Frezer frozenin ,no icemaker working
Lets start with the hard part:
Convince wife to get a couple of her girl friends
to go to a movie and see the Reader,after that
visit a cafe or pub (remembered years ago the
English Patient). Drove to get a six pack,removed the back panel-2 min, set a hair drier to position,
had a couple beers , removed the defrost heater unit
1 min. replaced it 1 min. back panel1 min,enjoyed the rest of the afternoon,finished the beer
Killed two birds with one stone
Zoltan L Petho
Parts Used:
Defrost Heater with Thermostat
  • zoltan from New York, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator water dispenser tube (5/16"OD) broken at the back by valve
Tube was too short so I used the union to attach additional tubing to reach the valve at the lower rear of refrigerator
Parts Used:
Union Connector - 5/16 Inch to 5/16 Inch Plastic Tubing - 5/16 Inch
  • Peter from Marietta, GA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Wrench set
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
light not working
I used pliers to pull lightly on the head of the switch, while I inserted a small flat head screw driver into the base of switch and gently worked around the edges to free it from the panel.
Parts Used:
LIGHT SWITCH
  • robert from FRANKLIN SQ, NY
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
7 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator door would not shut
Removed old hinge assembly, bolted on new assembly-door shut like new
Parts Used:
Bottom Hinge Assembly
  • Bobby from SENECA, SC
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Socket set
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Unit had stopped making ice
Ordered the icemaker replacement. unplugged the unit, followed the simple instructions and got it done in less than 30 minutes. It did take a LONG time to start making ice. But it's working now.
Parts Used:
Ice Maker
  • Ron from ORANGE, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refridgerator quit cooling because the defrost element had burned out and the refridgerator coils were totally covered with ice.
I defrosted freezer. Removed cover from back of freezer. Removed screws from element disconected wires. I connected wires to new element installed screws and reinstalled cover.
Parts Used:
Defrost Heater with Thermostat
  • sherry from runaway bay, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
6 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer kept freezing up
Removed the cover for the evaporater coils and let them defrost. Then took the old heating element out by removing two screws on the bottom element and two screws on the top element. Unplugged it and removed it from the unit. Then repeated the reverse of the procedure, installing the new unit, no wires to splice only one plug and four screws.
Parts Used:
Defrost Heater with Thermostat
  • Wesley from Hattiesburg, MS
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
6 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice trap door would not open
1. Unplug refrigerator or flip breaker to kill power to the refrigerator.
2. With hands, gently pull the bottom lip of the 3" X 11" face plate panel above the dispenser head.
3. Remove the 4 screws that are under the removed panel.
4. Tip the assemby down to reveal 2 plugs.
5. Gently pull the 2 plugs to disconnect.
6. Open the assembly to reveal the solenoid.
7. There are 3 screws at the base of the solenoid. The center screw attaches to the green ground wire.
8. Remove the three screws.
9. Observe: The bracket at the top of the solenoid unit tucks behind a 4th screw above the solenoid. You may need to loosen this screw to relesae the solenoid.
10.Unplug the yellow and red connector to the solenoid. It should not be totally free to remove.
11. Put the plunger into the solenoid. Note that the plunger has an opening to insert the white plastic trigger for the trap door. Make sure the trigger is inserted into this opening before reassembling.
12. Plug the yellow and red connector into the new solenoid.
13. Position the new solenoid to match the screw holes. The bracket at the top of the solenoid tucks under the 4th screw. Tighten as necessary.
14. Insert the green ground wire into the middle screw hole at the base of the solenoid and tighten.
15. Insert the two screws to either side of the ground wire and tighten.
16. Gently reconnect the two plugs.
17. Tip the assembly back into place making sure the trap door and hoses are lined up correctly.
18. Replace the 4 screws.
19. Snap the face plate back into place.
20. Turn on the power and give it a try!

I used other instructions provided by customers on the website. They were very useful.

This is the second time we replaced this unit. The first replacement failed within the one-year warranty period. I called customer service and they had a replacement part and refund for the previous part on its way immediately. Excellent service!
Parts Used:
Dispenser Door Solenoid Kit
  • Susan from Polson, MT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
6 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Cold water for door - leaked on floor
Pulled new tubing to the tank and put a union about 8 inches down from tank to new tubing. Great repair. Parts not readily available locally.
Parts Used:
Union Connector - 5/16 Inch to 5/16 Inch Plastic Tubing - 5/16 Inch
  • JOSEPH from SURFSIDE, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice chute frosted up
Procedure for Replacing the Ice Chute Plate
1. Turn off the power.
2. Snap off the outside trim ring. Use a plastic screwdriver to avoid scratching the cabinet.
3. Locate the three small holes below the control panel facing, just above ice chute. The center hole is not used. With a small, blunt, object (wire – blunted nail) that is slightly smaller than the holes, push up rather firmly up through the outer holes to release front control panel.
4. Remove the three wire connectors from printed circuit board. Firmly pull/pry them straight out of retaining clip. Use caution: Excessive force will break clips.
5. Release the secondary panel by removing four screws (one in each corner).
6. Remove the flap assembly.
7. Clean all accessible areas with 1/10 bleach water to sanitize. Rinse the cleaned area with clear water and thoroughly dry everything before re-assembling the panel.
8. Install the new flap assembly.
9. Re-installed everything in the reverse order and check the functionality.
10. Order a spare ice chute flapper to be ready for the next event.
Parts Used:
Dispenser Door Assembly or Flapper
  • Phillip from Springfield, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
6 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The Ice Flapper warped and clogged up the Ice Shoot
I bought a Flapper replacement part from Parts Select. I installed it following their very complete on-line video directions. Their complete and easy to follow directions made my job very easy, and the work was completed without any problems and just as good as if it were done by a professional repair person. I am proud of my work, it couldn't have been done without their video insructions. Also I got delivery of the part within two days of my order. I will alway look for Parts Select any time I need an applicance repaired. Thanks to Parts Select!
Parts Used:
Dispenser Door Assembly or Flapper
  • Ronald from Elkridge, MD
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Drive cup broke due to ice cube jamming it
Remove three screws insert part; manually checked out drive and waited for ice to buildup and it worked like new.
Parts Used:
Ice Dispensing Drive Cup
  • Bruce from Mobile, AL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice being made but would not dispense
Easy repair. Snapped cover off control panel. Removed 4 phillips head screws on control board assembly. Removed (2) connectors from assembly and pulled out defective unit. Installed new control board in reverse order. Everything now working. Very fast and easy repair once you have the part.
Parts Used:
Dispenser Control Board - 2 Slide Switches
  • Robert from Orlando, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Despenser wouldn't dispence ice
All i had to do was pop off the front trim, remove 4 small screws, unplug two plugs and replace the board.

It took me a grand total of 9 minutes to get the job done.

Way cheaper than having a repair man come to the house twice, once to diagnose, and once to replace the board he would have ordered and marked up.
Parts Used:
Dispenser Control Board - 2 Slide Switches
  • Blair from Evanston, WY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken auger in the bucket assembly.
I ordered the wrong part, the ice maker assembly, because your diagram was not marked properly. I returned the part and you credited my account. Thanks. Ordered the new bucket. It worked fine. Now I have ice and crushed Ice whenever I want. Thanks.

p.s. I didnt use any tools, but to satisfy you I select nut driver.
Parts Used:
Ice Maker
  • Chip from Mandeville, LA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
6 of 9 people found this instruction helpful.