Ice Maker was leaking water and causing the ice to freeze into a block
First I removed the Ice bin, I then loosened the ice bin rail under the ice maker and removed the screw that attached the bottom of the ice maker to the side of the fridge. I unplugged the power to Ice Maker from the back of the fridge and unscreewed the two screws that secured the ice maker to the fridge. This allowed the Ice Maker to be removed from the fridge. To replace the new ice maker I simply repeated the steps in reverse.
Parts Used:
Replacement Ice Maker
  • Shelley from Katy, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
30 of 47 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer too warm; noticed sides of refrigertor were warm
I saw on a partselect web site that these symptoms could be caused by a failed condensor fan motor. After removing the cardboard panel in back of the refrigerator I noticed the fan was not running when the rfigerator was. The fan was held in place by three brackets. I unscrewed the screws holding the fan motor to the brackets and also unscrewed one of the brackets to make room to pull the motor out. I cut the wires close to the motor. I removed the fan blade and secured it to the new motor. I had to reroute the old wires in order to have enough slack to use wire nuts to attach them to the leads on the new motor. I then re-attached the motor to the two brackets remaining in place and then re-attacehed the third bracket I had removed to get the motor out.. The most difficult part was working in a very confined space.
Parts Used:
Condenser Fan Motor Kit
  • W from Nellysford, VA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
22 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The old motor wouldn't turn the fan.
After moving the refrigerator away from the wall I removed the cover on the lower back of the unit by removing the screws that held it in place. The condenser fan was not turning and there was heat build up in the area causing the refrigerator to not work properly creating elevated temperatures in both the freezer and regrigerator. Removal of three torx screws from the original motor was all it took to get the motor free. By turining it and working the fan blade around the mounting bracket I had the motor out in just a few minutes. Replacing the new motor was just as easy to reinstall. The fan was removed from the old motor and placed on the new for installation. The original motor was wired to accept a connector from the wiring harness of the refrigerator. I simply cut the connector off the wiring harness and stripped the insulation from the wires which easily allowed me to connet the wires of the motor and harness with two wire nuts. Three self tapping screws were used to hold the motor in place replacing the torx screws. Installed I plugged the unit in and immediately the fan started spinning as the unit came to life. Cleaned and replaced the cover over the back and slid back into its spot. Running as good as it did when it was new. Easy job to take care of.
Parts Used:
Condenser Fan Motor Kit
  • Bob from Hesston, KS
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Socket set, Wrench set
24 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Icemaker leaked water into ice bin causing a glob of ice
Philips head screwdriver and ten minutes was all it took! I removed the two screws that hold the icemaker assembly in place, then pulled it out a little and disconnected the electrical plug freeing the icemaker assembly. Then I snapped the external parts off my old icemaker assembly and snapped them on the new icemaker assembly. Installing the new icemaker assembly was just as fast and easy. I snapped the electrical plug into the new icemaker assembly, then screwed in the two screws. It was making ice shortly thereafter. Glob free ice! I'm glad I didn't call a repairman. I probably saved a hundred bucks. A ten year old could accomplish this simple and easy task. No wonder the Maytag repairman has time on his hands.
Parts Used:
Replacement Ice Maker
  • Kevin from Tyler, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
22 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Maker broke at the begining of summer !!!!!!
The new Ice Maker Assembly arived in less than 24 hours. I was amazed that it came so fast.

I had already removed the old ice maker in order to get the modle number.

I just took two parts off of the old ice maker and quickly snapped them into place on the new ice maker. Then attached it to the refrigerator in less than 10 minutes. With in a few hours I had ice again !!!!!

I would definatly use partselect.com again.
Parts Used:
Replacement Ice Maker
  • Darrell from Pepperell, MA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
20 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer would not keep food frozen
First you must unplug the refrigerator, then remove the top hinge and freezer door, then you must remove the middle hinge to remove the refrigerator door, after that there are 4 screws located in the refrigerator compartment that must be removed that are holding the plastic control knob trim in place. When you remove these screws and drop the trim piece you can unplug the wiring on it, to completly remove it, next right above the plastic trim previously removed there is a metal trim with 3 screws holding it in place they will be removed now. Now you need to remove all of the shelving in the freezer compartment these pieces will just snap out , at the lower left and right sides of the freezer compartment there are two plastic tips that are attached to the main plastic body of this compartment they will need to be snapped out from behind the metal body of the refrigerator this can be done with a flat head screwdriver. Now pull straight out on the plastic body and it should come out , this will expose an insulating cover over the freezer coil where the defrost heater is located,if this is covered with ice you will need a heat gun which is a overgrown hair dryer basically. To melt the ice you will have to remove a insulating cover that is located behind the previously removed front metal trim it will come out by gently snapping it out of place, use caution during this step so not to break the cover in half. This will expose the front of the freezer coil and you can now use the heat gun to melt the ice, keep a check on the drain pan beneath the refrigerator as it will have to be emptied depending on the amount of ice build up. As the ice melts it should release the top cover of the coil and this will lift out of place also again use caution when removing the cover. With the coil exposed melt the remaining ice, if you look in the coil you will see the defrost heater, if the glass tube on the heater is broken please use extreme caution so you will not get cut by it , now you can unplug each wire from each side of the heater you may need a pair of pliers for this. when the wires are unplugged you can now lift out the bad heater again use caution if the glass is broken. There is a gaurd over the heater that will have to be removed by sliding it off the end wires when you have this off, slide it over the wires on the new element, now gently install the new heater back in the coil reconnect the 2 end wires and make sure they are connected good. you can now assemble all of the covers and parts in the reverse order you removed them, when assenbly is complete plug the refrigerator back in and in about three hours or so you should here the fan and compressor stop and the unit should go into a defrost cycle during this you should here the water running to the drain pan as it melts.
Parts Used:
Defrost Heater
  • chuck from dudley, NC
  • Difficulty Level:
    Very Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Pliers, Screw drivers, Socket set
18 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice stripper broken on ice maker
I unplugged the fridge. Loosened the 2 top screws on the ice maker and removed the lower screw. I disconnected the wiring harness and removed the Ice maker. I removed the plastic timer cover in front. I then loosened the screws on the face of the ice maker and removed the broken ice stripper and replaced it with a new one. Re-tightened the screws on the face, installed the timer cover, plugged in the wiring harness, re-attached the ice maker. Plugged the fridge back in and walla, it was making ice in 30 minutes!
Parts Used:
Ice Stripper
  • Kenneth from New Braunfels, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
17 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice water valve leaking
Removed two screws holding valve, removed two 1/4" water lines. disconnected wire clip from old valve.
Installed new valve, connecting water and electrical with ease.
Absolutely Simple!
Parts Used:
Single Outlet Water Valve Kit
  • Byron from Steamboat Springs, CO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Pliers, Wrench (Adjustable)
13 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer was not staying cold enugh for ice maker to work. Discovered fan was not working to cool condensor. Fan motor would only run if manually turned.
Unplugged refrigerator. Removed lower back access panels and panel running up the back of refrigerator. Removed and disconnected old fan. Removed old fan motor from mounting bracket. Removed fan blade from old fan motor and placed on new fan motor. Connected new fan motor to power supply. Tested. Reinstalled.
Parts Used:
Condenser Fan Motor Kit
  • David from Cedarville, OH
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Screw drivers, Socket set
14 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Old Icemaker noisy and stopped making Ice
The old icemaker had a bad motor and would stall in the fill cycle causing my kitchen to flood on occasion.

The new one was so quiet, I thought it didn't work!

Anyway, one nutdriver and 5 minutes and I had the new one in there... It is so quiet, and I always have plenty of ice now!!!

Thanks!!!
Parts Used:
Replacement Ice Maker
  • Daniel from Rhinelander, WI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
18 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken cup water fill on ice maker
I called the local Amana repair man, wanted $150 for a new ice maker because they could not get the part I needed. Found Partsselect.com and the part cost $17 with shipping. They saved me over $100. The repair was very easy too, just removed a couple of screws.

Thanks,
Matt
Parts Used:
Water Fill Cup and Bearing
  • Matthew from Aurora, CO
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
13 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator Ice Maker stopped making ice.
(1) Removed the three screws which attached the ice maker to the freezing compartmnet wall in refrigerator; (2) Disconnected the power to the old ice maker; (3) Removed the old ice maker from the freezing compartment of the refrigerator; (4) Took the white front cover off of the old ice maker; (5) Disconnected the wiring harness from the old ice maker; (6) Removed the "ice making-stop arm" from the old ice maker; (7) Placed the items taken from old ice maker on to the new ice maker; (8) Reconnected the new ice maker to the power; (9) Placed the new ice maker in the proper position in freezing compartment of refrigerator and replaced the three screws. JOB DONE!
Parts Used:
Replacement Ice Maker
  • Harold from Oakton, VA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
18 of 34 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
condenser fan stopped working
1. Removed the cardboard cover.
2. Removed the terminal block and unplugged the old motor.
3. Removed three screws that held old motor to the bracket.
4. Removed the fan blade from the old motor.
5. Installed the fan blade (after cleaning) to the new motor.
6. Crimped on new wire terminals onto the leads on the new motor.
7. Installed the new motor using the fasteners provided.
8. Plugged the new motor wires onto the proper terminals in the terminal block.
9. remounted the terminal block.
10. reinstalled the cardboard cover.
Parts Used:
Condenser Fan Motor Kit
  • Steven from Brigham City, UT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Condenser fan motor seized
While investigating a water leak I discovered the condenser fan seized. I removed the fan to prevent a fire and ordered the part. The hardest part was identifying the correct fan. That took longer than the installation.
I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill.
Done
Total time of ice maker water leak repair and fan replacement about 1 hour.
Parts Used:
Condenser Fan Motor Kit
  • Benjamin from Daytona Beach, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers
9 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer Cooling Problems - would get too warm then too cold. Condenser fan would run sometime but not always
Unplug
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip holding the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels
Parts Used:
Condenser Fan Motor Kit
  • JAMES from Middleboro, MA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers, Socket set
10 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 21304-0A
16 - 30 of 460