The door light socket was broken and hanging down
The refrigerator light in our Kenmore fridge has been flaky for a number of years. The slightest bump would knock it out of the hole it fits into leaving the bulb dangling. Usually since we were used to it, we could avoid bumping it so it was no real problem, but a recent visitor bumped it and it once again was hanging. I decided this time, to take a serious look at it and fix the problem for real. I had options, duct tape, hot glue gun, goop...or a new part! A quick search on the internet, and I found www.PartSelect.com I entered my model # , quickly found the correct part number. The part came 1 1/2 days after I ordered it. The repair was very simple, I unplugged the fridge, removed the wires from the spade connectors on the old light socket, and attached them to the new socket. I then pushed the socket into the hole, and with new spring clips, it snapped snuggly into place. The socket came with extra wire connectors which I didn't need, the socket fits multiple brands of appliances. It also came with a bulb protector, but that wasn't needed for my fridge either. I was very pleased with the speed and ease of the repair. No more dangling light bulbs!
Parts Used:
Light Socket Kit
  • David from Roanoke, VA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
6 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer constantly covered with ice not defrosting
I opened rear wall inside freezer (two screws) cut the wires on old thermostat and removed it. Then I attatched the new thermostat to the existing wires using wire nuts and electrical tape and slid it onto the copper tubing. Re-installed the rear wall. Freezer works like a charm and the refridgerator is also colder. Job completed in twenty minutes and Tim Allen has nothing on me. Mike Milne
Parts Used:
Bimetal Defrost Thermostat
  • michael from millstone, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
7 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Leakiong water from the freezer compartment into the lower refrigeration compartment
After unplugging the appliance, I unscrewed the screws in the bottom and the back of the freezer compartment and un-clipped the connector for the ice machine, which i do not have installed. I clipped the pink and brown wires and replace the switch with the new switch. unfortunately, the appliance is still dripping water from the freezer compartment. It worked for a couple of days then stopped working. Still looking for a true FIX.
Parts Used:
Bimetal Defrost Thermostat
  • Mark from indianapolis, IN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
7 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator light would not stay on
Removed the 2 screws holding the light bulb shield, then the 4 uolding the metal panel. Unplugged the olw door switch and replaced.
reassembled the pieces.
Parts Used:
Refrigerator Door Switch
  • Dave from Manchester Center, VT
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Socket set
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer froze and refrigerator wet
First took all frozen food out and than undid the screws that held back on--than cut the wires that held the piece and replaced it but also found that the plug was frozen so we thawed that out, that is why it took longer. Used air compressor to blow air and it broke it free and than we finished and put the food back after it got cold. So far it is working find and to beat all we received our part the next day so my husband could fix it that weekend--Thank you for the quick respond-
Patricia in Marengo Ohio
Parts Used:
Bimetal Defrost Thermostat
  • Patricia from Marengo, OH
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers, Socket set
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Lower Light Socket removed and Wires capped with wire nuts
My tenants moved out of my rental property and abandoned their refrigerator there. The freezer door would not close properly because someone had previously removed the lower door support bracket and failed to replace the lower bracket shim that positions the lower part of the freezer door properly out from the refrigerator cabinet causing the door gasket seal to bind before the freezer door was fully closed. I removed and replaced this lower door bracket with a new shim made up of serveral thicknesses of cardboard to achieve this spacing and freezer door now closes and seals properly. They had never connected a water supply to the refrigerator although this model is equiped with an ice maker and in door ice and cold water dispenser. The access panel on the back of the unit had been previously removed and discarded. I made up a new access panel from cardboard and connected the water line to the solenoid valve. Valve was so old it would barely open when valve energized and water flow was too slow to make proper sized ice cubes and fill a water glass. I purchased a new water solenoid valve and replaced ther original valve and cured that problem. Replacing the access panel cured an improper cooling problem because with panel removed, most of the air flow bypasses the condenser coils. Lastly I replaced the upper tubular light bulb and the lower light socket I purchased here and installed a 40 watt bulb in the new light socket. Presto! I was able to turn non working abandoned refrigerator into a workable unit.
Parts Used:
Light Socket Kit
  • Wayne from Arlington, TX
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    Less than 15 mins
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Raplaced switch
Repair went well,took about five to ten minutes to disconnect the power from the fridge removed the defective switch installed the new one ,reconnected the power,,,and Let there be light and there was light!
Parts Used:
Refrigerator Door Switch
  • Winston A from Brooklyn, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
fan bearnings wornout
Simple remove the fan and motor, plug in the new cord and screw in the new motor.
Parts Used:
Condenser Fan Motor Kit
  • Thomas from Grand Island, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Socket set
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
lights wouldn't come on/work in refrigerator
Referencing the info/schematics you have on your website, I unscrewed/unattached top-front panel (carefully), from behind the panel you have to detach the wires (2) from the switch, pushed "in" the switch to remove, put in new switch and attach wires to test BEFORE remounting panel. Tada!! Thank you PartSelect! You saved me at least $80...would have been at least $100 to have a repair person come to the house!
Parts Used:
Refrigerator Door Switch
  • Jane from Albuquerque, NM
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers, Socket set
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
condenser fan making growling noise
pulled fridge out, remove back cover, remove 4 screws holding fan put new fan in with new screws way easy dont call a repair man for this shipping was fast thank you for that
Parts Used:
Condenser Fan Motor Kit
  • Mark from Green River, WY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Noise when compressor was running
I recieved the replacement part the next day after ordering it. If you are some what mechanicaly talented this repair is very simple. The only tool that is needed is a nut driver. You may want to remove the bracket holding the water solenoid vavlves. Then you can pull them out of your way to remove the 3 screws holding the fan to the bracket. Once you remove the old fan motor just reverce your steps with the new motor. Check that all your screws are tight. Check to make sure that there are no wires in the way of the fan. Don't forget to attach the wire harness and re-attach the solenoid bracket. Ahh nice and quiet like new!
Parts Used:
Condenser Fan Motor Kit
  • John from Medina, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
7 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Crisper Glass Shelf
Took the glass shelf out of the fridge in our rental home to clean and it just shattered in our hands. Did a search online and found part select, phoned to make sure I was looking at the correct part, the lady on the phone was very helpful. I ordered the shelf using the next day service as we were returning home to the UK within 3 days so did not want to take the chance of not receiving it before we left. I got the notification the part had been dispatched, the part was delivered early next morning. Took the shelf out the package and placed in the tray, job done!. Great service will definately use again, have book marked the site.
Parts Used:
Crisper Drawer Glass
  • Andrea J from Davenport, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Raise side of fridge and slide 2x4 under side with broken wheel.
Remove back side cardboard access cover. About 6 dcrews need to be removed. Remove 9/16” bolt and lower compressor tray frame down to slide out wheel axel. Place wheel in slot and replace axel. Lift compressor tray and replace 9/16” bolt. Replace cardboard cover. Remove 2x4.
Parts Used:
ROLLER-CAB
  • Hans from OGDEN, UT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Socket set
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
I added an ice maker to a 20 year old refridgerator
I added an icemaker kit. Everything I needed was in the kit. The refrigerator was presetup for an icemaker it was just never added. The only problem I had was that the holes for attaching the water solenoid were not pre drilled so I had to drill them myself and use sheet metal screws. The icemaker is working great.
Parts Used:
ICEMAKER
  • Nicholas from WEST CHESTER, OH
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Socket set
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The old motor has built in wire harness. The new motor has connectors on it.
Remove and clean out everything from the freezer and unplug the refrigerator. Take out the wire shelf in the freezer. (The fan motor is behind the back wall of the freezer, SO YOU CAN KEEP THE REFRIGERATOR CLOSED). Pop off the little cover on the center of the plastic shroud. Remove the little screw and carefully remove the plastic shroud. Remove the plastic cover for the optional ice maker on the upper left corner of the back wall. Take out the two screws in the upper corners on the back wall of the freezer and the last two screws holding the fan motor. The fan motor won't drop, remove the back wall and you will see two screws holding the motor mount. Remover those two screws, and pop the bracket out and separate.Take the two rubber motor mounts off the ends of the old motor and install them on the new motor. (Now you will have to cut the wires off the old motor), unplug the little wire harness, strip the ends and crimp on wire connectors to plug them onto your new motor. Its an AC motor so it shouldn't matter which hot goes on which of the two terminals. JUST MAKE SURE THE GROUND IS CORRECT! (After reinstalling the motor, plug in the refrigerator, turn it on before installing the shroud and make sure the fan is blowing outward. If all is correct, turn the refrigerator off, unplug and finish assembling the freezer. I found the new motor seems to run more efficiently than the old one.
Parts Used:
Evaporator Fan Motor - 60Hz 120V
  • Leo from EAGLE, WI
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 8ET1WTKXKT05