Broken water line near solonoid to feed drinking water
20 of 29 people found this instruction helpful.
  • Gregory from Yucca Valley, CA
  • Really Easy
  • Less than 15 mins
  • Nutdriver
bought an push in, in line connector and a new 5/16 plastic hose. I just replaces 2 feet of plastic hose from the selonid up an splices the hose using the connector. Worked perfect.
Was this helpful?
Thank you for voting!
Refrigerator to warm freezer ok
16 of 18 people found this instruction helpful.
  • Christopher from Madison Heights, MI
  • Easy
  • Less than 15 mins
  • Nutdriver
The comments from customers experiences gave me the confidence that the defrost timer was the problem since the compressor was still working and it went just as they all said, four 1/4' hex head screws and I had access to the old timer, unplugged the old ,plugged in the new and put the four screws back in. Nothing happened so after a whil e I looked a bit harder at the accessable part of the timer after intallation and saw what looked like a dial. I turned the dialclockwise and immediatly the compressor turned on. I have not found any information as to how much or little to turn this dial which obviously is an adjustable cycle setting so I just turned it all the way, so far everything is working alright.
Was this helpful?
Thank you for voting!
Compressor overheating - Fridge not Cooling
16 of 19 people found this instruction helpful.
  • CHRIS from LAGUNA NIGUEL, CA
  • Difficult
  • 1- 2 hours
  • Nutdriver, Pliers, Screw drivers
Condensor Fan not turning. I thought it would be an easy fix. I thought I could pull off the shroud and fan assy - no joy. Too many copper pipes and lots of tubing in the way. It took 90 minutes to remove and 30 minutes to install. The BIG hint here is to loosen the shoud, pull it back as far as you can and then remove the nut that holds the fan blade in place. THEN you can remove the motor. Get the new motor back into the shroud, get the blade back on and then tighten the shroud back up.
Was this helpful?
Thank you for voting!
Flapper not sealing. Frost buildup on inside of freezer door
15 of 17 people found this instruction helpful.
  • D from ZELLWOOD, FL
  • Easy
  • 15 - 30 mins
  • Screw drivers
Followed previous instructions from a previous post. Inserted small screwdriver in the 2 outer holes up under the face plate to remove it then removed 4 screws holding the inner assembly which allowed access to the flapper assembly. Replaced it and reassembled everything. Problem solved
Was this helpful?
Thank you for voting!
water line leaking behind refigerator
14 of 15 people found this instruction helpful.
  • Michael from Merrimac, MA
  • Easy
  • 15 - 30 mins
  • Pliers
Plastic water line gets brittle from compersor heat over time and eventually brakes. I tried to fix with 5/16 line from a locel hardware store but outter diameter was slightly smaller so connection to valve leaked. This OEM part fit perfect. I cut the line beyond the brake and connected it with the tube union part, Easy fix. Everyt hing works fine with no leaks
Was this helpful?
Thank you for voting!
Water Leak From The Ice Make - Water All Over The Frig
14 of 15 people found this instruction helpful.
  • David T from Irvine, CA
  • Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers, Wrench (Adjustable)
Replace the old water valve (wr57x11) with the new one (wr57x10051: make sure you unplug the 110 ac power . And close the water come to the refrig. First 1. Open the paper panel on the back with screw driver. 2 Use a small adj. Wrench to take the old valve of. 3. Label the connector and its terminals in a proper number to ident ify their connector. 4. Unscrew 2 water hoses - one to the drinking one to the ice maker. They are in diff. Sizes - make sure to mark where the hoses connected in case you need to use it again. 5. Cut of the thread section on the hose end - you do not need thread any more on the new water valve. 6. Make sure the new valve is in the same position as the old one. Then plug the water hoses to the valve - and connector terminals. There are 2 new terminal adapter in your new package. These new adapter will be fit to the old hardness for connecting to the new valve. 7. Secure the valve onto the refig frame then plug in the water hose to make sure no leak at the valve. The new valve has new type of self-lock plug ( not thread ) to the 2 water hoses. Make sure to press hard so the hoses are fit in to these new water . Valves. Turn on the water and power on on the refrig. That's all. Very simple save $300 for hiring the service man. Good luck to all.
Was this helpful?
Thank you for voting!
My 13 yr grandson assisted me on this
15 of 18 people found this instruction helpful.
  • Sherry from Auburn Hills, MI
  • Really Easy
  • Less than 15 mins
We couldn't get the other connector loose from one end of the tubing so he said just cut it and so we did and attached the connector. I now have water again in my fridge and took the sticky note down "don't use the water" as it had leaked for a year...... Thanks!
Was this helpful?
Thank you for voting!
Water and Ice acuator had a hole in it. Need to be replaced.
15 of 18 people found this instruction helpful.
  • Lowell H from Gilbert, AZ
  • Really Easy
  • Less than 15 mins
Used my fingers and pulled the old one our and pressec the new one in all in about 30 seconds. Saved at least a $60 service call.
Was this helpful?
Thank you for voting!
Door hinge cam crumbled
14 of 16 people found this instruction helpful.
  • Ralph from Portland, OR
  • Really Easy
  • 30 - 60 mins
  • Nutdriver
Simple job, empty the door shelves, remove top hinge, lift door off bottom hinge, remove bottom hing. The reassembly is the reverse, with a little cleaning along the way and a little white lithium grease on the hinge pins and cams.
Was this helpful?
Thank you for voting!
ice maker not making ice
16 of 22 people found this instruction helpful.
  • Cristina from Los Angeles, CA
  • Really Easy
  • Less than 15 mins
  • Screw drivers
just unscrewed the 3 screws, attached the rounded plug that came with the unit and screwed back only 2 screws. ice magic in about a couple of hours
Was this helpful?
Thank you for voting!
freezer freezing, refrig warm
15 of 20 people found this instruction helpful.
  • Tom from Schofield, WI
  • Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
pretty straight forward,removed threw screws to replace the defrost timer and reverse the procedure. To replace the defrost unit 1st removed metal back plate in freezer. Step 2 defrost freezer. step 3 remove four screws that hold defrost elements in freezer compartment. Step 4 install new defrost elements and secure back in place with fou r screws. step 5 optional read old defrost heaters with ohm meter to confirm the defective part. step 6 plug back in frig and enjoy a cool brewski ahhhhh. By the way only one defrost element was bad (open) but as mentioned in literature which came with new derost elements I replaced both of them. Thanks again for all the help on this, saved me $2000 on a new frig.
Was this helpful?
Thank you for voting!
the left drawer slide rail was broken from years of use.
16 of 23 people found this instruction helpful.
  • Carlton from Chino, CA
  • Really Easy
  • Less than 15 mins
  • Screw drivers
First I removed the vegetable drawer and glass shelf. I matched up the 'new' drawer slide rail next to the broken slide.
I then used a phillips head screwdriver to remove the 2 screws that held the slide in place.
After removing the broken slide rail, I installed the new rail, replaced the vegetable drawer and glass shelf. N ew item worked like a charm.
The drawer slide arrived really quick after my order was placed. Approx. 2 days after ordering the part, it was on my front door step.
Was this helpful?
Thank you for voting!
Switch failed on which kept the refrigerator warm due to heat generatered by light bulbs.
19 of 33 people found this instruction helpful.
  • Terry from Simi Valley, CA
  • Really Easy
  • Less than 15 mins
  • Pliers, Screw drivers
While the switch did last for 9 years, the design is poor due to the failure mode. The failure should be to fail off or not able to turn on the lights which would be inconvenient but would not warm the refrigerator contents. Arcing at the contacts eventually caused the switch to "weld" closed. It is not obvious that this is occurring s o it took some time to recognize why the temp inside the ref was high while the freezer was OK. Replacing the switch was easy once it was recognized as the problem. All that was required to replace the switch was to remove the screws holding a fiber cover and then pulling off the aluminum cap which covered the switches. Unplug the switch an squeeze the keeper on the switch to release it and pull down. Pop the replacement switch in place and plug the wires harness back in. All in all it took much less time to replace than it has to write this up. T Pope
Was this helpful?
Thank you for voting!
icemaker developed a leak and froze over
18 of 30 people found this instruction helpful.
  • debbie from chino hills, CA
  • Easy
  • 15 - 30 mins
My husband did the repair, and even though our refrigerator is roughly 20+ years old, he was able to adapt it to work in all the right spots and we now have ice cubes! I'm very happy we did not have to spend $2000 on a comparable refrigerator.
Was this helpful?
Thank you for voting!
Noisey Motor, Bearings Out, Dying
12 of 13 people found this instruction helpful.
  • PERRY from VANDERBILT, MI
  • Easy
  • More than 2 hours
  • Nutdriver, Wrench set
Remove back cover, exposing fan motor. Turn off power, remove nut on fan blades. Remove fan carefully, do not bend. Unhook wiring harness. Remove three screws that hold the motor on the back frame. Remove old motor, install new. Carefully, reinstall fan blades, hook up wiring, and your ready for tryout. Also do some cleaning whil e your there. Clean old fan blades with hot soapy water or contact cleaner. Everything runs better clean!
Was this helpful?
Thank you for voting!
All Instructions for the 36358251893