Ice maker ot making ice
18 of 31 people
found this instruction helpful.
-
Barry from Phoenix, AZ
- Easy
- 15 - 30 mins
-
Nutdriver
First I replaced the double valve because the ice maker was not filling with water. It still did not work. Then I replaced the ice maker itself. This worked and was relatively easy to replace. I had to use the water fill "slide" from the old ice maker. The new one was too narrow and it leaked water into the freezer.
Was this helpful?
Thank you for voting!
Steady drip of water out of the water valve
14 of 19 people
found this instruction helpful.
-
Janet from Weston, FL
- Really Easy
- 15 - 30 mins
-
Pliers, Screw drivers, Wrench set
I unplugged the refrigerator and removed the black fiberboard panel at the back of the unit. I turned off the water at the wall and disconnected the copper water line from the unit.
One bolt holds the valve assembly in place. Once the bolt is removed you simply pull the unit out of the refrigerator. I took the time to mark ... Read more all electrical connections and water lines (1, 2, 3, etc.) and wrote the corresponding numbers on the new valve unit. I unplugged the electrical connections and removed all water lines by gently squeezing them with the pliers and pulling them out of the old valve.
After everything was disconnected I connected the new valve. The numbering system made it easy to know exactly which plug/line went where and it was reconnected in less than 2 mins. I slid the unit back, replaced the single bolt holding the unit, reconnected the main copper water line, turned it on, placed the fiberboard back in place and was done.
We had an estimate from a refrigerator repairman of $275 to change this valve, parts & labor. We thought it was ridiculously high and decided to attempt the repair ourselves. Best decision we ever made and saved a fortune.
This is definitely an easy fix. Go for it!
One bolt holds the valve assembly in place. Once the bolt is removed you simply pull the unit out of the refrigerator. I took the time to mark ... Read more all electrical connections and water lines (1, 2, 3, etc.) and wrote the corresponding numbers on the new valve unit. I unplugged the electrical connections and removed all water lines by gently squeezing them with the pliers and pulling them out of the old valve.
After everything was disconnected I connected the new valve. The numbering system made it easy to know exactly which plug/line went where and it was reconnected in less than 2 mins. I slid the unit back, replaced the single bolt holding the unit, reconnected the main copper water line, turned it on, placed the fiberboard back in place and was done.
We had an estimate from a refrigerator repairman of $275 to change this valve, parts & labor. We thought it was ridiculously high and decided to attempt the repair ourselves. Best decision we ever made and saved a fortune.
This is definitely an easy fix. Go for it!
Read less
Was this helpful?
Thank you for voting!
ice would not dispense
14 of 19 people
found this instruction helpful.
-
john from montgomery, TX
- Really Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers, Socket set
I removed 6 screws, unplugged assembly that had motor attached,removed from fridg,replaced motor and reinstalled assembly, putting back 6 screws.works like new.
thanks.
thanks.
Was this helpful?
Thank you for voting!
Noisey Motor, Bearings Out, Dying
12 of 13 people
found this instruction helpful.
-
PERRY from VANDERBILT, MI
- Easy
- More than 2 hours
-
Nutdriver, Wrench set
Remove back cover, exposing fan motor. Turn off power, remove nut on fan blades. Remove fan carefully, do not bend. Unhook wiring harness. Remove three screws that hold the motor on the back frame. Remove old motor, install new. Carefully, reinstall fan blades, hook up wiring, and your ready for tryout. Also do some cleaning whil
... Read more
e your there. Clean old fan blades with hot soapy water or contact cleaner. Everything runs better clean!
Read less
Was this helpful?
Thank you for voting!
water leak from valve
23 of 47 people
found this instruction helpful.
-
MILTON from MARIETTA, GA
- Really Easy
- Less than 15 mins
-
Socket set, Wrench set
The hardest part was moving the side-by-side refigerator out from the wall. After accessing the back of the unit ,it was a matter of removing a few screws to remove the back plate. The valve was attached with one screw that held it to the unit. After disconnecting the electrical and water lines the valve was out. Replaced the new valve in
... Read more
reverse order. Everything works great.
Read less
Was this helpful?
Thank you for voting!
Ice Maker Timing was off
11 of 11 people
found this instruction helpful.
-
Mark from Antelope, CA
- Easy
- Less than 15 mins
-
Screw drivers
The Ice maker would not run through a cycle. It would fill with water and produce ice but would need a little help by pressing up on the ejector to run through its cycle. Otherwise, it would not bring the ice to the holding bend. Sometimes the water would not fill. The icemaker was making ice it just was not letting the ice maker run
... Read more
through its cycle so I figured it had to be the circuit board. I bought the circut board which was easy to install.
1) Turn off water line and unplug power.
2) Pop off front panel plate at ice cube select switch area.
3) Unscrew 4 screws that holds control panel housing in place.
4) Remove panel assembly by disconnecting two different wiring plugs.
5) Unscrew 2 screws that allows access to control circuit board at end cap.
6) Remove circuit board by sliding it out of the assembly housing.
7) Install new circuit control board in assemble housing and screw on end cap retainer.
8) Attach two electrical wiring plugs.
9) Install control board assemble housing into frig opening and secure with 4 screws.
10) Install front panel plate (pops on).
11) Plug in power and turn on water line.
1) Turn off water line and unplug power.
2) Pop off front panel plate at ice cube select switch area.
3) Unscrew 4 screws that holds control panel housing in place.
4) Remove panel assembly by disconnecting two different wiring plugs.
5) Unscrew 2 screws that allows access to control circuit board at end cap.
6) Remove circuit board by sliding it out of the assembly housing.
7) Install new circuit control board in assemble housing and screw on end cap retainer.
8) Attach two electrical wiring plugs.
9) Install control board assemble housing into frig opening and secure with 4 screws.
10) Install front panel plate (pops on).
11) Plug in power and turn on water line.
Read less
Was this helpful?
Thank you for voting!
slow water flow in dispenser
14 of 21 people
found this instruction helpful.
-
dwight from phoenix, AZ
- Really Easy
- Less than 15 mins
opened refrigerator door located water filter location in right back corner unscrewd 1/2 turn and out it comes without shutting off water it is a snap to do by anyone and shipment was really quick thanks. People do not call a service tech for something this simple even a child tall enough can do it.
Was this helpful?
Thank you for voting!
Fridge wouldn't start
12 of 15 people
found this instruction helpful.
-
Patrick from Medford, NY
- Really Easy
- 15 - 30 mins
-
Nutdriver
Removed cowling unpluged timer and pluged in new one.
Great Service, got part in one day
Great Service, got part in one day
Was this helpful?
Thank you for voting!
Water was leaking from rear of refirgerator
18 of 33 people
found this instruction helpful.
-
James from Midland, MI
- Easy
- 15 - 30 mins
-
Wrench set
Unplugged refrigerator.
Disconnected inlet water line.
Disconnected outlet from leaking valve.
Unplugged electrical connections.
Reversed with the new part.
Plugged it back and there were no more leaks.
Disconnected inlet water line.
Disconnected outlet from leaking valve.
Unplugged electrical connections.
Reversed with the new part.
Plugged it back and there were no more leaks.
Was this helpful?
Thank you for voting!
Flapper was stuck open. Old and warped.
16 of 27 people
found this instruction helpful.
-
James from Virginia Beach, VA
- Easy
- 15 - 30 mins
-
Screw drivers
Replaced flapper
Was this helpful?
Thank you for voting!
Light in the refrigerator went out
13 of 18 people
found this instruction helpful.
-
Paulette B. from Santa Ana, CA
- Really Easy
- 15 - 30 mins
After I bought what I thought I needed for the repair. I asked a friend to come over and look at it. He changed the
the light socket and put the same light bulb in and it works great. I am returning the light switch but decided to keep the light bulb.
Getting on the internet was so easy. This was really very simple. ... Read more Thank you for making what I thought would be a big ordeal into something very simple.
Paulette Johnson
the light socket and put the same light bulb in and it works great. I am returning the light switch but decided to keep the light bulb.
Getting on the internet was so easy. This was really very simple. ... Read more Thank you for making what I thought would be a big ordeal into something very simple.
Paulette Johnson
Read less
Was this helpful?
Thank you for voting!
Moving the refrigerator into my new (very old) house we had to remove the doors which resulted in a crimped hose and union
16 of 28 people
found this instruction helpful.
-
Laura from Manchester, NH
- Really Easy
- 15 - 30 mins
-
Screw drivers
Remove lower front panel, disconnect damaged union from water hose under freezer door, replace with new union, tighten and reattach front panel. No more water coming from under the unit. Ice maker and dispenser features returned to working order!
Was this helpful?
Thank you for voting!
Interior light needed replaced
22 of 46 people
found this instruction helpful.
-
Leo from TWIN FALLS, ID
- Really Easy
- Less than 15 mins
-
Nutdriver
Unplugged the appliance for safety. Removed two 1/4" screws that held the assembly in place. Carefully removed the wire guard that retains the glass shield. Unscrewed old light bulb and replaced with new part. Reversed the steps after cleaning glass cover.
Was this helpful?
Thank you for voting!
Defrost Thermostat quit working
11 of 13 people
found this instruction helpful.
-
Jimmy from Palmer, TN
- Really Easy
- Less than 15 mins
-
Screw drivers
Take the back panel off inside of freezer side. Cut the wires off old Defrost Thermostat and strip the ends. Attach the wires of the new one and tighten with wire nuts. Put back panel back on.
Was this helpful?
Thank you for voting!
Refridgerator Freezer stoped making ice
17 of 31 people
found this instruction helpful.
-
Marion from Palm Coast, FL
- Easy
- 30 - 60 mins
-
Screw drivers
Turned off power, removed cover from Ice maker, checked resistance across thermostat for zero (read open), all other switches read proper value (when activated). Ordered and received thermostat. Removed Ice Maker from freezer, removed two screws holding ice tray to Control Assembly. Removed Thermostat and replaced with new one. Applied Si
... Read more
licone Sealant to face of Thermostat for adhesion to ice tray when assembled. Remounted Ice Tray to Control Assembly and remounted in freezer. Works Great...