Models > 36358077896 > Instructions

36358077896 Kenmore Refrigerator - Instructions

All Instructions for the 36358077896
31 - 45 of 644
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Both Slides Were Broken
I removed the shelf, unscrewed the slide rails and replaced them with new ones. I replaced the shelf, put the food back in and I was done. Thanks, john bowers
Parts Used:
Drawer Slide Rail - Right Side Drawer Slide Rail - Left Side
  • John from Charlotte, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
23 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Replace ice maker
New ice maker only used 2 screws and the old one had 3. This was no problem. The old ice maker had already been removed. Just loosen the 3 screws and unplug the cord to ice maker. Only problem with ice maker was with the cord, which I had to use the supplied adapter. It was too long and in the way when reinstalling the ice bin. The ice bin had a small notch area on the bottom left. I used a plastic tie to bundle the cord into the notch. Carefully placed ice bin and no problem. The first part I received was damaged and was replaced 2 days later by a brand new part. Customer service charged for the replacement part but said they would credit my charge card within 2 to 3 weeks for the damaged part. Its been a week and if they follow thru like the said I woild give Part Select 5 Stars for service and Parts.
Parts Used:
Ice Maker
  • Gary from Glendale, AZ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
21 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrig. Side not cooling enough
Replaced several things: evaporator fan motor, defrost heater element & defrost timer. The motor was the key problem but did the other repairs because they are common failures and are easy to replace and are not that expensive. Changing the motor was tedious because of tight access to it. Took about 2 hrs for me. Fan is working properly but not have a problem with water to ice maker not shutting off. I'm researching that problem. (I replace the water valve 2 hrs ago. That was a simple task - took 15 mins.)
Parts Used:
Evaporator Fan Motor
  • William from Moorestown, NJ
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Screw drivers
22 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker would not make ice..
1) I removed the icemaker and placed on work table.
2) I pried the front plastic cover from the control box to expose the front base.
3) I removed the three mounting screws from the base (it is not necessary to remove the screw in the plastic gear) and removed the front base. This exposed the back base
4) Using an ohmmeter, I was able to isolate a bad contact on one of the three microswitches in the control box (the one that was mounted to the back base). Replacing this microswitch solved the problem.
Parts Used:
Icemaker Switch
  • James from Mebane, NC
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
19 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Frig would stop working every so often. Lots of food got spoiled.
Got part overnight. Unscrewed cover plate at top of regerator compartment, disconnected old part, connected new part. Screwed back plate. Voila!

I saved a bunch of money!
Parts Used:
Defrost Timer
  • Rene from Bronx, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
17 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Stripper on the icemaker broke into pieces.
Remove the two nuts holding the top of the unit to the side of the freezer using a 1/4 in nutdriver. Pull the unit out and unplug it from the back of the freezer. Remove all pieces of the broken stripper. The replacement part fits onto a peg on the back of the icemaker and into a slot. Bend into place and slide into position.
Parts Used:
Ice Maker
  • Tracy from Yuba City, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
18 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken water line near solonoid to feed drinking water
bought an push in, in line connector and a new 5/16 plastic hose. I just replaces 2 feet of plastic hose from the selonid up an splices the hose using the connector. Worked perfect.
Parts Used:
Plastic Tubing - 5/16 Inch Union Connector - 5/16 Inch to 5/16 Inch
  • Gregory from Yucca Valley, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
20 of 29 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator to warm freezer ok
The comments from customers experiences gave me the confidence that the defrost timer was the problem since the compressor was still working and it went just as they all said, four 1/4' hex head screws and I had access to the old timer, unplugged the old ,plugged in the new and put the four screws back in. Nothing happened so after a while I looked a bit harder at the accessable part of the timer after intallation and saw what looked like a dial. I turned the dialclockwise and immediatly the compressor turned on. I have not found any information as to how much or little to turn this dial which obviously is an adjustable cycle setting so I just turned it all the way, so far everything is working alright.
Parts Used:
Defrost Timer
  • Christopher from Madison Heights, MI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
16 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Compressor overheating - Fridge not Cooling
Condensor Fan not turning. I thought it would be an easy fix. I thought I could pull off the shroud and fan assy - no joy. Too many copper pipes and lots of tubing in the way. It took 90 minutes to remove and 30 minutes to install. The BIG hint here is to loosen the shoud, pull it back as far as you can and then remove the nut that holds the fan blade in place. THEN you can remove the motor. Get the new motor back into the shroud, get the blade back on and then tighten the shroud back up.
Parts Used:
Condenser Fan Motor - 115V
  • CHRIS from LAGUNA NIGUEL, CA
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers
16 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Flapper not sealing. Frost buildup on inside of freezer door
Followed previous instructions from a previous post. Inserted small screwdriver in the 2 outer holes up under the face plate to remove it then removed 4 screws holding the inner assembly which allowed access to the flapper assembly. Replaced it and reassembled everything. Problem solved
Parts Used:
Dispenser Door Assembly or Flapper
  • D from ZELLWOOD, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
15 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
My 13 yr grandson assisted me on this
We couldn't get the other connector loose from one end of the tubing so he said just cut it and so we did and attached the connector. I now have water again in my fridge and took the sticky note down "don't use the water" as it had leaked for a year...... Thanks!
Parts Used:
Union Connector - 5/16 Inch to 5/16 Inch
  • Sherry from Auburn Hills, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
15 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer freezing up
Unplug refrigerator,remove the freezer bulb, trays and rear cover to expose coils and heating element/defroster, The telltale sign its bad was it looked like an old flashbulb/burned, the old one was open, melt enough ice to remove and replace the defrost element(2 screws 2 wires) and reinstall components, reconnect power, thats it.
Parts Used:
Defrost Heater and Bracket Assembly
  • richard from cleburne, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
16 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water line leaking behind refigerator
Plastic water line gets brittle from compersor heat over time and eventually brakes. I tried to fix with 5/16 line from a locel hardware store but outter diameter was slightly smaller so connection to valve leaked. This OEM part fit perfect. I cut the line beyond the brake and connected it with the tube union part, Easy fix. Everything works fine with no leaks
Parts Used:
Union Connector - 5/16 Inch to 5/16 Inch Plastic Tubing - 5/16 Inch
  • Michael from Merrimac, MA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers
14 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water and Ice acuator had a hole in it. Need to be replaced.
Used my fingers and pulled the old one our and pressec the new one in all in about 30 seconds. Saved at least a $60 service call.
Parts Used:
Actuator Pad
  • Lowell H from Gilbert, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
15 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer Cold Refrigerator warm
The defrost heater failed. The coils frosted completely over so no airflow to the fridge. Step 1. Empty the freezer. Ice maker and top shelf can stay. Remove power, pull plug or open breaker. Step 2. Remove shelves and bottom food drawer. Step 3. Remove bottom food drawer rails. 2 phillips screws on each side. Step 4. Remove back panel, 2 screws at the top. Work panel out. Note there may be a green ground wire hook on it at the top. This will expose the heater and the cooling coils. The heater is at the bottom of the cooling coils and is the width of the coils. Step 5. There will be 2 wires, one on each end, and two phillips screws holding it in. Wires pull straight out. Note which way the heater is installed and remove the 2 screws. Step 6. Assemble in reverse order. Be very careful with the heater. It is in a glass tube and is very easy to break.
Parts Used:
Defrost Heater and Bracket Assembly
  • Steve from DOWS, IA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
13 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 36358077896
31 - 45 of 644