lights wouldn't come on/work in refrigerator
Referencing the info/schematics you have on your website, I unscrewed/unattached top-front panel (carefully), from behind the panel you have to detach the wires (2) from the switch, pushed "in" the switch to remove, put in new switch and attach wires to test BEFORE remounting panel. Tada!! Thank you PartSelect! You saved me at least $80...would have been at least $100 to have a repair person come to the house!
Parts Used:
Refrigerator Door Switch
  • Jane from Albuquerque, NM
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers, Socket set
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer Door Gasket Leaking
Remove small 1/4 inch hex head screws around inner perimeter of door. You have to hold the gasket back to access them. The entire molded door liner/shelf comes off with the gasket. It took a little while to de-ice the fiberglass insulation that tucked into the door liner (the ice was a result of the leaking gasket). De-icing was achieved with first a heat gun to allow removal, then placed in the oven for a couple hours at 300F to melt and evaporate the moisture from the insulation. I also needed the heat gun to straighten/relax the new gasket, as it had taken on a permanent crumple from being stored in a smaller than actual sized box. Instructions to smooth the new gasket were included with the box. Finally, fit the new gasket around the perimeter of the door liner and re-install the door panel with the 1/4 inch hex screws.
Parts Used:
Freezer Door Gasket - Black
  • Clifford from Lincolnville, ME
  • Difficulty Level:
    Easy
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fill cup broke.
Very easy to order from parts select. Took seconds to replace.
Parts Used:
Water Fill Cup and Bearing
  • Aliki from Miami, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
6 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken roller
proped up frig, loosened screws, cut pin, installed rooler w/ new pin, rounded pin end, reistalled, lowered frig...everyone happy, thanks again partselect.
Parts Used:
Roller Pin Single Roller
  • John from Capac, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker dripped water into ice bin, freeezing into large block of ice,
turn off water and unplug fridge. remove ice maker bottom mounting screw. just loosen the 2 top mounting screws. unplug wire harness from back of fridge. remove old icemaker from freezer compartment. once removed, salvage square endcover and reinstall on new maker. unfasten wire harness from old maker and reinsatll on new one. reinsert thermal wire in new ice maker holding bracket. remove second wiring bracket and reinstall on new maker to hold remaining wires (not mentioned on "how to-" video). remove old ice maker on/off bale and reinstall on new one. remount new maker to top mounting screws, reinsert harness plug into fridge. replace bottom screw,
Parts Used:
Replacement Ice Maker
  • charles from PHOENIX, AZ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridge and Freezer getting too warm.
In Freezer, removed the 3 screws hold up the dial to select the temperature. Once this is lowered you see the Cold Control Thermostat. New one was a bit different, but still fit. I carefully bent the sensor wire to come around to the front of the so it would fit. Slide the plastic tube over the sensor wire. I guessed on the Red and Yellow wires. I don't know if it matters if this is AC. I think I had the Red closest to the front. 2 prongs for the ground, but just need the small one. Put is all back together and it is working great.
Parts Used:
Cold Control Thermostat
  • Ted from NEDERLAND, CO
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrig began to trip the GFI circuit in the garage. When plugged into a house interior circuit the lights and fan ran but no cooling in either the freezer or frig.
First of all I want to thank Michael from Carlisle,PA and this site for publishing Michael's info on the wiring specifics on the new 3 connector Start Relay ( WP2262185 ). The original relay only has 2 connectors The 2 orange wires which are combined to one female connector need to be clipped and separated each to its own connector. Refer to Michael's blog as to which wire goes to which connector on the Start Relay. I replaced the Run Capacitor, Start Relay and Overload just to be safe. The Start Relay was the actual culprit.Thank you for an excellent website!
Parts Used:
Run Capacitor
  • riley from CAVE CREEK, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Socket set
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
shut off arm was broke and so was bracket
i just took the prts apart and replaced with new part really easy and saved $185.00 easy as pie
Parts Used:
Ice Maker Shut-Off Arm Water Fill Cup and Bearing
  • brandon from Cedar Rapids, IA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
12 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The refrigerator stopped running
I was told to order the run capacitor and the technician thought it would repair the refrigerator; but it did not. The appliance technician had to take the run capacitor off and install what he called a "hard start" and the refrigerator is operating right now.
Parts Used:
Run Capacitor
  • Barbara H. from South Hill, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
4 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
gasket not sealing
removed screws holding original gasket. removed gasket. placed new gasket on door and replaced screws. A little tricky getting new gasket in position before screws. patience!
Parts Used:
Freezer Door Gasket - Black
  • David from San Rafael, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker stopped working
After checking the water valves ordered new ice maker. received the part three days after ordering! Clearing out food, removing the old one and installing the new unit took under 15 minutes. Everything went fine.
Parts Used:
Replacement Ice Maker
  • Raymond from Panama City Beach, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Old Ice Maker failed
I removed the old ice maker and during the short disassembly noticed a burned out connection to the heater element that allows the ice to be broken free of the tray and dumped into the bin. Part Select had a new unit to me next day! I had watched their short install video, and read some of the user comments, already. Re-installing the new unit was a snap, and just as the video had described except for the mount bracket. The only thing that concerned me was that the new unit did not immediately do anything. I began to investigate and found that the flexible water "chute" connection had ice in it! I unplugged the refer, unscrewed the water filter and drained it. I disconnected the water feed on the outside back of the unit as well to make sure water could flow easily to the ice maker port. I filled the water filter with boiling hot water and replaced it, I plugged in the refer, and reprogrammed the date and time. Several hours later I checked the ice maker and it was -- making ice!
Parts Used:
Replacement Ice Maker
  • John from Gurnee, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker stopped functioning
Part received was what I needed. There was one issue--the 'feed' opening to receive water and direct it into the ice tray was a side feed and what I needed was a back feed. That means I had to do some exchanging of parts to make it work. That exercise took more time that the actual installation.
Parts Used:
Replacement Ice Maker
  • richard from colorado springs, CO
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Screw drivers, Socket set
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker was over filling and causing water to flow into ice dispenser and freezing it al together
First turned off the water and unplugged the refrigerator and then removed the old ice maker by first removing the side cover plate and then next removed the ice level detector. Remove the screws that hold the ice maker in place and rotating it somewhat soas to gain access to the wires and then unplugged them. Next I had to modify the way the water comes into the new icemaker by adapting a CPVC street ell to fit into the hole on the side and then hook up the water supply. Installation is just the reverse of removal.
Parts Used:
Replacement Ice Maker
  • Michael from Moore, OK
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light switch wasn't working.. As I would close the door I would notice our frig light wasn't going off...
I simply removed the old switch by gently pulling down on the old switch with a screwdriver. When it was about half way out I just gently pulled down on the old switch and it popped out... I removed the two connectors attached to the old switch by pulling on the connectors with a pliers...I tried using my fingers but wasn't able to pull the connectors off so I used pliers. It worked perfectly.. When pulling off the old connectors, make sure you attach the new switch to the same tabs on the new switch... It was very easy to do and took under 5 mins.....The light switch works perfect....P.S. You should unplug the frig while making the connection just in case....Safety first....!!!
Parts Used:
Refrigerator Door Switch
  • David from Hemet, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!