Ice maker stopped making ice
2 of 3 people found this instruction helpful.
  • Robert from Wyckoff, NJ
  • Easy
  • 15 - 30 mins
  • Screw drivers
I had made a dry run at the repair after watching the instructional film provided by part select and it seemed easy enough.
The only problem was that i needed to use the electrical cord extender (provided) to adapt to my plug type. That presented a problm because it needed to be tucked up out of the way to allow the ice bin to clear . Just needed to be creative in how you wrapped the cord behind the ice maker unit before snugging the attachment screws.
Cranking out ice like crazy.
Was this helpful?
Thank you for voting!
water dispenser/ice maker wouldn't work
2 of 3 people found this instruction helpful.
  • Thomas from Grapevine, TX
  • Easy
  • 15 - 30 mins
  • Screw drivers, Wrench (Adjustable)
Unplugged refrigerator and turned off water valve at wall. Removed the entire back, lower cardboard panel (turns out I didn't have to do this...could have just removed the screws from the right side and folded the cardboard along a perforated line designed for that purpose). Removed screw holding water control valve to back of refrigerat or. Took new control valve, and slipped on adaptors for electrical connectors (in bag) to the two smaller of the four electrical prongs). Removed electrical sockets from old connector and placed them over appropriate prongs on new connector. Unscrewed the two old water out lines, cut the old fittings off and slipped the lines snugly into the new outlet valve (new valve had slip on connectors not requiring lines to be screwed in). Keep straight which line goes to which outlet port! Then removed water line going into old fitting and screwed it on to new valve inlet fitting (after removing black plastic protective cap). Turned wall water valve on, checked for leaks (none), and plugged refrigerator back in. Water restored to both icemaker and water dispenser!

By the way, the first valve came damaged, but one phone call and the people at Part Select promptly sent out a replacement which I had the very next day (and this was two days before Christmas!). Great job!
Was this helpful?
Thank you for voting!
After the ice dumped, the tray would overfull and run over into the freezer
2 of 4 people found this instruction helpful.
  • Henderson from Holladay, TN
  • Easy
  • 15 - 30 mins
  • Nutdriver, Pliers
The operation is very simple on this valve. I disconnected the water lines and wires.
Then two I removed the two screws attaching
valve to the ref.box.
The reinstall is just the opposite from removal.
Was this helpful?
Thank you for voting!
Watched video on flapper assembly replacement looked real ready. Video failed to mention ice dispenser trim was glued in place . Had to buy real small paint scrapper that would fit in dispenser outlet to free inside edge of trim piece. Once I got it all loose job went very easy.
1 person found this instruction helpful.
  • Dennis from Rogers, AR
  • Difficult
  • 30 - 60 mins
Use small putty knife to cut internal sealant on ice maker door trim piece. Then you can easily remove it.
Was this helpful?
Thank you for voting!
No water supply to ice maker
1 person found this instruction helpful.
  • James from LOS ALAMITOS, CA
  • A Bit Difficult
  • 30 - 60 mins
  • Pliers, Screw drivers, Socket set, Wrench (Adjustable)
Received the first water valve with very poor included instructions. Watched the suggested instructional YouTube for my part installation which was very well done except my new part was not identical to my old part or the one in the YouTube. A translucent plastic housing on the part obstructed the installation so I needed to trim part of it away with a tin shear before attaching the part to the refrig. The waterline attachments were slip fit rather than what my old part had with compression nuts. I replaced all the plastic water lines using the slip fittings, turned the water back on and- all fittings leaked. Undid the fittings, trimmed the water lines and reattached- still leaked. So I contacted customer service who sent out a new part and followed the above procedure and everything went quickly with no leaks. I suggest you replace the two plastic water lines ( you will need to buy two slip fittings and two diameter lines) these are available at Home Depot. There is also a YouTube for this and it is a must see. My main supply line to the refrigerator is copper tubing. I trimmed the end of the tubing, filed it smoot, steelwooled the surface and installed a new brass compression ring befor reactching to the valve. Note, because of the first leaks, I found it easier to make all my connections including the electrical, plug the refrigerator back in and active the ice maker and water dispenser before reaching the valve the the frig back. Good luck.
Was this helpful?
Thank you for voting!
Remove front cover
1 person found this instruction helpful.
  • Philip from S BURLINGTON, VT
  • A Bit Difficult
  • 30 - 60 mins
  • Screw drivers
Remove front cover did not remove wires remove ice and water unit took off flapper put new one on 5 minutes back together
Was this helpful?
Thank you for voting!
On/off switch stuck in the off position
1 person found this instruction helpful.
  • Dan from HIGHLAND, MD
  • A Bit Difficult
  • 30 - 60 mins
  • Screw drivers
Removed icemaker from freezer,
Removed 3 screws from cover plate, and removed screw securing main gear, removed gear.
Pulled back cover plate to expose switches and mechanism.
Removed screw holding switch to remove switch, and installed new switch.
I should have taken a pic of the cover plate, the interior mechanism a nd the wiring as I went along. It would have saved me 45 minutes in reassembly. Also, as luck would have it, I reversed the wiring on the switch. So off was on, and I had to remove it, switch wires and re-install.
But it works!
Was this helpful?
Thank you for voting!
Had a 'ticking' sound
1 person found this instruction helpful.
  • John from PARKVILLE, MO
  • Easy
  • 30 - 60 mins
  • Socket set
Separately (from a different site) purchased new compressor fan and motor. I purchased the grommets here because the other site listed the grommets as temporarily out of stock. I did watch one of the videos on PartSelect about the grommet replacement. Repair was pretty simple, biggest challenge was getting to the screw on the far side o f the motor. Removed the two screws holding the fan motor into place. Removed motor and blade. Reinstalled with new fan blade, new grommet and new motor.
Was this helpful?
Thank you for voting!
Body case seal gone bad on water valve
1 person found this instruction helpful.
  • David from Columbia, MO
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Wrench (Adjustable)
Easy. First, unplug the fridge.

1)Shut off then disconnect water line.

2)Remove water valve mount screw.

3)Disconnect electrical plugs and snip water lines (square cut lines for new valve).

4)Simply insert and seat water lines into their respective places on the new valve. Using adapters as nee ded, reconnect electrical plugs.

5)Mount valve and reconnect water line.

6)Turn on water supply and check for leaks. Possible leaks: water line or not fully seated lines to the new valve.

7)Restore power and enjoy :o)
Was this helpful?
Thank you for voting!
Warm air enters ice dispenser on door
1 person found this instruction helpful.
  • J Stephen from BETHESDA, MD
  • Really Easy
  • 30 - 60 mins
  • Screw drivers
Replaced flapper. Followed the video. The lamp caused the removable plastic bracket (which supports the control panel and the ice chute) to fuse with the plastic frame in the door. Eventually broke the fused plastic, removed the bracket, and filed the rough broken plastic before reassembly.
Was this helpful?
Thank you for voting!
icemaker quit working when we moved
4 of 10 people found this instruction helpful.
  • Regina from Taylorsville, KY
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
My husband took out the old icemaker in about 5 minutes. The new icemaker was a perfect fit even though the refrigerator was >10yrs old. The only difficult part was the plug extension that was needed so that it would fit into an older appliance. The part was included, it just made the cord about 3 inches longer than it needed to. After wo rking with it for about 20 minutes we were able to fit it on the back side of the icemaker. Now it works great!!
Was this helpful?
Thank you for voting!
Ice maker would not work
1 person found this instruction helpful.
  • Rehn from Austin, TX
  • Easy
  • 15 - 30 mins
  • Screw drivers, Wrench set
Disconnected the power and then the water line. Removed the cardboard shield on back of the refrig. Then removed the faulty solenoid which was held in place by one bolt. Removed the two plastic water hoses and two sets of electrical connectors. I then reversed the process to install the new solenoid. I encountered two challenges. Th e new solenoid had a plastic housing that had to be removed and one set of the electrical connectors required an extension. The extensions were included with the solenoid, but there were no instructions.
Was this helpful?
Thank you for voting!
The water dispenser in the door would drip continuously .
1 person found this instruction helpful.
  • Donald from Pinnacle, NC
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Wrench (Adjustable)
Used the parts diagram from PartSelect.com to locate the valve. Removed the old valve and disconnected inlet water line and the 2 outlet water lines(one for ice maker & one for water dispencer). Reconnected water lines to new valve and positioned it back in place on the refrigerator. Problem solved -no more drip, drip, drip.
Was this helpful?
Thank you for voting!
The water valve was leaking
1 person found this instruction helpful.
  • Joey from Travelers Rest, SC
  • Easy
  • 15 - 30 mins
  • Nutdriver, Pliers
I Took the six screws off the back panel to get to underneath the refridgerator. took the 2 screws out of the bracket thast holds on the water valve took the 2 lines off and then put everything back
Was this helpful?
Thank you for voting!
Leaking Inlet Water Valve
1 person found this instruction helpful.
  • David from Mechanicsville, MD
  • Easy
  • 15 - 30 mins
  • Screw drivers, Wrench set
Very quick and easy repair. Took off cover to access valve using standardr screw driver. After shutting off water supply to valve disconnected copper water supply line. Used a large towel to catch any residual water in line. Removed two water lines on valve use plies if more than hand tight to loosen. Removed screw holding valve in place, removed valve and disconnected wires (be sure power to frig is off least you get a shock. Reverse proceedure to install new valve. new valve has simple push in connections for plastic water lines. Install two electrical adpaters and electric lines. Mount valve with screw, connect copper water line. Turn water back on and check for leaks. Turn power on and check for proper water running at dispenser. Again check for any leaks. No leaks, install cover and you are done.
Was this helpful?
Thank you for voting!
All Instructions for the 36358075891