Fan was making noise, Freezer temperature was erratic
First, watched video on Part Select Website. Very good. Pulled Appliance out from wall, Pulled the power plug, and removed the back shield covering the working parts of the unit. Found the fan and it was almost the same setup as on the video except that I could not get to one of the screws holding the motor in place so had to remove the entire bracket with the fan. Not too hard. Cleaned away dust and gunk around the site and noticed that the fan pulled air through a tunnel-like condenser coil that was packed with gunky lint...this is what probably killed the motor. I cleaned out the tunnel with the bottle brushes and vacuum and installed the new motor / bracket assembly. Then replaced the shielding around the fan and the back cover .panel. This is important because these form the channel that guides air flow throughout the condenser coils. This particular refrigerator has a barrier underneath which guides air flow from the front left to the condenser, through the fan, over the evaporator drip pan and out the right front. I cleaned all the lint and gunk from this area as well. I also made an air filter (cut from a furnace filter) and wedged it in front of the air entry section. This should keep the condenser coil cleaner over time but you have to remember to change the filter once a year. Probably should clean the condenser coil every 5 years as well. This unit has been very reliable over 20 years and may well go for another 20. Good luck with your repair.
Parts Used:
Condenser Fan Motor Kit
  • Dik from Quincy, MA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Freezer and Refrigerator not cooling properly
Researched this problem on the web. Disassembled the main refrigeration unit (slide out freezer floor panel). The cooling coils were completely iced up. Thawed overnight. Tested the coil thermostat with a multimeter and discovered it worked. Note that the activation temp on this thermostat is 15 degrees Fahrenheit so the ice-water bath test on many web videos will NOT work. My test was in another refrigerator freezer compartment (everyone has two, right?). When the temperature went below 15 and stayed there for 15 minutes, the thermostat opened the circuit. Further investigation revealed that the defrost heater was burnt and shorted. Replaced the defrost heater only to discover that the defrost timer was also broken. After replacing the defrost timer and testing each component thoroughly, the refrigerator is back in service. Freezer maintains about 8 F and the main refrigerator stays at about 36. The unit cycles off properly and the defrost timer is correctly initiating a defrost cycle. Further, when the defrost heater is cycled on, the thermostat correctly shuts it off once the coils are defrosted. Watch the youtube videos. Find your parts and note their specifications so you can test them properly. And good luck.
Parts Used:
Defrost Heater
  • Edward from Sykesville, MD
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Screw drivers, Socket set, Wrench set
Was this instruction helpful to you?
Thank you for voting!
Condenser motor stopped working
Removed bad motor with socket set and pliers then removed the connectors from the old motor and soldered them on the new one. Then installed new motor. Works like new! Problem Solved! Easy fix!
Parts Used:
Condenser Fan Motor Kit
  • Chris from Greenville, OH
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers, Socket set
Was this instruction helpful to you?
Thank you for voting!
Condensor fan motor quit working
Pulled the fridge out, Took bottom panel off. Removed 3 screws holding motor. Unplugged connector, cut wires, attached old connector on new motor. put blade on new motor.installed in fridge, put cover back on.
Parts Used:
Condenser Fan Motor Kit
  • David from New Albany, IN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
condenser fan wore out
The kit I recieved was perfect. All parts fit and where a perfect match. I will give you an A+ in handling my order and shocked by speed of your delivery.
Parts Used:
Condenser Fan Motor Kit
  • Nancy from Gallatin, TN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Frig not cooling.
After plugging in the new relay to no avail. I replaced the thermostat. That fixed the problem.
Parts Used:
Capacitor
  • Adam from Randolph, ME
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
Was this instruction helpful to you?
Thank you for voting!
refridgerator was not cooling to the proper temps and finally would not cool at all
Pulled refridgerator forward away from the wall. Remove the cardboard back behind the appliance.I saw that the condenser fan motor was not working. Unplugged the appliance from the electrical outlet. Removed a 3 wire plug from the condenser fan motor. Remove 3 screws (with a nut driver) which held the condenser fan motor in place. Remove the condenser fan motor from the appliance. Looked up the part needed for repair using the appliance model number. Found which part was applicable for the appliance. Placed the order from Price Select on a Monday morning and recieved the part 2 days later on Wednesday via FedEx. The item shipped was a 2 wire condenser fan motor. Read the instructions that came with the part. Using wire cutters, cut the old 3 wire plug. The center wire is a green and yellow striped wire. Use the same colored wire that is also shipped in the box and has connectors on both ends. Cut one of the connectors off and use the wire strippers to remove plastic wire coating. Connect both ends from the appliance and the green and yellow wire that was shipped. Use a wire nut (also shipped in the box) to connect the wires. You will have 2 black wires left on the new condenser fan motor that need to be connected to the appliance. You should have an orange colored wire and another wire that is black with a white stripe. Connect one wire from the new fan motor to the orange wire and use a wire nut to attach both wires together. Use the other black wire from the new fan motor to the black/white striped wire from the appliance. Use the wire nut to attach both those wires. Place the new condenser fan motor back in the appliance using the screws that come with the motor. Attach the green and white wire with the connector on the end to one of the 3 screws that hold the motor in place and secure the screws. Use the electical tape to hold the wires all together and away from the fan motor. Plug the appliance into the outlet. You can see the condenser fan motor working properly. Note that when connecting the 2 black wires from the new condenser fan motor to the orange and the black/white wire from the appliance, for my appliance, it did not matter which wires were connected as the fan motor was a clockwise motor. Place the cardboard appliance backing, back on to the appliance and push the refridgerator back in place. Allow about 5-6 hours to get the freezer to between 0-5 degrees. The refidgerator should be between 34-38 degrees and will take a little longer to get to that projected temp.
Parts Used:
Condenser Fan Motor Kit
  • John from LAS CRUCES, NM
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Broken Ice Maker Motor From Plastic Ice Tray
Given that the augur motor had broken away from the ice tray, removal of the ice tray was simple. Simply remove one screw and slide the tray up and out. Removal of the motor was simple by squeezing the top and bottom of the wire harness plug located on the back of the freezer compartment wall, although it was by feel. The real problem came with trying to remove the augur from the motor shaft (it has a left hand tread) it is on tight and while trying to remove it – I stripped the threads on the motor shaft and couldn’t get the augur off. That’s when the cussing started. No easy fix for this so in addition to the ice tray, I had to order a new ice bucket auger drive motor kit (which included the augur for the end of the motor shaft). Once all the parts arrived, and I had the motor and solenoid assembled and mounted to the back of the tray, the hardest part was plugging the motor back into the plug on the back of the freezer wall- you’ll be doing this by feel (which is a poor design). One suggestion, take a picture of the wire connections between the motor and solenoid – just to be on the safe side – before taking it all apart.
Parts Used:
Ice Bucket Auger Drive Motor Kit
  • Jim from Washington, MI
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
Was this instruction helpful to you?
Thank you for voting!
Broken ice bin drive ring
Easy disassemble removing screws to separate front of ice bin.Be sure to note how metal rod is attached to rear of ice bin. Installed drive ring and reattached face (front) of ice bin in about 15 minutes.
Parts Used:
Ice Bin Drive Ring
  • James from Lincoln, NE
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
Was this instruction helpful to you?
Thank you for voting!
Fan motor worn out
My Son who is not an appliance repairman did it for me. He had some difficulty getting the nuts and bolts loose mainly. Sorry I'm not much help other than that! I would like to compliment you on your fast service, first time ordering from you and it was for an older model refrigerator that my repairman said he couldn't find. It's working fine now and I'm a satisfied customer!
Parts Used:
Condenser Fan Motor Kit
  • Myrna from Decatur, IL
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    1- 2 hours
Was this instruction helpful to you?
Thank you for voting!
condenser motor broke
opened box,read directions,took out bad motor,installed new one.PRESTO CHANGO way to go.
Parts Used:
Condenser Fan Motor Kit
  • patrick from livonia, MI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
wouldn't make ice, door seal was hot to touch, warm in fridge.
I folded in half twice! and took the back off the fridge(cardboard) and took one brace off and just took the screws off the fan from the other two braces. Turned the fan enough to get at the wires for the fan and cut them off an inch from the old fan, stripped the insulation and wire nutted them to new fan. Make sure they don't interfere with the new fan and put the new fan in place put the screws in and we're making ice and cold fridge again.
Parts Used:
Condenser Fan Motor Kit
  • Dale from Sterling, AK
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Socket set
Was this instruction helpful to you?
Thank you for voting!
intermittent loud whirring noise
Moved fridge out from wall, unplugged power cord. Laid on floor, removed 6 screws from cover. Removed one threaded bolt to allow assembly to slide out. Removed special nut, and took fan off. Removed 3 motor mounting bolts. Unscrewed 2 wire nuts, and untwisted wires. (option 1, no ground) Vacuumed entire area around motor. Used 3 bolts to mount motor to holder assembly, and special nut to install fan. Stripped wires back about 3/4 inch. Twisted two wires together CW, and installed new wire nuts. Slid motor assembly back into slot,(keep wires away from blades) and used one threaded bolt to secure assembly. Reinstalled cover plate with 6 screws. Plugged power cord in to test air flow (out through cover vents). Moved fridge back into place. The loud whirring noise did not stop for a day; then quiet!
Parts Used:
Condenser Fan Motor Kit
  • Honz from Tucson, AZ
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Socket set
Was this instruction helpful to you?
Thank you for voting!
Refrigerator was running very cold
Unscrewed the right control knob. Removed the left temperature control knob (there is no screw holding it), removed one screw to rear of small panel then pried open from the rear of the small panel, there are two plastic tabs in front of the small panel holding it in place. Unscrewed the failed control unit and replaced it with the new one. Replaced the small panel and screw then the left side control knob, making sure of the alignment in the "off" position as the knob has to be pressured into a clamp arrangement on the cold control thermostat. Re-screwed the right knob into place, as well.
Parts Used:
Cold Control Thermostat
  • Henry from Newland, NC
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Ice maker did not make ice
This review would not be helpful if limited to this part. So I will describe the whole repair. The ice maker was first receiving too much water. This resulted in huge cubes and water dripping out of the ice maker compartment. I tried reducing the amount of water using the valve to the supply line. But then the ice maker stopped making ice. I jumped to the conclusion that the solenoid water valve needed to be replaced. The new valve was easily replaced, but no water was delivered to the ice maker. I then went to the web site and saw that 87% of the time it was the ice maker itself that needed to be replaced. I ordered one and it arrived quickly. Installing it was easy although I might never had figured out how to remove the electrical supply line to the old unit if I hadn’t watched the video. After installation no water went to the ice maker tray.

I had read a review saying that the supply line had frozen where it went into the ice maker. To check out that possibility I removed the line from the solenoid valve and tried to blow air through it. No air would pass. So I removed the ice maker so I could get at the possible ice obstruction. I repeatedly inserted a knife honing steel which I heated and reheated in hot water. Finally I heard water dripping to the floor from the supply line which I had left detached from the solenoid valve. Then I hooked everything up and ice making proceeded nicely. If the solenoid valve ever needs replacing, I have a extra one.
Parts Used:
Double Outlet Water Valve Kit
  • Bruce from Kewadin, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Wrench (Adjustable)
Was this instruction helpful to you?
Thank you for voting!