rReally Noisy Fan
  • Robert from Sierra Vista, AZ
  • Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
1. Unplug Refrigerator 2. Remove inside back freezer panel. (4 Screws) 3. Remove Duct Cover (3 Screws). 4. Cut electrical connections to fan. 5. Remove Old Fan motor (2 hex screws. 6. Install ground wire (was not one there previously). 7. Put slide-on electrical connectors on remaining 2 motor wires. (Were not any on original unit.) 8. R eplace Fan Motor (Don't forget the rubber vibration pads) 9. Reconnect electrical wires. 10. Press on plastic fan blade. 11. Plug in refrigerator to test install. It works. 12 Unplug refrigerator and replace ducting and back panel to freezer. Plug it back in. Voila, Quiet again.
Was this helpful?
Thank you for voting!
Noisy fan
  • Harry from Cincinnati, OH
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
Unplug the refrigerator. Remove the rear shelf supports by lifting them straight up. No tools required. Remove the screws holding the rear cover of the freezer. Use a nut driver to remove the 4 screws holding the fan housing. Unplug the wiring harness, then remove the fan and install the new one. Remount the housing, plug in the har ness replace the rear cover, install the shelf supports and plug in the refrigerator. It was 30 minutes start to finish, which includes the time to gather the tools, unload and reload the freezer, and putting the tolls away!
Was this helpful?
Thank you for voting!
not makinig ice due to lack of water flow to maker
  • David from Manlius, NY
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Pliers
Followedinstructions that came with kit. Kit parts were unnecessary as new valve fit in exactly as old one had been. Quick connect for flow out of valve to maker was a surprise as no threaded connection present and no nut necessary; simiply push the line into place. Reconnect water line, check for leaks and refasten back covering. Inst ructions with kit contained an incorrect drawing of connecting water outflowline; a one page addition verbally gave correct info, but detailed step by step instruction for this one connection was confusing. Otherwise, could not have been easier; surely a do-it-yourself project.
Was this helpful?
Thank you for voting!
Water Was Not Reaching The I Ce Maker
  • JOHN from TWINSBURG, OH
  • Easy
  • 15 - 30 mins
  • Pliers, Screw drivers, Wrench (Adjustable)
Disconnect ac power line, disconnect power line going to the water valve. Turn water off atthe cockvalve. Disconnect water line to valve. Disconnect plastic tubing going in the valve. If plastic is old you may have to replace it to keep from leaking at the quick connect coupling. Connect water line and plastic tubling to new valve, connect power clips to new valve. Plug in the refrigertor and turn on water at the cock valve and your good to go
Was this helpful?
Thank you for voting!
fan motor did not run all the time
  • Charles from Marion, IN
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Pliers, Screw drivers
unpluged refrigerator. removed panel in front of fan. Removed the fan motor. Installed the new fan kit. Replaced the panel in front of fan. Pluged the refrigerator back in. The refrigerator runs a 100 percent better
Was this helpful?
Thank you for voting!
Loud noise from freezer when running
  • Joseph from Cottsge Grove, WI
  • Easy
  • Less than 15 mins
  • Nutdriver, Pliers, Screw drivers
Pulled the electric plug! Removed the freezer shelf and the rear shelf supports by pulling straight up. Swung rear panel out of the way after taking out the two phillips head screws at the top. Removed the plastic deflector grill to which the motor is attached with a nut driver. Removed motor from grill and disconnected wire prongs (pul l off). Attach new motor. Only issue - the ground prong has been moved to the front of the motor so the wire just reaches and has to be gently bent back so the fan blade clears it. Reattach deflector grill. Push on fan blade, but not too far to hit wire. Reassemble the rest in reverse order.
Was this helpful?
Thank you for voting!
part not like old part
  • Lawrence from Pottstown, PA
  • Difficult
  • 30 - 60 mins
  • Screw drivers
The part could not be installed without home made angles which were attached to unit so that it would only protrude from back of refrigerator about 2" instead of 6".
Was this helpful?
Thank you for voting!
noisey circulating fan in the freezer
  • Lee from Arvada, CO
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
Emptied the freezer. Removed the back panel. (six screws)Removed the fan cover.(4 screws) Unplugged the power. Unplugged three wires from the motor. (hot-neutral-ground)Removed the fan. (2 screws) Installed the new fan and centered for clearance. Reversed the prior instructions.
Was this helpful?
Thank you for voting!
The fan in the freezer was squealing
  • Maxine from Henderson, NV
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
Took the old fan out and put the new fan in.
Was this helpful?
Thank you for voting!
New Part Was Different From Previous Part
  • Robert from Metuchen, NJ
  • A Bit Difficult
  • 1- 2 hours
  • Nutdriver, Screw drivers
First attempt was difficult. Part was different and instructions applied to previous part that did not have quick connect. Not clear where quick connect was to be used. Result no ice!second attempt used quick connect in reverse connections and now have plenty of ice. Combination of change in part appearence from previous one ,and diff erent from instructions included with new part, resulted in confusion in installation. In the long run, it worked out well.
Was this helpful?
Thank you for voting!
Evaporator fan motor stopped working
  • Kurt from Baltimore, MD
  • Difficult
  • 1- 2 hours
  • Nutdriver, Screw drivers, Wrench set
Remove back cover of freezer compartment; Remove old fan assembly, new fan terminals did not exactly match old one so I had to remove one of the terminals from old fan and attach it to new fan/ then install new assembly and repaced freezer cover
Was this helpful?
Thank you for voting!
Soleniod Valve Failed
  • BOB from LAKE HAVASU CITY, AZ
  • Difficult
  • More than 2 hours
  • Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
The refrig. Is about 30 years old. The new solenoid looked and mounted nothing like the original. I driled holes in the frig and attach the solenoid with sheet metel screws. There were not enough fittings and hoses so I bought a braded metal hose to attach the ro line and the valve inlet. I used the parts in the kit to attach the water feed line. To the ice maker I did not try to stuff all the hoses and lines back into the cramped cavity in the frig. W ell how does it look? The solenoid sticks out a little and there are a lot of hoses behind the frig. I do not spend much time behind the frig so who cares. The ice maker is making ice!