Element would not heat up
Removed 2 screws located underneath the front lip of the range top. Lifted range top and supported. Removed the 2 screws at either end of the support bracket. This bracket holds the elements in position. Be careful not to let the elements fall out when removing. The elements are now free to replace. Swap out the old with the new and be sure to reconnect the wires to the correct terminals on the new element. I did 1 wire at a time so as to not make a mistake at reconnecting the wires. Then replace the support bracket with the 2 screws and lower the range top in place and put back the 2 screws that hold the range top in position. VOILA!! Success. It works. The wife is now happy again:)
Parts Used:
Radiant Element with Limiter - 1200W
  • Everett from Colchester, CT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
shorted out small element burner switch
First, I disconnected the electrical power by pulling apart the plug behind the range. Next, I removed the screws holding the service plate on back of the top panel.I removed the switch knob by gently pulling it from the stem. Underneath I found 2 screws holding the switch in the panel. I removed these with a phillips screwdriver.I was able to pull the entire switch out to the rear leaving all wires attached.The new switch looked different from the original and the wires were configured differently but the wires were clearly marked. By removing one at a time and placing it on the new switch to the corresponding marking,it was a simple matter to wire the switch.I reinstalled the switch in the panel,put back in the screws to hold the switch, slid the knob back on the stem, reinstalled the rear panel,and plugged the power cord back in.The switch worked perfectly.
Parts Used:
Infinite Burner Switch - Small Element - 240V
  • Alvie from Walnut Cove, NC
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
left terminal broke off from the base of the block causing circuit breaker to trip and not able to be re-set
Ensured breaker was off. My range is hot wired. Removed all cables from old terminal block with nutdriver. Used phillips head screw driver to remove old terminal block from back of range. replaced old terminal block with new one. Re-attached accessory cables to small terminals first, then the main cables to the terminal block using where necessary long nose pliers. It is important to make note of which cables are attached to each terminal of the block, so make a sketch PRIOR to removal. Also be careful how the cables are attached to the block. You are using 10 gauge cable with thick insulation. It is important that when pushing the range back into position the cable does not put too much pressure on the block as it will break it. That's exactly what happened to this last one. It probably cracked under the strain of the pressure of the cable and finally current running through it weakened it to the point where it broke off from the block causing it to short and trip the breaker.
Parts Used:
Terminal Block Kit
  • Fred from North Babylon, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!