freezer became frosty but refrigerator's camera didn'thave any coll at all.
After describing my problem PartSelect consultant emmidiately diagnost the problem and I ordered Evaporator Fan Motor. Along with purches order confirmation I got video how to install a new motor.
The hardest part was to connectthe ground wire becase space in that area was verylimited. Otherwise it was just like a walk in the park.
As soon as I installed motor and turned on the refrigirator, everything start working properly.
Thank you PartSelect, you sved me hundreds of dollars.
The hardest part was to connectthe ground wire becase space in that area was verylimited. Otherwise it was just like a walk in the park.
As soon as I installed motor and turned on the refrigirator, everything start working properly.
Thank you PartSelect, you sved me hundreds of dollars.
Parts Used:
-
Yakov from BROOKLYN, NY
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers, Socket set
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Not enough cold air in refrigerator
Remove food from freezer shelf and ice maker back panel4 screws remove old motor replace with new motor reinstall all removed parts. Plug in and fan instantly came on refrigerator working great since
Parts Used:
-
RICHARD from VENICE, FL
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
compressor not running
Removed the access panel on back of unit located the Run Capacitor on the compressor and removed the bad one and put the new one on and pugged refrigerator back in and it started up and works fine now
Parts Used:
-
Doug from Lancaster, CA
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer would not freeze
inst said,"50 pct of the time this calls for new capacitor," so we changed the capacitor. Same prob. It also said,"25 pct of the time it's the bi-metal thermostat" So we ordered it. We removed the plastic rear panel from inside the freezer comp. using small nut driver. Here we found much ICE surrounding the defrost unit, three inches thick. We thawed the whole mess. and the freezer has worked fine ever since. I think my habit of getting ice cubes from the inside container rather than from the ice cube dispenser, had kep t the freezer door open too much, interfering with the normal defrost cycle and allowing ice to build up over time so that it finally defeated the system. My new rule, "get ice cubes only from the front."
Parts Used:
-
Michael from HELENDALE, CA
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Very easy installation
The cover just popped in, no problem
Parts Used:
-
David from Woodstock, IL
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Warm fridge and freezer but compressor was running. No air distribution inside fridge
I turned breaker off to fridge, it was easier than pulling fridge out in camper. I took 4 screws out of back panel that revealed the evap fan, took 2 more screws out to take fan bracket off. Unplugged fan plug. Took fan blade off the non working evap motor and put it on the new evap motor. Put all the screws back in the reverse order and flipped the breaker and air started circulating.
Parts Used:
-
Brian from BURTON, MI
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
door hinge broke.
-
Bernard from DONALDSONVLLE, LA
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Screw drivers
2 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Plugged it in.
Not so good that was not the problem. Fan is not seized and all the lights work and display is not on but lights up as well. No start once plugged back in after 15 minutes of being unplugged. Nothing same no change.
Parts Used:
-
Adam from GLOVERSVILLE, NY
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Nutdriver
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
light did not work on the refrigerator side
bulbs were not burnt out. received the new switch in a few days. watch the short video, was good to see how it comes out. used a putty knife to release the defective switch, removed wires put them on the new one and posed the new switch back in. Not bad Part cost $11.00 7 dollars shipping so for 17 bucks it works great. nice to see what is inside the refer!
Parts Used:
-
David from GROVESPRING, MO
-
Difficulty Level:Easy
-
Total Repair Time:Less than 15 mins
1 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light switch broke off
We looked up the problem online with the model number of the refrigerator. We ordered the part and followed the video installation that was sent with the order and was found online prior to purchasing
Parts Used:
-
Kathy from TEMECULA, CA
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Pliers
1 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Rocker on switch broke off
Eased the putty knife under the edge of the switch housing and pried it off. Pulled two wires off the old terminals and hooked them onto the new one and reinstalled into the refrigerator body.
Parts Used:
-
David Barnes from ROSWELL, NM
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
1 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Doesn’t cool
-
Benjamin from WASCO, CA
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
1 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
I broke the cooling fan while cleaning the heat exchange area
Very simple, pulled old fan blade off and pushed new fan blade onto shaft. Perfect fit!
Parts Used:
-
Daniel from N TONAWANDA, NY
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
1 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
light staying on
A very cold and brittle switch in a 17 year old fridge. Used screwdrivers to pry out with some resistance Had to cut the molded plug in half and split wires, because replacement contacts were farther apart than the original. End result, works great.
Parts Used:
-
Cecelia from Beaver Dam, WI
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
0 of 1 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Internal light did not come on each time the door was opened.
After disconnecting the electricity. I followed the instructions as indicated in the "HOW TO" article on the website. I used a steel putty knife and pried the light switch out of its retaining hole. I worked the right side the most since this is the side with the retaining clip. After I removed the switch I transferred the two electrical outlets to the new switch and easily snapped it into place. Engaged the electric power and tested the switch.
Parts Used:
-
John from Jefferson Hills, PA
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
0 of 1 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!