it quit working-refer-freezer-part,fan keeped running
pulled out switchs verified part #'s-ordered replacements- its actually plug in switches and very simple
Parts Used:
Overload/ptc - 5 speed Capacitor
  • jim from buckeye, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
21 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice built up on coils. Fridge was warm.
No instructions came with new parts. Access to element was impossible until I accidentally discovered that the two styrofoam cushions at the ends of the coils were removable. Once removed, access to the heater and thermostat was very easy.

Unplug appliance, remove freezer shelf, cold air ducts, back of freezer, disconnect light, (My model does not have ice maker. This may also need to be disconnected.)
1.Remove styrofoam cushions at end of coils
2.Locate element between bottom two coils
3.Disconnect the male/female connections
4.Remove support clip under center of element
5.Remove element
6.Replace new element in reverse

Connecting the thermostat wires was challenging because they were somewhat behind the coils.

1.With styrofoam removed, unclip thermostat from coil
2.Carefully cut wires (leave enough to connect new wires)
3.Connect new thermostat wires (color of wires matched on my fridge)
4.Clip new thermostat in place
5.Replace styrofoam
6.Button it all up

With these steps, this job would take maybe 30 minutes; somewhat longer if your model has an icemaker.

Hope this helps.
Parts Used:
Defrost Thermostat Defrost Heater
  • Neil from Boise, ID
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers
20 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator door handle broke
Simply removed the screws and pulled the old handle off and aligned the new handle with the holes and replaced the two screws.
Parts Used:
Fresh Food Door Handle - White
  • Barbara from Philadelphia, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
21 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The refrigirator light would not come on.
Poped out with screwdriver the old swithch and unplugged the two wires. Plugged in the wires to the new swithch and pushed it back in the hole where the old switch was before.
Parts Used:
Light Switch
  • Jania from Novato, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
24 of 38 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Neeed extra shelves for new purchased refrigerator
Simple install. .
Parts Used:
Stationary Wire Shelf
  • Hollis from Daphne, AL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
22 of 34 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The condensor fan in the unit appeared to have been chewed by a mouse and would not function and the lower door was too low.
The condensor fan in the unit appeared to have been chewed by a mouse and would not function. We had a service call to verify this and ordered the parts. Delivery was extremely quick and we were able to complete the repair and place the unit back into service within 2 hours.

All that was necessary was to remove the bottom cardboard cover, replace the fan and grommets, and replace the door bushings.

Thanks!!
Parts Used:
Compression Ring Condenser Fan Motor Evaporator/Condensor Fan Grommet Door Hinge Nylon Washer
  • Eugene from Marion, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers, Socket set
20 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Switch failed on which kept the refrigerator warm due to heat generatered by light bulbs.
While the switch did last for 9 years, the design is poor due to the failure mode. The failure should be to fail off or not able to turn on the lights which would be inconvenient but would not warm the refrigerator contents. Arcing at the contacts eventually caused the switch to "weld" closed. It is not obvious that this is occurring so it took some time to recognize why the temp inside the ref was high while the freezer was OK. Replacing the switch was easy once it was recognized as the problem. All that was required to replace the switch was to remove the screws holding a fiber cover and then pulling off the aluminum cap which covered the switches. Unplug the switch an squeeze the keeper on the switch to release it and pull down. Pop the replacement switch in place and plug the wires harness back in. All in all it took much less time to replace than it has to write this up. T Pope
Parts Used:
Light Switch
  • Terry from Simi Valley, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
18 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Motor was squeezing. Needed to be replaced.
Easy Peasey. Had to make one adjustment 24 hours later. Set the fan too far into the shroud. After the adjustment it works great!!!
Parts Used:
Access Cover Condenser Fan Motor Evaporator/Condensor Fan Grommet
  • Mark from BENICIA, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Socket set, Wrench (Adjustable)
14 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Old door gasket torn/problematic; moisture in fridge
Referenced a couple of videos first, held up the new gasket to ensure fit, then carefully pulled the old gasket off by hand. Wiped down the ridges/edges of the door, then installed new gasket first on opposite corners then along all sides. Simply pressed in to the door ridges/bracket. Used a putty knife to ensure the edge of gasket was not folded under itself, and the blunt edge of the handle to ensure it was snugly installed all the way around. Didn’t have to remove the door as I had expected to. Very easy and took maybe 30 mins.
Parts Used:
Fresh Food Door Gasket
  • Joe from BROOKLINE, MA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
14 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
we had a power surge that killed the fan motor
I removed the fan housing , this was the hardest part , this took loosining two screws and snapping the housing loose , and there it was , settin there Idle and the coils were all ice , I let the coils thaw while I unscrewed the fan mount from the back wall of the freezer , then pulled the fan and mount out far enough to snap the wire connector loose, then I removed the two screws that hold the motor to the mount , the new fan motor comes without the blade so the blade is removed by pulling fairly had on the center off the shaft , the old motor is taken out of the mount , the new one replaces it perfectly , then the screws are replaced and tightenen , then the blade is pushed back on the shaft , the motor and mount are placed back on the back wall of the freezer department and screwed in place , the wires connected , then the housing is snapped back in place and the screws tightened , turn the dial to cool or number 2 or 3 and " bingo " it,s just like new , I can thank part select for speedy service and delivery
Parts Used:
Evaporator Fan Motor
  • Richard from Wellsboro, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
13 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Existing light switch was hard to remove.
The existing light switch was very hard to remove. I ended up having to grab it with a pair of pliers and pull it out. Once it was out, it was very easy to put in the replacement and it seems to be working fine.
Parts Used:
Light Switch
  • Stephen from Jupiter, FL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
14 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fan Motor stopped working
Not only was finding the part rediculously easy for a person who has never done this type of thing...the repair was a sinch!! I will always return to this company for help with home equipment repairs. I saved so much money doing it this way. :) thanks guys!
Parts Used:
Evaporator Fan Motor
  • connie from omaha, AR
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
12 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
malfunction of the cold control (wearing out after 15 years)
1. Disconnected 120 VAC power supply from refrigerator. 2. Removed 2 philip screws from horizonal panel containing the thermostat. (Panel is in refrigerator section). 3. Removed plug module from panel which freed the panel which allowed me to remove panel to do repair. 4. Removed wires from thermostat (cold control), and mechanically removed thermostat from panel and installed new cold control (thermostat). Replaced wires on control. 5. Replaced panel and reinstalled 2 philips screws. 6. time to repair about 15 minutes.
Parts Used:
Temperature Control
  • john from Philadelphia, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
12 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Interior light needed replaced
Unplugged the appliance for safety. Removed two 1/4" screws that held the assembly in place. Carefully removed the wire guard that retains the glass shield. Unscrewed old light bulb and replaced with new part. Reversed the steps after cleaning glass cover.
Parts Used:
Light Bulb - 40W
  • Leo from TWIN FALLS, ID
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
15 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
botton half of refrigerator not cooling
easy as 1.2.3 remove and replace before even thinking. just to let you know i also do this for a living but it is one of the most difficult thing when you have to stop and fix your own
Parts Used:
Defrost Timer - 120V 60Hz
  • HANCEL from ELMONT, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
25 of 55 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 38341FBMERWW
16 - 30 of 218