Raplaced switch
5 of 9 people found this instruction helpful.
  • Winston A from Brooklyn, NY
  • Really Easy
  • Less than 15 mins
  • Pliers
Repair went well,took about five to ten minutes to disconnect the power from the fridge removed the defective switch installed the new one ,reconnected the power,,,and Let there be light and there was light!
Was this helpful?
Thank you for voting!
Refrig began to trip the GFI circuit in the garage. When plugged into a house interior circuit the lights and fan ran but no cooling in either the freezer or frig.
3 of 3 people found this instruction helpful.
  • riley from CAVE CREEK, AZ
  • Really Easy
  • 15 - 30 mins
  • Pliers, Socket set
First of all I want to thank Michael from Carlisle,PA and this site for publishing Michael's info on the wiring specifics on the new 3 connector Start Relay ( WP2262185 ). The original relay only has 2 connectors The 2 orange wires which are combined to one female connector need to be clipped and separated each to its own connector. Ref er to Michael's blog as to which wire goes to which connector on the Start Relay. I replaced the Run Capacitor, Start Relay and Overload just to be safe. The Start Relay was the actual culprit.Thank you for an excellent website!
Was this helpful?
Thank you for voting!
clicking sound
3 of 3 people found this instruction helpful.
  • Ronald J from TULSA, OK
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
unplugged the power and removed the cardboard back Unplugged the part and power from the side of the compressor Plugged the power and new part back in to the side of the compressor and replaced the clamp Plugged in the power cord to the wall outlet and the refrigerator started to hum Job done Thanks
Was this helpful?
Thank you for voting!
Fill cup broke.
6 of 12 people found this instruction helpful.
  • Aliki from Miami, FL
  • Really Easy
  • Less than 15 mins
Very easy to order from parts select. Took seconds to replace.
Was this helpful?
Thank you for voting!
Ice maker stopped making ice
3 of 3 people found this instruction helpful.
  • Daniel from DAVISBURG, MI
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
Remove 1 screw under ice maker. Gently pull downwards to unhook ice maker. Disconnected 4 pin wire connector. Remove and set aside the cover and wire loop you will need on new ice maker. Reverse the steps to install new maker. Once new ice maker is installed you will have to wait 2-4 hours for ice. There is a thermostat that will need to reach 10 degrees F to operate.
Was this helpful?
Thank you for voting!
door would not self close tightly
3 of 3 people found this instruction helpful.
  • paula from julian, CA
  • Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
Remove two screws from top door hinge.
Remove door from unit
Remove old broken plastic cam 1 screw
Replace new door cam tighten 1 screw
Reinstall door and top hinge screws.
Was this helpful?
Thank you for voting!
lights wouldn't come on/work in refrigerator
4 of 6 people found this instruction helpful.
  • Jane from Albuquerque, NM
  • Easy
  • 15 - 30 mins
  • Pliers, Screw drivers, Socket set
Referencing the info/schematics you have on your website, I unscrewed/unattached top-front panel (carefully), from behind the panel you have to detach the wires (2) from the switch, pushed "in" the switch to remove, put in new switch and attach wires to test BEFORE remounting panel. Tada!! Thank you PartSelect! You saved me at least $80.. .would have been at least $100 to have a repair person come to the house!
Was this helpful?
Thank you for voting!
dual light socket in fridge shorted out
4 of 7 people found this instruction helpful.
  • Kimberly from Blue Springs, MO
  • A Bit Difficult
  • 30 - 60 mins
  • Screw drivers
took old socket out, ordered replacement part, dual socket no longer available. Turn off power to appliance, attach new single light socket, screw light socket and light socket holder back into place. Turned on power and it worked. No instructions included in packet, attached wrong first time, blew fuse, attached socket a different way , and it worked.
Was this helpful?
Thank you for voting!
leaky ice maker - non-stick coating had failed
4 of 7 people found this instruction helpful.
  • Robert from Sunnyvale, CA
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver
replaced the entire ice make - 3 screws and a squeeze -off connector and it's out. Reverse to re-install... except that the fill tube had iced up. To thaw the fill tube: unload freezer section (leave food in fridge, but keep door closed), remove ice maker. Boil water, dip drill bit (dull end) into hot water, swirl around, insert (dull en d) into to fill tube. Depending on how hot you got it, maybe a tablespoon of ice will melt. Repeat many times - fill tube is about 14" long! Do not use anything sharp - you will nick the tube and ice will form causing you to repeat this procedure. Do not try to break the ice - let the heat work. It took me about 30 minutes to thaw the whole thing - it made a nive gasping noise when the final plug opened up. Re-install ice maker.
Was this helpful?
Thank you for voting!
The door made a loud noise on opening and closing.
3 of 4 people found this instruction helpful.
  • Dennis from Kerrville, TX
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
Emptied the door.
Removed the door, top bolts first.
Lifted out the door.
Installed new cam at the bottom.
Set the door back in place.
Bolted the top hinge back on.
Smooth!

The part came quickly and was the right one. You can't imagine how many outfits lose it here. Well done and thanks.
Was this helpful?
Thank you for voting!
The refrigerator stopped running
4 of 7 people found this instruction helpful.
  • Barbara H. from South Hill, VA
  • Easy
  • 1- 2 hours
  • Screw drivers
I was told to order the run capacitor and the technician thought it would repair the refrigerator; but it did not. The appliance technician had to take the run capacitor off and install what he called a "hard start" and the refrigerator is operating right now.
Was this helpful?
Thank you for voting!
Ice maker stopped functioning
3 of 4 people found this instruction helpful.
  • richard from colorado springs, CO
  • A Bit Difficult
  • 1- 2 hours
  • Nutdriver, Screw drivers, Socket set
Part received was what I needed. There was one issue--the 'feed' opening to receive water and direct it into the ice tray was a side feed and what I needed was a back feed. That means I had to do some exchanging of parts to make it work. That exercise took more time that the actual installation.
Was this helpful?
Thank you for voting!
Divider front of fridge hot to touch Condenser fan not working
3 of 4 people found this instruction helpful.
  • John from Holden, MA
  • Easy
  • 15 - 30 mins
  • Nutdriver, Pliers
removed back cover, removed fan motor and replaced with new one. connected new power wires. worked right away
Was this helpful?
Thank you for voting!
Leaking water from bottom
3 of 4 people found this instruction helpful.
  • Jeff from Las Vegas, NV
  • Easy
  • 15 - 30 mins
  • Nutdriver, Pliers
Somebody else wrote a really good description of how to repair, he should write manuals! So, read his..I will just add, most of us have phones that take pictures, so I took pictures and video before I started, so then I could remember how everything went back together.
Was this helpful?
Thank you for voting!
ice maker was over filling and causing water to flow into ice dispenser and freezing it al together
3 of 4 people found this instruction helpful.
  • Michael from Moore, OK
  • Easy
  • 15 - 30 mins
  • Nutdriver
First turned off the water and unplugged the refrigerator and then removed the old ice maker by first removing the side cover plate and then next removed the ice level detector. Remove the screws that hold the ice maker in place and rotating it somewhat soas to gain access to the wires and then unplugged them. Next I had to modify the way the water comes into the new icemaker by adapting a CPVC street ell to fit into the hole on the side and then hook up the water supply. Installation is just the reverse of removal.