crushed ice feature inoperative, broken pieces in water dispensed.
Found broken pieces of deflector in delivered ice. Removed dispenser, carefully disassembled it, marking fasteners, sprimgs, and levers. Local repaimen say no replacement part available, must replace entire ice maker @ $350. Found exact part in your online reference, ordered at price of $3.76, part arrived two days later--perfect fit, exactly same as original. Reassembled, and it works exactly like new. Family very happy. Good job!!!!!
Parts Used:
Ice Dispenser Deflector
  • Jim from Jacksonville, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
6 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer stayed cold but Fridge got warm every 3 weeks
Unplug the fridge, then:
1) Remove food and shelves from freezer
2) Remove rear panel from inside freezer (panel that covers the evaporator coils)
3)Stare at all the ice covering the coils for 10 seconds!
4) Plug the drain hole in the bottom left side of the freezer (cork or plug made from rolled up paper towel), and place a big towel in the bottom of the freezer compartment to absorb the melting ice
5) Plug in a table fan and leave it blowing into the freezer compartment, at the iced-over coils. Come back in 30 minutes.
6) Ice should be all melted. Place the wet towel in a bucket.
7) Remove the little clip attached to the green wire from the top of the panel., and then remove the two top screws on either side of the panel covering the coils. Take out the panel.
8) Removed the two screws that hold the heater element in place at the bottom of the coils. Pull the element out about 3 inches and disconnected the two wires.
9) Connect the wires to the new heater element, and screw it back into place. Put panel back, shelves in, turn fridge on. Fixed

I ordered the defrost heater and replaced that, also ordered the defrost thermostat but the old one looked fine so I did not replace that. Fridge and freezer have been working great, no more icing problems.

Thank You PartSelect!
Parts Used:
Defrost Heater Harness Kit
  • Mike from Seaford, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
slide rail broke causing shelf to fall
repair was simple removed glass shelf and removed the two screws holding rail in place. I was really amazed at the quick service that I had receiced, I ordered two of the same part and they had the instructions to send back the additional part in my email the next day. Thanks for your help.
Parts Used:
Drawer Slide Rail - Left Side
  • Mark from Albuquerque, NM
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice chute frosted up
Procedure for Replacing the Ice Chute Plate
1. Turn off the power.
2. Snap off the outside trim ring. Use a plastic screwdriver to avoid scratching the cabinet.
3. Locate the three small holes below the control panel facing, just above ice chute. The center hole is not used. With a small, blunt, object (wire – blunted nail) that is slightly smaller than the holes, push up rather firmly up through the outer holes to release front control panel.
4. Remove the three wire connectors from printed circuit board. Firmly pull/pry them straight out of retaining clip. Use caution: Excessive force will break clips.
5. Release the secondary panel by removing four screws (one in each corner).
6. Remove the flap assembly.
7. Clean all accessible areas with 1/10 bleach water to sanitize. Rinse the cleaned area with clear water and thoroughly dry everything before re-assembling the panel.
8. Install the new flap assembly.
9. Re-installed everything in the reverse order and check the functionality.
10. Order a spare ice chute flapper to be ready for the next event.
Parts Used:
Dispenser Door Assembly or Flapper
  • Phillip from Springfield, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
6 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
no Ice
Turned off The water supply. Removed the back panel corner(nut driver). Removed valve (nut driver) and water supply inlet line. Cut the old outlet lines at the valve (new lines are push in) disconnected electrical lines, Reinstalled inlet line and electrical lines. Reinstalled valve and back panel. Turned on the water. Ice maker filled with water and a short time later I had ice. Easy job.
Parts Used:
Dual Inlet Water Valve
  • George from Brandywine, MD
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Maker would not fill.
Was concerned that new icemaker was quite a bit different than the one we were replacing. Called GE to confirm it was correct.

Went ahead and installed the unit, using the supplied electric cable adapter.

A little difficult to deal with the extra cable, but everything worked OK and it's making ice normally.
Parts Used:
Ice Maker
  • Charles from Keller, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
door wouldn't close
First I propped up the door. Then I removed the 2 screws that hold the hinge on. AT this point you do need someone else because the door swings loose. I attached the new bracket and lowered the door. It went verey smooth. I ordered the new bracket after reading the installation stories from others who just repaced the plastic pieces. Its worth the extra money to just put on a new bracket
Parts Used:
Bottom Hinge Assembly
  • Linda from Manorville, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Socket set
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerat
rerfrigator side not cooling After determinating that the defrost timer was running I turned it to defrost and watched tosee if frost started to melt. When it didn't I checked the heater with ohmeter, checked OK, so the only other component in the defrost system is the thermostat. Then just a matter of cutting and splicing wires and snapping the new thermost in place
Parts Used:
Defrost Thermostat
  • Charles from Rose Bud, AR
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Wrench set
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The vegetable pan was broken from closing the door on it too hard when still open
I just slide the new one in place, using exsisting sliders. I had to remove the old grab handle from old pan and snap it into place on new pan.
Parts Used:
Upper Vegetable Pan
  • John from Randle, WA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Hinge Cam Riser broke - door wouldn't self-close
I removed all of the items in the refrigerator door. I then removed the top hinge cover with a Philips screwdriver, and removed the two machine screws holding the top hinge using a socket wrench. This allowed me to lift the door off the bottom hinge pins and set the door on its side. I removed the two screws holding on the broken bottom hinge cam riser block and replace it with the new one. After tighening it back with a socket wrench, I tried to put the door back in place. I asked my wife to hold the door steady while I lay on the floor to guide the door downward over the bottom hinge pin. I then replaced the top hinge screws and checked the door. It still didn't close on its own! I realized I had to loosen the top hinge screws and adjust the door so that it stands more vertically (evening the gap with the freezer door). With this adjustment, the door closes fine.
Parts Used:
Hinge Cam Riser
  • Richard from Los Altos, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
evaporator coils iced up causing no cooling in freezer or fridge.
First I disconnected the Power from the unit. Pulled out the freezer drawers and the ice machine used a 1/4 inch nut driver and removed the sheet metal from the back of the freezer exposing the evaporator coils. I defrosted the coils. Then I removed the two screws holding the defrost heater braket assembly and removed the two electrical connections from it. I then installed the new heater put everything back together(reverse of installation)and it works like a brand new fridge and freezer.
Parts Used:
Defrost Heater Harness Kit
  • Kenneth from Sweet Home, OR
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The Icemaker failed to make ice
I pulled the refrigerator away from the wall and turned off the water to the refrigerator and unplugged it from the wall. After removing the icebucket from the freezer I located the mounting screws, loosened them, unplugged the electrical connection below the icemaker and carefully removed it from the freezer. I unpacked the replacement icemaker, matched it against the original and attached the electrical connection adapter. Using the slots provided on the new icemaker I placed it over the mounting screws after aligning the water inlet pipe properly. I tightened the mounting screws while maintaining the icemaker in a level position. I plugged in the electrical connector. Then I replaced the icebucket, plugged in the refigerator back into the 110VAC outlet, turned on the water and repositioned the refrigerator in it's normal position.
Parts Used:
Ice Maker
  • Dean from Folsom, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
8 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
no ice made
Performed self test.turned off ice maker switch four 5 minutes.Then turn on switch,within 10 seconds,pushed ice paddle 3 times,with 1 second in between each push.Push all the way back and release. Ice maker should cycle and squirt water. My ice maker did neither.I unplugged cord from fridge.So i replaced the ice maker.After a couple of screws had ice again !
Parts Used:
Ice Maker
  • Robert from San Marcos, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Solenoid was hanging creating an awful noise when dispensing ice
Unplugged the refrigerator. Removed the panel to the ice/water dispenser. Removed the cover that displays ice type/water and light. Removed the 4 screws holding the cover. Unplugged the wiring harness to the cover which allowed easy access to the two electrical connections to the solenoid.
Removed the three bottem screws holding the solenoid in place. Loosened the top screw ( do not remove completely) and the solenoid slide down. Removed the solenoid arm that hangs on door latch.
Install hang solenoid arm on door latch; slide solenoid up under top screw. Install bottom 3 screws to hold solenoid in place then tighten top screw. Reattach electrical lines to solenoid then plug wiring harness back into cover. Install 4 screws holding panel in place. Re-install two remaining covers.
Parts Used:
Dispenser Door Solenoid Kit
  • Christopher from Acworth, GA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice dispensing door would not function
I replaced the control board and the solenoid. This was very simple and easy to do. Make sure the power is disconneted before starting. I then removed the accuator pad and holder. Removed the face plate by simply pulling on it. I then removed the four screws holding the control board unit. I unplugged the unite by pulling the block connector on the left side. I then marked on paper the connections to the solenoid and unplugged it. I removed the three screws holding the solenoid the removed it. When installing the new solenoid make certain the rod to the dispenser is put into the solenoid plunger. Then replace the three screws and plug the wires back in using the connections written down on paper. I then removed the two philips screws on the control unit hold down bracket in order to remove the controll board. After removing the screws and the hold down bracket, I pulled the old board out and put the new one in. I then reinstalled the unit, faceplate, and accuator pad. I then turned the power back on and tested it. Worked like new, saving a lot of money...
Parts Used:
Dispenser Door Solenoid Kit Actuator Pad
  • Robert from Philadelphia, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
4 of 5 people found this instruction helpful.