freezer clod-fridge warm, coils were frosting up cutting off air flow
First unplug then remove all food and the ice cubes from the freezer only..Then removed the traysand then the 2 panel screws. Defrosted the coils with a hair dryer,removed the 2 screws holding the heater and then unplugged the wires from each side.Installed the new heater and now has been fine for 12 days now..The sensor- I just spliced it in the exact way the old sensor was wired.All seems fine so far. Was alot cheaper to buy the parts and install myself than to pay for 1 service call..
Parts Used:
Temperature Sensor Defrost Heater and Bracket Assembly
  • Greg from Windsor, WI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers, Socket set
105 of 133 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Repeatedly stick in defrost, raising temps in fridge and freezer for hours at a time, some times for days. Repair tech was called out twice to look into this problem, but the temps returned to normal both times before he arrived, therefore, he never could diagnose the problem with a certainity as wh
The main board is easy to get to behind the access plate. You will find seven different wire harness plugs, six which are white, that are impossible to remove without breaking the retaining clips which hold them in place....but that's OK.....you are throwing away the old board anyway, so nothing lost. The plugs will snap back into each of their respective terminal locations without a problem. Be sure to treat the four white, plastic pins that hold the board in place delicately....you will not want to mess those little dudes up!
Parts Used:
Main Electronic Control Board
  • Jerry from Otisco, IN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
96 of 121 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice dispenser quit working and kept making a clicking sound
All you have to do is replace the circuit board which is really easy. Still kinda mad because the fridge is less than 2 years old. If you hear the clicking noise its coming from the circuit board.
Parts Used:
Main Electronic Control Board
  • Ken from Gibson City, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Pliers
86 of 97 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator stopped freezing and cooling frige
Well, I first had a local service guy look at the frige. only to find out his opinion was to replace the entire unit, because the Mother board cost more than the unit was worth. Me not accepting that answer, decided to look on line for a part and availability as well as price. Surprise, Part Select had what I wanted. Now, on the back of the unit in the upper left hand corner is the access door for the mother board.Find it, but before proceeding disconnect the power supply from the wall receptacle. Remove the surrounding screws on the access door with a nut driver and the correct size METRIC socket. Disconnect the wiring connectors on both sides of the board. Now there are 4 plastic type (mine were white) retaining studs holding the board in place. BE CAREFUL not to break these as you gently pull the board off studs. Replace board with new one, and restore wire connectors in their perspective places. Each connector has a different amount of pins inside so connecting them is easy. I know nothing about refrigeration, and this was a piece of cake. Less than 15 min. Unit cools like never before!!!
Parts Used:
Main Electronic Control Board
  • DAVID R. from BATH, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
77 of 85 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice stalactites were drooling out of the icemaker and gumming up the cubes in the receiving tray.
I first shut off water flow to the fridge. Examination of the package (which was not exact in appearance to the original) demonstrated that the electrical connectors were well-insulated so I arrogantly and successfully proceded without disconnecting the power. My fridge is old enough that the model doesn't appear exactly on anyone's list so I wasn't alarmed that it took an extra 10 minutes or so to noodle out how to adapt the slightly different inlet cowling and electrical cord with extension, but the device is pretty simple.
Soon I loosened the two mounting screws with a nut driver, used a screwdriver to pry away the plastic snap-in housing over the electrical socket on the fridge inner wall and pulled away the electrical plug. The original water fill tube remained in its cavity, ready for re-use.
The new unit's mounting points matched the original screw locations perfectly, as did the fill cowling - which on the replacement icemaker has two possible attachment points. The new unit's electrical connector required an extension pigtail to adapt to my socket, but it was included in the package. The extra cable posed a minor cosmetic issue because it hangs in the collection basket a bit, but that will soon be remedied with a tie wrap.
After the water was restored and an anxious wait of a few hours, we had well-formed ice cubes that weren't all stuck together and the stalactites haven't reappeared.
Parts Used:
Ice Maker
  • Gerald from Benicia, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
89 of 122 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker stopped working
I unplugged the electrical connection. Then I removed the 2 screws holding the icemaker in place. I lifted out the old icemaker unit and put the new one in place. Then put the 2 screws back in and plugged in the new unit.

The icemaker started making ice very soon after turning the unit on.
Parts Used:
Ice Maker
  • Dan from West Bloomfield, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
82 of 109 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice jamming up in the ice maker unit because auger was broken
Remove Ice maker bin from the refrigerator and empty. Unscrew the three Phillips head screws that secure the front plate to the bin and gently lift and pull the tab that secures the interior portion of the plate until it clears the bin. Once you remove the front plate, it will expose two side tabs on the front of the bin which must be depressed so that the plastic insert that hold the auger in place can be removed. Isolate the auger with the from the unit by rotating the parts off the shaft. The ice crushing blades are attached to the auger and can easily be removed by twisting the plastic nut off with pliers. The cutting blades will now slip off the end (make sure you study the orientation of the blades as each piece will come off separately and make the job unpleasant when you go to put it back together). Now that the auger is out, just reverse the process and you have a "new" ice dispenser. Works like a charm. The diagram furnished by PartSelect was very helpful and accurate if you get a bit lost, especially when putting the crushing blades back together.
Parts Used:
BUCKET AUGER
  • Elaine from Healdsburg, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
77 of 95 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken ice maker part
used a screwdriver to remove screw and unplugged part. Plugged in new one and secured with a screw.
Simple
Parts Used:
Ice Maker
  • Laura Beth from Mandeville, LA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
76 of 99 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Recessed door on ice dispenser would stay open causing the freezer to frost up
I inserted the tip of a very small screwdriver from a eye glass repair kit into the three small holes under the panel near where the ice is dispensed. I never would have known about this simple procedure if it wasn't for the feedback you post from your parts cumtomers. Once I did this the front panel with the buttons on it poped off and it was just a matter of removing a few screws at that point. The wires from the new solenoid easily plugged into the board on the front panel. I would recommend changing the screws at the same time. The old one's worked but they were rusty. I feel the solenoid was my only problem but I changed all the parts in between the dispenser door and the solenoid just to be sure.
Parts Used:
Dispenser Door Solenoid Assembly Dispenser Door Assembly or Flapper Door Recess Retainer Dispenser Door Recess Crank Recess Door Spring
  • Turcotte's Housing Service, In from Newmarket, NH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
70 of 92 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Our refrigerator stops delivering ice both crushed and cube. The ice bin was full. I first thought the delivery motor was bad and then the water dispenser in the door stopped delivery. Decided at that point it was either the door panel swith board, cable or the main circuit board on the back of t
After further diagnosis decided the main circuit board was the likely culprit. Ordered a new one from PartSelect. It came in 2 days and took less than 30 minutes to install. Unplugged the refrig. Removed the old board cover with a nut driver. Removed the wiring cables (note their location on the board) and also there were a couple of cable plugs on my refrig that were not not hooked to anything on the board. Snapped the old board out and the new board in. Reinstalled the cables and then the board cover. Plugged the refrig in and back in business. PartSelect is a great website! The speed of delivery and available information just saved me $500 to $600 from a appliance repair shop.
Parts Used:
Main Electronic Control Board
  • david from colleyville, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
62 of 68 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Replaced the cracked plastic ice auger
Removed the ice bucket assembly and attempted to dismantle and re-assemble it the same as new
after replacing the auger. I wish the part was shipped with replacement instructions because a simple job turned into a major headache for me because of the following:
1) I did not realize that the the nylon nut at the end of the auger rod assembly has a reverse thread. By the time I had it removed using vice-grip pliers and a bench vice.....the nut threads were stripped.
2) When removing the nylon washers, spacers, metal cutters from the old auger rod, I grabbed the entire grouping hoping to drop them on the new auger rod as a group. While doing so, the pieces slipped out of my hand and It was very difficult to find the correct order of configuration even with the on-line parts photo. I would recommend that you number each part before removing them from the rod because there is only 1 way all of these pieces can be re-assembled to work as designed.
Parts Used:
BUCKET AUGER
  • Michael from Greenbelt, MD
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Pliers, Screw drivers
67 of 84 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water valve was leaking by and overfilling icemaker tray
Turned off the water supply valve to the refrigerator. Removed the rear access panel (6 screws) and the one screw mounting the water valve. Slid the water valve out and disconnected the two electrical plugs and two outlet tubes (slip/lock fit) and the inlet supply (ferrel nut). Connected the three tubes to the new valve, the two power plugs, slid valve back in place and reinstalled the mounting screw. Turned on the water supply valve back on and checked for leaks - none. Reinstalled the rear access panel and tightened all screws.
Checked the icemaker and cleaned the input tube and tray, ensured all were properly mounted and aligned. Restarted icemaker and and checked the operation periodically over the next day. All worked properly.
Parts Used:
Water Inlet Valve
  • Guy from Homestead, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Wrench (Adjustable)
60 of 67 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The evaporator fan motor stopped running, freezer was warmer than normal
First ,I placed all the frozen food from the freezer into the lower fridge compartment. Removed the main shelf. Removed the ice cube tray shelf. Removed the center plastic covers using a nut driver. Removed the complete inside back wall of the freezer to get access to the fan. Simply removed about 5 screws, and cut 3 tie straps that held the wiring in place. Unplugged the fan connector and removed fan with its brackets and placed them on the kitchen table. Then used the nut driver to remove 2 screws which hald the fan to its bracket. Simply pulled off the fan blades and pressed them onto the new motor. Mounted new motor onto the bracket. Reinstalled the fan assembly back into freezer. Reconnected the wiring and the fan began to run... BE CAREFUL NOT TO TOUCH THE FAN WITH YOUR FINGERS!
Finally replaced all the covers, panels, and shelf etc. and everything is once again nice and cold.
Parts Used:
Evaporator Fan Motor
  • David from Romeo, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
65 of 87 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Clicking noice from the motherboard
After advise from the expert, he was adamant the motherboard was the (via symptoms)problem. After receiving the replacement board (via FEDEX), I followed the easy to understand instructions. I did number the electrical plugs and mapped the connections on paper. The key to the rapid fix was to carefully read all of the instructions to verify which (if any) wires needed elimination, which in my case was none. I will definitely use this service in the future as the expense was affordable and after research, I estimate a savings between 55% to 60%.
Parts Used:
Main Electronic Control Board
  • John from Greer, SC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
56 of 60 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Bad Ice Auger Motor
Things I learned...remove only the two far left screws and one far right screw from the ice auger motor mounting plate. Disconnect both wiring harness connectors. With the assembly removed from the freezer, you'll need to get the motor seperated from the drive mechanism (fork). This was the most difficult part of the repair. The reason is that the fork (which is reverse threaded) cannot be unthreaded independantly of the motor shaft (ie. they both turn together). Locking pliers on the shaft only stripped metal from the shaft and did not supply enough torque to remove the fork. The way I finally did it was to take the old motor partially apart, then lock the gear case (keeping the shaft from rotating) with the motor's own splined internal rotor shaft. Once I finally got the fork apart from the motor shaft, swapping out motors was simple. You'll need to put the old plastic glove on the new motor to keep it dry. Also, the replacement motor I got from partselect.com did not come with threaded mounting bolt holes. Therefore, I had to use slightly larger self tapping screws I got from the hardware store. I also used locking washers as the assembly is subject to vibration.
Parts Used:
Auger Motor
  • Mark A. from Port Byron, IL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Pliers
57 of 67 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!