Noise from fan
I watch the video on your site and this make iit very easy to do. That repair that tooks me 40 minutes.
Parts Used:
Evaporator Fan Motor Kit - 120V 60Hz
  • Reginald from WEST PALM BCH, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Socket set
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Coils frozen over. Refrigerator not cooling
I cut wires from bad thermostat and removed it . Stripped wires and crimped connectors on new thermostat and wires from old thermostat. Used heat gun to seal sleeves over connectors. Very helpful video from this site Thanks, you will be my go to parts supplier from now on!!!!!!!!!!!!
Parts Used:
Defrost Thermostat
  • Robert from MONTGOMERY, IL
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Socket set
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer worked, refrigerator didn't. Ice build up on coils.
Unplugged refrigerator. Emptied freezer and removed ice maker and cover, need to unplug fan. Defrosted coils with hot water. Cut wires to thermostat as close to it ad possible to leave extra wire in case of an error. Stripped wire in new thermostat and put in shrink plastic then the wire crimp connector joining both light blue wires making sure wires were in before crimping them. Repeated with other dark blue wire. After used the heat gun to shrink the protective white tubing. The only thing i found not satisfying was tge tubing. It was too wide and too small. When i shrunk it did not cover the whole connector and was loose. I had to use a glue gun to cover both ends of each wire connector. Hope this helps other users.
Parts Used:
Defrost Thermostat
  • Salvador from SANTA ANA, CA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken supports on door shelves needed replacement
This is super easy. You just pop the old supports off vertically, pull the bar off of the broken one(s), replace them with the new one(s), then pop the whole thing back onto the door of the fridge by pushing down on both sides.
Parts Used:
Door Shelf Retainer Bar End Cap - Right Side Door Shelf Retainer Bar End Cap - Left Side
  • Ari from ITHACA, NY
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator wasn't getting cold
removed the back panel of the freezer and unplugged the connector for the Motor. Removed the air diffuser, then removed the fan blade. Removed the 2 screws holding the motor to the bracket. Disconnected the old wire harness and installed the new one. Put the fan blade onto the new motor and installed the motor onto the bracket. Put the air diffuser back on, plugged the motor back in and fastened the back panel. Plugged the refrigerator into the outlet and tested, OK!
Parts Used:
Evaporator Fan Motor Kit - 120V 60Hz
  • Brad from STOCKTON, CA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fan motor in the freezer was not working. The freezer was still cool enough to keep the food froozen, but the refrigerator was not keeping the food cool and the liquids were getting warmer than normal.
Very easy process. Watch the YouTube video, it goes step by step for the repair. The part was $33, shipping was $6. Take your time and fix it yourself or pay $500 for a new refrigerator.
Parts Used:
Evaporator Fan Motor Kit - 120V 60Hz
  • Eric from SOUTH HAVEN, MN
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Evaporator was freezing up and was running non stop
I tested the components in the refrigerator defrost function. I used digital multimeter and checked for continuity. Defrost thermostat must 32 degrees or lower.
Parts Used:
Defrost Thermostat
  • James from PHILADELPHIA, PA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light not turning on when door opened
Used a flat head screwdriver to pop out the old switch, removed the contacts and placed on the new switch, popped the switch back in. Done in about 2 minutes.
Parts Used:
Light Switch
  • Michael from TUCSON, AZ
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer worked, no fridge
Removed panel over the motor in the freezer department. Removed screws holding the motor in, unplug wires. Reversed process to install motor.
Parts Used:
Evaporator Fan Motor Kit - 120V 60Hz
  • Adam from BERKSHIRE, NY
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
door shelves were broken from use
simply replaced the pieces directly. It was very easy.
The different parts are easily deciphered and reassembled.
Parts Used:
6A- Door Shelf Retainer Bar End Cap - Left Side Refrigerator Door Shelf Retainer Bar - Cut to Fit Door Shelf Retainer Bar End Cap - Right Side Door Shelf Retainer Bar End Cap - Left Side
  • Murray from FORT MYERS, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The hole on the handle mounting block was too low
I had to loosen the screw holding the mounting block and increase the hole size to fit the screw on refrigerator
Parts Used:
Handle Mounting Block
  • Sadrudin from SAN DIEGO, CA
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    30 - 60 mins
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The Refrigerator was not cooling properly. At 40-45 degrees milk spoiled
My upper and bottom air diffuser was missing.
Purchased both air diffuser and placed it.
Parts Used:
Bottom Air Diffuser
  • Marcos from E STROUDSBURG, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Socket set
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator did not cycle
Installation was fairly straight forward. The major complaint is that the problem returned 2 weeks later. I don’t know if I care to re-invest in another switch.
Now what?
Parts Used:
Cold Control Thermostat
  • JACOB from YOUNGSTOWN, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Retaining bar was broke
Snap left and right end cap onto the retaining bar then snap onto the door
Parts Used:
5A - Door Shelf Retainer Bar End Cap - Right Side 6A- Door Shelf Retainer Bar End Cap - Left Side Refrigerator Door Shelf Retainer Bar - Cut to Fit
  • DOUGLAS from SEAGROVE, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator evaporator coil was icing up
The evaporator coil is behind the freezer. Remove the rack that makes the shelf and remove two 1/4” hex head screws I the back of the freezer to access the coil.
I used a hair dryer to melt the ice off the coil.
The thermostat clips on the refrigeration pipe to the coil. Remove the old thermostat and cut the wires at least a few inches from the thermostat. Clip the new thermostat on the pipe and strip about a 1/4” of the wire ends. The electrical connectors (provided with the new part) must be crimped to connect the wires.
Parts Used:
Defrost Thermostat
  • David from VENICE, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 25331432102