light inside fridge was flickering and clicking
tested bulb good ,replaced door switch first(least expensive)then ordered light socket and circuitboard.If clicking sound is heard replace circuitboard first to save on return shipping because the switch and socket where ok
Parts Used:
Refrigerator Door Switch
  • bill from escondido, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
20 of 32 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
coupling on water line thru freezer door cut due to moving Refg and having to remove doors.
Snapped the large end of the coupling onto the main line coming from the water source and snapped the other end onto the small line leading to the ice maker. Quick and simple.
Parts Used:
Tube Connector - 1/4 Inch to 5/16 Inch
  • Martin from Rutherfordton, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
21 of 35 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Old Icemaker noisy and stopped making Ice
The old icemaker had a bad motor and would stall in the fill cycle causing my kitchen to flood on occasion.

The new one was so quiet, I thought it didn't work!

Anyway, one nutdriver and 5 minutes and I had the new one in there... It is so quiet, and I always have plenty of ice now!!!

Thanks!!!
Parts Used:
Replacement Ice Maker
  • Daniel from Rhinelander, WI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
18 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer was not staying cold enugh for ice maker to work. Discovered fan was not working to cool condensor. Fan motor would only run if manually turned.
Unplugged refrigerator. Removed lower back access panels and panel running up the back of refrigerator. Removed and disconnected old fan. Removed old fan motor from mounting bracket. Removed fan blade from old fan motor and placed on new fan motor. Connected new fan motor to power supply. Tested. Reinstalled.
Parts Used:
Condenser Fan Motor Kit
  • David from Cedarville, OH
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Screw drivers, Socket set
14 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice melting in freezer.
I first replaced the fan, because it wouldn't run, then replaced the defrost thermostat, because I didn't know how to test it, and the defrost control board, because it was all I thought was left. Turns out it was the defrost heater. The control board senses current flow through the heater and switches the fan off. With an open element the fan won't work. This can be tested with an Ohm meter. The thermostat will test open at room temperature, this is normal.
Parts Used:
Adaptive Defrost Control Board
  • Carl from Crossville, TN
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
14 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Icemaker quit working
The icemaker unit comes right off, only 3 screws hold it in place, so it was a breeze replacing it. I probably saved a couple hundred bucks by doing it myself, thanks to the great service at partselect.com.
Parts Used:
Replacement Ice Maker Ice Maker Wire Harness
  • Patrick from El Paso, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
13 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Waterflow to icemaker would not stop
Shut water off at source, disconnect electrical supply at wall, remove screws retaining cardboard dust cover, and remove cover. Removed water supply line to control valve, remove two screws retaining unit to frame of refrigerator, and gently pull out unit. Remove two water lines, making sure to note where each line was connected to unit. Remove two electrical connectors, making sure to note where each line was connected, remove old valve. Noting where mounting bracket is positioned, remove old mounting bracket from valve, and reinstall bracket on new valve the same way. Coat threads lightly on new valve with vaseline, reinstall valve in reverse order, making sure not to over-tighten water connections. Note, before installing dust cover, reconnect wall power, and turn on water and inspect for leaks, at connections. Tighten leaking connections very slightly until leak stops. Reinstall dust cover, and carefully return refrigerator to it's original location.
Parts Used:
Water Inlet Valve - 120V 60Hz
  • Don from Jacksonville, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers
12 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Lower RH door hinge was making a snapping noise because door closure cam screw backed out and damaged cam by egg-shaping hole.
Removed door. Removed old cam closure assembly. Noticed that there was almost nothing inside the door for screw to screw into(only styrofoam insulation), which is why original screw backed out. Bad design. Got longer screw at bigger diameter. Pushed high strength glue into hole, on screw threads, and underneath screw head. Assembled. Crossed fingers. About three weeks have passed and so far, so good.
Parts Used:
Door Closure Cam Kit
  • Keith from Glenview, IL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
11 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator Ice Maker stopped making ice.
(1) Removed the three screws which attached the ice maker to the freezing compartmnet wall in refrigerator; (2) Disconnected the power to the old ice maker; (3) Removed the old ice maker from the freezing compartment of the refrigerator; (4) Took the white front cover off of the old ice maker; (5) Disconnected the wiring harness from the old ice maker; (6) Removed the "ice making-stop arm" from the old ice maker; (7) Placed the items taken from old ice maker on to the new ice maker; (8) Reconnected the new ice maker to the power; (9) Placed the new ice maker in the proper position in freezing compartment of refrigerator and replaced the three screws. JOB DONE!
Parts Used:
Replacement Ice Maker
  • Harold from Oakton, VA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
18 of 34 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
fridge door would not close completely by itself
Removed the hinge cover, removed three hinge screws, removed door. Then I used a screwdriver to pry out the hinge bushings, pushed the new ones in and replaced the door. Both Maytag and Lowe's (who held the extended warranty) said that the door was not a repairable item and would have to replace the whole door. Since that would cost more than the value of the fridge, they voided the warranty and returned my cost. Too bad we didn't know about Part Select, we would have held their feet to the fire.
Parts Used:
Door Bushing - White
  • thomas from melbourne, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
10 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Condenser fan motor seized
While investigating a water leak I discovered the condenser fan seized. I removed the fan to prevent a fire and ordered the part. The hardest part was identifying the correct fan. That took longer than the installation.
I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill.
Done
Total time of ice maker water leak repair and fan replacement about 1 hour.
Parts Used:
Condenser Fan Motor Kit
  • Benjamin from Daytona Beach, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers
9 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
There was no light on in refrig area
Just replaced the switch, but unfortunately that was not the problem; nor was it the bulb....so I am back to square one.
But Parts Select is a great place to order from. Thank you.
Parts Used:
Refrigerator Door Switch
  • Lori from Chuluota, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
12 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
condenser fan stopped working
1. Removed the cardboard cover.
2. Removed the terminal block and unplugged the old motor.
3. Removed three screws that held old motor to the bracket.
4. Removed the fan blade from the old motor.
5. Installed the fan blade (after cleaning) to the new motor.
6. Crimped on new wire terminals onto the leads on the new motor.
7. Installed the new motor using the fasteners provided.
8. Plugged the new motor wires onto the proper terminals in the terminal block.
9. remounted the terminal block.
10. reinstalled the cardboard cover.
Parts Used:
Condenser Fan Motor Kit
  • Steven from Brigham City, UT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Defrost Cycle Was Not Function Properly
*
Parts Used:
Adaptive Defrost Control Board
  • Todd from Kemah, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
coils would not defrost
First ordered the defrost thermostat, did not fix, so next tried the defrost control board, and that did the trick. Easy except the clips holding the black box are very tight, a bit difficult to get the right angle and get the clips back on, but perserverance prevailed. Troubleshooting states could be one of 3 parts, we got lucky on the second.
Good Luck!
Parts Used:
Adaptive Defrost Control Board
  • Clifton from Evergreen, CO
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
9 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!