Water / Ice dispenser would not stop flowing / running
3 of 3 people
found this instruction helpful.
-
Kevin from FOUNTAIN HLS, AZ
- A Bit Difficult
- 1- 2 hours
-
Screw drivers
Our 20+ year old Maytag refrigerator suddenly started dispensing water one day without anyone near the refrigerator. Thankfully, my wife was nearby; my son temporarily solved the problem by shutting off water to the house. The ice dispenser unit has a "Lock" switch which turns off power to the ice & water dispenser. With the switch in
... Read more
the "lock" position, we were able to continue using the refrigerator (and turn the water back on) until I was able to get a replacement part.
The biggest hurdle that I encountered was removing the trim; I spent perhaps an hour and a half trying to figure it out. In the end it turned out to be easy and would have been perhaps half an hour job total had I known the trick. So... to remove the trim on a Maytag RSW2400, you remove a single Phillips head screw on the bottom of the trim. The trim then slides to the left and can be removed.
The next mistake I made was removing the entire dispenser unit. Instead, if you look closely, there are screws which may be used to disassemble part of it, leaving the ice/water dispenser housing mounted to the refrigerator door. This provides access to the ice/water actuator switch. Perform this disassembly and access to the switch becomes obvious.
The switch is held in place with a single Phillips screw. Make sure that you've disconnected the power to the fridge well before this point because, AFAICT, 120VAC flows through this switch! The switch that I replaced didn't appear to be in bad shape and, once removed, the switch seemed to work correctly when I tested it with an ohmmeter. I replaced it anyway.
Reassembly was straightforward and easy. Better still, ice and water are now dispensed correctly again.
The biggest hurdle that I encountered was removing the trim; I spent perhaps an hour and a half trying to figure it out. In the end it turned out to be easy and would have been perhaps half an hour job total had I known the trick. So... to remove the trim on a Maytag RSW2400, you remove a single Phillips head screw on the bottom of the trim. The trim then slides to the left and can be removed.
The next mistake I made was removing the entire dispenser unit. Instead, if you look closely, there are screws which may be used to disassemble part of it, leaving the ice/water dispenser housing mounted to the refrigerator door. This provides access to the ice/water actuator switch. Perform this disassembly and access to the switch becomes obvious.
The switch is held in place with a single Phillips screw. Make sure that you've disconnected the power to the fridge well before this point because, AFAICT, 120VAC flows through this switch! The switch that I replaced didn't appear to be in bad shape and, once removed, the switch seemed to work correctly when I tested it with an ohmmeter. I replaced it anyway.
Reassembly was straightforward and easy. Better still, ice and water are now dispensed correctly again.
Read less
Was this helpful?
Thank you for voting!
Ice maker stopped making ice
3 of 3 people
found this instruction helpful.
-
Daniel from DAVISBURG, MI
- Really Easy
- Less than 15 mins
-
Nutdriver, Screw drivers
Remove 1 screw under ice maker. Gently pull downwards to unhook ice maker. Disconnected 4 pin wire connector. Remove and set aside the cover and wire loop you will need on new ice maker. Reverse the steps to install new maker. Once new ice maker is installed you will have to wait 2-4 hours for ice. There is a thermostat that will need to
... Read more
reach 10 degrees F to operate.
Read less
Was this helpful?
Thank you for voting!
Raplaced switch
5 of 9 people
found this instruction helpful.
-
Winston A from Brooklyn, NY
- Really Easy
- Less than 15 mins
-
Pliers
Repair went well,took about five to ten minutes to disconnect the power from the fridge removed the defective switch installed the new one ,reconnected the power,,,and Let there be light and there was light!
Was this helpful?
Thank you for voting!
Fill cup broke.
6 of 12 people
found this instruction helpful.
-
Aliki from Miami, FL
- Really Easy
- Less than 15 mins
Very easy to order from parts select. Took seconds to replace.
Was this helpful?
Thank you for voting!
Amana thermostat rusted
3 of 3 people
found this instruction helpful.
-
Lawrence from LAGRANGEVILLE, NY
- Really Easy
- 15 - 30 mins
-
Screw drivers
Add the new one it was slightly different than the original but it worked out perfect.
Other Parts Used:
Was this helpful?
Thank you for voting!
Refrig began to trip the GFI circuit in the garage. When plugged into a house interior circuit the lights and fan ran but no cooling in either the freezer or frig.
3 of 3 people
found this instruction helpful.
-
riley from CAVE CREEK, AZ
- Really Easy
- 15 - 30 mins
-
Pliers, Socket set
First of all I want to thank Michael from Carlisle,PA and this site for publishing Michael's info on the wiring specifics on the new 3 connector Start Relay ( WP2262185 ). The original relay only has 2 connectors The 2 orange wires which are combined to one female connector need to be clipped and separated each to its own connector. Ref
... Read more
er to Michael's blog as to which wire goes to which connector on the Start Relay. I replaced the Run Capacitor, Start Relay and Overload just to be safe. The Start Relay was the actual culprit.Thank you for an excellent website!
Read less
Was this helpful?
Thank you for voting!
lights wouldn't come on/work in refrigerator
4 of 6 people
found this instruction helpful.
-
Jane from Albuquerque, NM
- Easy
- 15 - 30 mins
-
Pliers, Screw drivers, Socket set
Referencing the info/schematics you have on your website, I unscrewed/unattached top-front panel (carefully), from behind the panel you have to detach the wires (2) from the switch, pushed "in" the switch to remove, put in new switch and attach wires to test BEFORE remounting panel. Tada!! Thank you PartSelect! You saved me at least $80..
... Read more
.would have been at least $100 to have a repair person come to the house!
Read less
Was this helpful?
Thank you for voting!
Ice maker stopped functioning
3 of 4 people
found this instruction helpful.
-
richard from colorado springs, CO
- A Bit Difficult
- 1- 2 hours
-
Nutdriver, Screw drivers, Socket set
Part received was what I needed. There was one issue--the 'feed' opening to receive water and direct it into the ice tray was a side feed and what I needed was a back feed. That means I had to do some exchanging of parts to make it work. That exercise took more time that the actual installation.
Was this helpful?
Thank you for voting!
The refrigerator stopped running
4 of 7 people
found this instruction helpful.
-
Barbara H. from South Hill, VA
- Easy
- 1- 2 hours
-
Screw drivers
I was told to order the run capacitor and the technician thought it would repair the refrigerator; but it did not. The appliance technician had to take the run capacitor off and install what he called a "hard start" and the refrigerator is operating right now.
Was this helpful?
Thank you for voting!
Divider front of fridge hot to touch Condenser fan not working
3 of 4 people
found this instruction helpful.
-
John from Holden, MA
- Easy
- 15 - 30 mins
-
Nutdriver, Pliers
removed back cover, removed fan motor and replaced with new one. connected new power wires. worked right away
Was this helpful?
Thank you for voting!
ice maker was over filling and causing water to flow into ice dispenser and freezing it al together
3 of 4 people
found this instruction helpful.
-
Michael from Moore, OK
- Easy
- 15 - 30 mins
-
Nutdriver
First turned off the water and unplugged the refrigerator and then removed the old ice maker by first removing the side cover plate and then next removed the ice level detector. Remove the screws that hold the ice maker in place and rotating it somewhat soas to gain access to the wires and then unplugged them. Next I had to modify the way
... Read more
the water comes into the new icemaker by adapting a CPVC street ell to fit into the hole on the side and then hook up the water supply. Installation is just the reverse of removal.
Read less
Was this helpful?
Thank you for voting!
Old Ice Maker failed
3 of 4 people
found this instruction helpful.
-
John from Gurnee, IL
- Really Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
I removed the old ice maker and during the short disassembly noticed a burned out connection to the heater element that allows the ice to be broken free of the tray and dumped into the bin. Part Select had a new unit to me next day! I had watched their short install video, and read some of the user comments, already. Re-installing the n
... Read more
ew unit was a snap, and just as the video had described except for the mount bracket. The only thing that concerned me was that the new unit did not immediately do anything. I began to investigate and found that the flexible water "chute" connection had ice in it! I unplugged the refer, unscrewed the water filter and drained it. I disconnected the water feed on the outside back of the unit as well to make sure water could flow easily to the ice maker port. I filled the water filter with boiling hot water and replaced it, I plugged in the refer, and reprogrammed the date and time. Several hours later I checked the ice maker and it was -- making ice!
Read less
Was this helpful?
Thank you for voting!
Water was leaking inside the refrigerator
3 of 4 people
found this instruction helpful.
-
Michael from Tampa, FL
- Really Easy
- 15 - 30 mins
-
Screw drivers, Wrench set
I got the part. The water connectors were different from the factory model. I thought to myself this will never work and it's going to leak everywhere. I push the water lines into the new water tank and not one leak!!! I now know why it was different, different is a lot better!! Thanks for the great Part, at the cheapest price.
Was this helpful?
Thank you for voting!
Refrigerator quit cooling and the freezer wasn't freezing anything
4 of 7 people
found this instruction helpful.
-
Tonya from Grand Prairie, TX
- Really Easy
- 15 - 30 mins
-
Socket set
Order the part from the Internet on Sunday, it mailed out on Monday and I received it on Tuesday. I unplugged the fan then undone 3 screws that held the fan bracket to the refrigerator pulled it out unscrewed 3 more nuts and replaced the fan on the bracket and I cut the old wire plug off the old fan and with 2 wire nuts put it on my new f
... Read more
an. Replaced the fan and bracket back on the refrigerator plugged it in and it works like a new refrigerator.
Read less
Was this helpful?
Thank you for voting!
changed the light bulb still would not work so I figured it was the switch sure enough.
3 of 4 people
found this instruction helpful.
-
anthony from HAVELOCK, NC
- Really Easy
- 15 - 30 mins
I took a chance and ordered a switch that is next to the top of the door. looked for how to remove it easily done in ten minutes works fine last long time.
Was this helpful?
Thank you for voting!