The water supply line to the ice maker kept popping off after I replaced the water filter because an "ice plug" had formed in the fill tube, unbeknownst to me.
1. Turn your water OFF and pull the refrigerator out from the wall so you can access the back.
2. Use pliers to remove tubing clamp.
3. Remove old water fill tube.
4. I used a putty knife to gently pry out the old fill tube from the back of the refrigerator. Once the fill tube pulls out about 1/4 to 1/2", then you can gently pull the remainder of the tube out by hand. Once I removed my "old" fill tube, that is when I saw the "ice plug" that was causing pressure in the water supply line and caused my water line to pop off.
5. Install new fill tube. The end that goes in first needs to go through a small "ring" inside the freezer (this "ring" is not encountered until the fill tube only has about one more inch to be inserted into the back of the refigerator. I could barely see this "ring" if I opened the freezer drawer and stuck my head in as far as I could. I had to gently rotate the new fill tube until it cleared the "ring". You will feel some resistance until it lines up properly.
6. Snugly push in the part that stays on the outside of the refrigerator until it looks like it is sealed.
7. Gently push up the water fill tube where it belongs in the new part and replace the tubing clamp.
8. Turn your water on and make sure there are no leaks (I left my refrigerator out for about an hour).
9. Push your refrigerator back in place.
Parts Used:
Elbow, Fill Tube
  • Michael from TAKOMA PARK, MD
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fill cup broke.
Very easy to order from parts select. Took seconds to replace.
Parts Used:
Water Fill Cup and Bearing
  • Aliki from Miami, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
6 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
leaking ice maker,big chunks ot ice were forming and had to remove them 2-3 times a day
removed old ice maker by taking out a couple of screws in the back of freezer,when new ice maker arrived i saw that it didn't have the same hose apparatus as old one so I easily took apart old one then took apart new one and switched them out-very-- easily done for a 61 yr old lady I might add-- also had to reinstall ice maker arm off old ice maker as new one does not come with one Then installed new ice maker in freezer I am very very pleased,sure saved a lot of money doing it my self
Parts Used:
Replacement Ice Maker
  • Linda from Johnson City, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker just stopped making ice
This was the third icemaker replaced since January 1999. Improvement need to be made in the design of the icemaker so that more than 2-3 years of life is available.
The most difficult part was disconnecting the power plug in the back of the icemaker. You must squeeze the upper and lower tabs together and pull out at the same time to disconnect. Once this is done, take out one nut head screw, lift up on the icemaker and remove from the hanger. Be careful that you don't break the plastic tabs on the hangers. Replace new icemaker in reverse, feed water supply where it must go in the back, resnap onto hangers, replace the nut head screw and snap in the power plug. It took about 2 hours before the icemaker began making ice. It has been working fine ever since. PS. I saved about $200.00 over having a repairman come in and replace the unit.
Parts Used:
Replacement Ice Maker
  • Thomas from Valencia, PA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water overflowing ice maker
Removed the 3 screws that hold the ice maker in place and remove the cover and level wire. Put the cover and wire on new part and install the 3 screws. Had ice within 1 hour. A very easy job for the do it yourselfer. Suspect the heat coil that melts the cubes was not working in the old unit and cubes stayed in the tray.
Parts Used:
Replacement Ice Maker
  • James from Denver, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
lights wouldn't come on/work in refrigerator
Referencing the info/schematics you have on your website, I unscrewed/unattached top-front panel (carefully), from behind the panel you have to detach the wires (2) from the switch, pushed "in" the switch to remove, put in new switch and attach wires to test BEFORE remounting panel. Tada!! Thank you PartSelect! You saved me at least $80...would have been at least $100 to have a repair person come to the house!
Parts Used:
Refrigerator Door Switch
  • Jane from Albuquerque, NM
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers, Socket set
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Raplaced switch
Repair went well,took about five to ten minutes to disconnect the power from the fridge removed the defective switch installed the new one ,reconnected the power,,,and Let there be light and there was light!
Parts Used:
Refrigerator Door Switch
  • Winston A from Brooklyn, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water filter was getting clogged
The filter is self-clogged when you un-wind it for replacement, so no complicated system shut-off was required in order to replace it.
Parts Used:
Refrigerator Water Filter
  • Raymond from Annapolis, MD
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Old fill tube was blocked
Cut old fill tube into pieces, removed and replaced with new tube. Extremely easy.
Parts Used:
Elbow, Fill Tube
  • David from VESTAL, NY
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker dripped water into ice bin, freeezing into large block of ice,
turn off water and unplug fridge. remove ice maker bottom mounting screw. just loosen the 2 top mounting screws. unplug wire harness from back of fridge. remove old icemaker from freezer compartment. once removed, salvage square endcover and reinstall on new maker. unfasten wire harness from old maker and reinsatll on new one. reinsert thermal wire in new ice maker holding bracket. remove second wiring bracket and reinstall on new maker to hold remaining wires (not mentioned on "how to-" video). remove old ice maker on/off bale and reinstall on new one. remount new maker to top mounting screws, reinsert harness plug into fridge. replace bottom screw,
Parts Used:
Replacement Ice Maker
  • charles from PHOENIX, AZ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridge and Freezer getting too warm.
In Freezer, removed the 3 screws hold up the dial to select the temperature. Once this is lowered you see the Cold Control Thermostat. New one was a bit different, but still fit. I carefully bent the sensor wire to come around to the front of the so it would fit. Slide the plastic tube over the sensor wire. I guessed on the Red and Yellow wires. I don't know if it matters if this is AC. I think I had the Red closest to the front. 2 prongs for the ground, but just need the small one. Put is all back together and it is working great.
Parts Used:
Cold Control Thermostat
  • Ted from NEDERLAND, CO
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Both compartments of the refrigerator were warm.
We came home from a long vacation to discover a warm refrigerator with its contents in various stages of decay.

Turning the freezer thermostat to its warmest setting then back to cold generated clicks, and after a few tries the compressor started and cooled the refrigerator to its normal cold temperatures. But… later the compressor again failed to start, and everything warmed back up again. With persistence and turning the thermostat up and down several times a day, we could keep the fridge cold.

It was time to order parts. We needed a new start relay and capacitor for the compressor. For our Amana ARB2214CW a start relay (WP12555902) and capacitor (WP65889-4) were listed on the first page of the Partselect parts list for my refrigerator. I ordered them, received them, removed the old capacitor and start relay (which rattled when shaken). and prepared to install my new parts. The new start relay did not match the old. The old start relay fit my wiring which had a single plug with two small female spade connectors in the plug. The new start relay required wiring with two separate female spade connectors; one the normal size and one larger. Phone calls to Partselect and to Westinghouse shed no light on the discrepancy. On the second page of the Partselect parts list was a combination of a start relay and a capacitor (W10613606) that matched my electrical connector. I could see the connection in the photograph. I ordered it and it fit. Easy peazy. That fixed the compressor start problem. Every time the freezer thermostat clicked on, the compressor started. Success.

But… from our troubleshooting we now had a thermometer the freezer, and it was obvious that the temperature difference between the cold point where the thermostat turned the compressor off and the warm point where the thermostat restarted the compressor was much too wide. In addition, the knob was hard to turn and was sticky as it turned. Oiling it fixed the sticky knob problem but not the wide temperature difference problem. I ordered a new freezer thermostat (WP67003000), received it, installed it, and all is now fine with my refrigerator. The new thermostat was physically a little different from the original, but it fit and worked.

I returned the first compressor start relay and capacitor and received a refund including the shipping charge.
Parts Used:
Compressor Start Device and Capacitor
  • Bill from KINGSPORT, TN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
shut off arm was broke and so was bracket
i just took the prts apart and replaced with new part really easy and saved $185.00 easy as pie
Parts Used:
Ice Maker Shut-Off Arm Water Fill Cup and Bearing
  • brandon from Cedar Rapids, IA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
12 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light switch wasn't working.. As I would close the door I would notice our frig light wasn't going off...
I simply removed the old switch by gently pulling down on the old switch with a screwdriver. When it was about half way out I just gently pulled down on the old switch and it popped out... I removed the two connectors attached to the old switch by pulling on the connectors with a pliers...I tried using my fingers but wasn't able to pull the connectors off so I used pliers. It worked perfectly.. When pulling off the old connectors, make sure you attach the new switch to the same tabs on the new switch... It was very easy to do and took under 5 mins.....The light switch works perfect....P.S. You should unplug the frig while making the connection just in case....Safety first....!!!
Parts Used:
Refrigerator Door Switch
  • David from Hemet, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker was over filling and causing water to flow into ice dispenser and freezing it al together
First turned off the water and unplugged the refrigerator and then removed the old ice maker by first removing the side cover plate and then next removed the ice level detector. Remove the screws that hold the ice maker in place and rotating it somewhat soas to gain access to the wires and then unplugged them. Next I had to modify the way the water comes into the new icemaker by adapting a CPVC street ell to fit into the hole on the side and then hook up the water supply. Installation is just the reverse of removal.
Parts Used:
Replacement Ice Maker
  • Michael from Moore, OK
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!