you?
Thank you for voting!
Refrigerator and freezer drawer would not maintain set temperature
Condenser fan motor was running slow. This was not a problem included in your list of possible problems. I thought that maybe the capacitor was bad but have no way to check it. So I ordered one. when I received it, I installed it. That was not the problem. So I ordered a fan motor and installed it. That was not the problem. So finally I ordered a control board and installed it. That solved the problem. So maybe you should put "cond.fan motor runs slow" in your list of possible faults and what causes that problem. Capacitor was easy to install, simply remove the cover plate, flip off retaining wire, unplug the capacitor and replace. Fan motor was a bit more difficult. It must be removed from mount after fan scroll is removed. Remove one screw that holds scroll, bend the top down and remove. Then pull hard on fan blade to remove it. It must be installed on new motor. Two screws in frame mount can be removed with some effort if you have a 1/4" drive ratchet with a Phillips screwdriver bit. Then pull frame open and install new motor. Push fan blade on new motor shaft hard. Replacing control board was easy. I used a pair of long nose pliers with 90 degree bend to get mounting pins closed to pull board off.
Parts Used:
-
James from Bel Air, MD
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Socket set
Was this instruction helpful to you?
Thank you for voting!
freezer and refrigerator wasn't cold
Replaced all the sensors in both the feezer and refrigerator.Even though it colder now it still is not cold enough.Freezer won't freeze items but is cold and refrigerator still not real cold
Parts Used:
-
Laura from Brentwood, MD
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Wrench set
Was this instruction helpful to you?
Thank you for voting!
Fridge/Freezer getting too warm
What an awesome site! After putting in my model number and finding the problem I was having, I simply picked the 2 parts that were most likely to solve the problem. I bought a defrost thermostat, and defrost heater. To a high certainty, they would solve my problem. They didn't however! I ended up having to buy a temperature sensor on another order a few weeks later when the problem resurfaced! My own fault. I should have bought it the first time. As others have written: the longest part of the job is defrosting the ice from the coil. One thing I did that I didn't see suggested: plug the drain hole below the coil. I put a couple towels in the bottom of the freezer and ran the hair dryer. Didn't take long. I read that the amount of water created will overflow the pan under the refrigerator, so I plugged the drain hole. Once you clean that mess up, the repair is pretty straight forward. Great site. Even through I had to make two separate purchases, I still saved a lot of money. Thanks!
Parts Used:
-
Nick from Burnt Cabins, PA
-
Difficulty Level:Easy
-
Total Repair Time:1- 2 hours
-
Tools:Screw drivers, Socket set
Was this instruction helpful to you?
Thank you for voting!
Refridgerator not cooling, freezer frosting over
First, I had to remove the freezer drawer front. This is 8 large phillips head screws. then remove the plastic cover over the drawer slides. to do this, remove the white center screw from the slide near where it attaches to the drawer front. then the plastic cover will slide off pushing to the rear of the slide. take off the slides from the freezer walls by removing the phillips screws and pulling them towards you. They have tabs/slots in the rear. remove the center tray support and support bars, too. the icemaker has to come out, that is just 2 phillips screws but you also have to disconnect the electrical connector. just squeeze the locking wings and rock/pull. a screw in the top center of the back panel comes out. Lift and pull the back panel out. The evaporator coil appears. The thermocouple is attached to the coil in the upper right. Cut that one's wires and take it out. Just cut back about an inch from the back of the thermocouple, there is not much slack. Seperate and strip the wires back about 3/8 inch. Do the same for the new thermocouple. I twisted the wires together and used a solder sleeve to join the wires. The sleeve is just a little plastic tube that has a ring of solder in it that melts with heat gun heat. You can join the wires using butt connectors or whatever method appeals to you. I just wound the extra wire and put a cable tie around it, there is plenty of hiding space in that area. Make sure the new thermocouple is contacting the coil firmly.At this point, for a test, I left everything apart, propped the drawer against the opening and plugged the fridge in. Note that the evaporator fan will not start spinning immediately! It will just sit there making little bumps like it wants to go. The temp in the coil has to get settled before the electronics in the refridge will tell the fan to spin. It takes maybe 20 minutes. Reassemble. Fridge and freezer work great. It does take several hours for all to get cold again.
Parts Used:
-
Bill from Warrenton, VA
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:1- 2 hours
-
Tools:Screw drivers
Was this instruction helpful to you?
Thank you for voting!
The frig was not cooling in main section or freezer
I ordered 3 temperature Sensors Part#PS304103 and viewed the video. Got there, opened the frig. and it looked totally different and no place in any part of this frig. that took these sensors as viewed on the video. Totally baffled why these parts were listed for this frig. there was no place in this frig that would access for these parts. Serial # was HR443071.Maybe this model is out of date for these parts. Trying to find someone who can repair it. Any ideas???Purchased this GE in 2008. Model #is GSS25WSTFSS Thanks, for your help. JIM
Parts Used:
-
James M. from Belfair, WA
-
Difficulty Level:Very Difficult
-
Total Repair Time:More than 2 hours
Was this instruction helpful to you?
Thank you for voting!
fridge to warm
-
Michelle from Chimacum, WA
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Pliers
Was this instruction helpful to you?
Thank you for voting!
refig light did not work
-
paul from east hanover, NJ
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
no light in freezer
-
christopher from collegeville, PA
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
Was this instruction helpful to you?
Thank you for voting!
Both the fridge aqnd freezer would not get cold.
Easy. Followed the video instrucations. the part was right there next to the compressor.
Parts Used:
-
Mary from Farmingdale, NY
-
Difficulty Level:Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
Was this instruction helpful to you?
Thank you for voting!
coils were icing up and refrigerator section was warm freezer was cold
Unplugged unit and removed vented cover over compressor section. The run capacitor is a simple fix 1 Phillips head screw and 2 spade wire connectors. For the temperature sensor I had to remove all drawers and the ice maker to remove the back cover to expose the condenser. Put a bowl at the drain stem in the rear of the unit and used a heat gun to defrost the coils on the condenser. Cut the wire about 3" from the sensor end . cut about the same off the new sensor stripped the wires put shrink wrap on each wire, attached butt connecors . heat gun for the shrink wrap and reassembled everything. Simple job that took about a half hour to do both. I will monitor the fridge for a couple of weeks to see if I need to change the control board.
Parts Used:
-
Chuck from TARRYTOWN, NY
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers
Was this instruction helpful to you?
Thank you for voting!
defrost problem (refrigerator/freezer not cooling)
After replacing the Defrost Thermostat, Defrost Heater Assembly, and the Main Board, I concluded that the problem must be the Defrost Thermistor, which I replaced in less than 10 minutes and it fixed the problem! I cut the wires on the old thermistor and connected the new one after stripping the wires and taped the new connections with electrical wire. Fast and easy repair (the last part anyway ;).
Parts Used:
-
Gordon from Sugar Grove, IL
-
Difficulty Level:Easy
-
Total Repair Time:More than 2 hours
-
Tools:Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
failed light switch
I started removing the switch by prying on the right side with a screwdriver, when it emerged enough I used pliers to finish removing it. I then unpluged rhe wires from the bad switch and pluged them on the new switch and "poped" it into the hole.
Parts Used:
-
Jules from Crowley, LA
-
Difficulty Level:Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
coil frosting up and refridgerator section was not cooling
took out shelves and removed the back plate my removing 2 screws with a nutdriver.removed the old defrost timer and defrost heater which was really easy.then installed the new ones.the video i watched on the website was really helpfull.
Parts Used:
-
Vernon from Harmony, NC
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Defroster stopped working and iced up evaporator coil
I have a GE Profile French door refrig. It's only about 4 yrs old and the defroster stopped working. I read the other repair stories and was able to narrow it down to either the temp sensor, defrost timer, or main board. The refrig section was up to about 47 degrees and freezer was around 25. I could tell it was trying to cool but couldn't. So I tried the temp sensor first. I cut and spliced the new sensor on the outlet of the Evap. Coil and it took about 15 mins. Turned refrig back on and waited. The coil started to ice over after about 5 hrs I left the back panel off so I could see if and when then heater kicked on. After about 8 hrs I looked in and saw a faint glow and water trickling down and running out the drain. Turned out the sensor was bad and wasn't telling the main board it needed to defrost. I would try the sensor if you are having the same issues before spending a lot of money on the main board, defrost heater and or timer.
Parts Used:
-
Brandon from Bruceton Mills, WV
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Pliers, Screw drivers, Socket set
Was this instruction helpful to you?
Thank you for voting!