drum stopped turning on dryer
62 of 73 people found this instruction helpful.
  • Matthew from East Islip, NY
  • Easy
  • 30 - 60 mins
  • Screw drivers, Socket set
Great! Spent about $36.00 and I ended up with a overhauled dryer. I ended up cleaning the whole thing out, it's amazing how much stuff accummulates in the frame of a dryer, I also found about $2.00 in change. It's a good idea to clean out a dryer every few years and the broken belt forced me to do it.
But anyway the parts ca m very quick and had easy to follow directions.
I would reccomend part select. Matt
Was this helpful?
Thank you for voting!
door kept coming open dryer shuts off
95 of 176 people found this instruction helpful.
  • RONALD from SALMON, ID
  • Easy
  • Less than 15 mins
  • Pliers, Screw drivers
use screwdriver topry plastic out plyers to pull out metal latch put new parts in
Was this helpful?
Thank you for voting!
Replacing worn drum support rollers and shafts.
59 of 68 people found this instruction helpful.
  • Gary from Canton, CT
  • Easy
  • 15 - 30 mins
  • Nutdriver, Pliers, Screw drivers
Very easy once I figured out how to open it up to see what was the matter.
1 Remove power.
2 Open the lint filter cover and remove the 2 Phillip screws.
3 Pry the front of the top cover up to separate the cover from the plastic clips that secure to the top front panel.
4 Remove the 2 nut screws securing the top of the front panel to each side cover.
5 Pull front panel out slightly to detach wiring from the cover switch.
6 Pull front panel straight up and set aside.
7 Remove drum belt from tensioner and motor pulley under the drum.
8 Remove drum by pulling it toward the front between the 2 sides.
9 Locate the 2 support rollers and their mounting shafts. Change the shafts at this point if they are worn. (Mine were OK)
10 Remove the support bracket from the shaft if present.
11 Remove the plastic triangular retainer from the shaft and slide the old wheel off of the shaft.
12 Clean the shaft from any bearing debris.
13 Replace the rollers and retainers.
14 Insert drum through the front side panels making sure the seal on the rear of the drum is centered around the opening and not folded inside the opening.
15 Place the belt on the drum and thread the belt through the tensioner and around the motor pulley.
16 Position the front cover on the lower clips on each of the sides.
17 Re-attach the 2 wires for the cover switch.
18 Pull the drum up so the opening on the drum and front cover align.
19 Screw together the side panels to the front panel using the 2 hex headed screws.
20 Check for binds by rotating the drum several times by hand.
21 Press the front of the top panel down toward the front panel to engage the plastic clips attaching the top to the front. Watch for the lint filter housing alignment as you push the top panel down.
22 Replace the 2 screws to attach the lint filter to the top cover.
23 Plug in machine and test.

Good luck, It s not as bad as it sounds.
Was this helpful?
Thank you for voting!
The dryer would start to heat then the heat would stop
58 of 70 people found this instruction helpful.
  • Theodore from Riverside, CA
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver, Screw drivers, Wrench set
I changed out the cycling thermostat and the high limit thermostat. Mainly because that was what my research indicated was the problem. I then found some more information online that indicated the gas solenoid valves were bad. I ordered them from you and replaced them. The problem was fixed.

In order to replace the valves you need to remove the top panel. Two screws at the top of the front door assembly hold it on. Remove the screws, lift up on the front panel door assembly and move it to the side. The drum will rest in place. In the lower left corner, under the drum, you will see the solenoids. Two screws attach a plate that holds down the solenoids. Take the hold down plate off, disconnect the control wires attached to the solenoids and lift out the solenoid/control valves. To assemble everything, work backwards to the start. Good Luck
Was this helpful?
Thank you for voting!
dryer would get hot for a while, then quit heating
56 of 70 people found this instruction helpful.
  • Sharon from Houston, TX
  • Easy
  • 15 - 30 mins
  • Screw drivers
After reading about other people with this same problem I took a chance that this would be what was wrong with my dryer.I took off the front cover of the dryer by removing two screws. I located the faulty coils and simply plugged in the 2 new coils Tah-dah Probably coud have been done without even removing the front panel, but since it was off I vacuumed out the lint ( actually my husband did all of the above, but I tell a better tale than he does and I diagnosed the problem and ordered theparts)
Was this helpful?
Thank you for voting!
the dryer only blew cold air
48 of 52 people found this instruction helpful.
  • charles from waukesha, WI
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
actually i found your site before i even looked at the dryer,thats how i knew to check for the thermal fuse.
I ordered the part and it was on my door in 36
hours,pulled the two wires off the old fuse and installed the new,put the back cover on and it has been working ever since,thanks ( your in my bookmarks)
Was this helpful?
Thank you for voting!
Dryer motor would not turn on
51 of 69 people found this instruction helpful.
  • John from Bluffton, SC
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver, Pliers, Wrench set
After looking at the schematic to see what was in line with the motor, I found the fuse as the first item. I pulled the fuse out and used a multimeter to ohm out the fuse. Upon using the meter I found that the fuse was bad. I typed into Google my part number that was on the fuse and the PartSelect Website came up as one of the choices to pick from. When the part arrived approx. two days later I installed the fuse by first unplugging the dryer and then removing the bottom panel and removing the fuse from the exhaust by using a small 1/4 inch wrench and pulling out the old fuse. I installed the wires on the new fuse and re-installed and put the 1/4 inch screw back in. I started the dryer after plugging it back in and it worked like it should have. Thank you for the part and I have recommended your website to other people already.
Was this helpful?
Thank you for voting!
Gas Flame Would Drop Out
49 of 66 people found this instruction helpful.
  • FRED from BRIELLE, NJ
  • A Bit Difficult
  • 15 - 30 mins
  • Nutdriver, Screw drivers
First it was a process of alimination to find out why it was dropping out. After the problem was found it was just a matter of replacing the holding coil on the gas valve. Thank you fred kenney sr
Was this helpful?
Thank you for voting!
No power
45 of 55 people found this instruction helpful.
  • Nick from Brandon, FL
  • Easy
  • 1- 2 hours
  • Nutdriver
My 14 year old son did it as I supervised! Pulled the dryer out on a dolly, unpluged the dyer, removed 9 hex head screws to remove the back cover, removed and replaced the thermal fuse, located next to the exhust outlet, set the cover back on, moved the dryer back in with the dolly. I had the thermal fuse over nighted to me for a total price of $35, figured I saved at least $150 on a service call by Whirpool.
Was this helpful?
Thank you for voting!
Intermittent or no gas ignition, HSI ignightor working
43 of 50 people found this instruction helpful.
  • Steven from Sauk Village, IL
  • Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
Removed front of gas dryer and cleaned all lint out. Checked HSI, and cleaned flame sensor. Split (3 terminal) gas coil terminals were intermittent. Read about 700 ohms across outer two terminals, but center terminal to either outer terminal was open (Infiniti on meter) 2 terminal coil measured about 550 ohms. 3 terminal coil should read about 700 ohms across outer terminals, and about 1.5K ohms center to outer terminals. Unscrewed index cover plate and replaced coil, 2 terminal coil was okay. Reassembled and finished 12 loads of laundry no problems at all.
Was this helpful?
Thank you for voting!
Busted Belt & Pulley
43 of 51 people found this instruction helpful.
  • James from West Haven, CT
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
I bought a belt from a store in my area- What a mistake...I found this site and read all the stories on how easy it was and how PartSelect.com had the parts in stock and had easy instructions...I put the idler pulley in place, put the belt in place (all from instructions included) and put the dryer back together (which was easy). I actua lly did it alone. I would recommend this company to anyone in need of their parts and help!
Was this helpful?
Thank you for voting!
Dryer would not shut off on auto dry settings
42 of 50 people found this instruction helpful.
  • Wiliam from Belleville, MI
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
I removed the discharge duct from the back of the dryer. Then, I removed the screws on the back of the dryer and the back itself. This exposed the cycling thermostat. I removed the screw holding the thermostat. I took the wires off the defective thermostat and reinstalled them on the new thermostat. Then, I reassembled in reverse order.
Was this helpful?
Thank you for voting!
leaking from tub
41 of 49 people found this instruction helpful.
  • Debra from Milton - Freewater, OR
  • A Bit Difficult
  • More than 2 hours
  • Pliers, Screw drivers, Socket set
First I turned off the water and unplugged the washer from the outlet. I took the two screws off the console and turned it up to undo the clips that hold the cabinet to the back. I took out the 2 phillips screws at the top corners of the back. I was then able to pull cabinet off and not have to remove the console, but carefully slid it t o the side, as ther wires were still attached.
Pried off agitator cap & reached into agitator to pry out another cap to access 7/16 bolt. Checked over the agitator parts for wear (dogs) Took agitator, top outer (white) and inner (brown) tub rings off.
Sprayed lots of liqid wrench around spanner nut and drive block and gave it time to work. Used spanner tool to get spanner nut off. Hard work. Pounded and pounded and pounded and pounded with hammer. It gave a tiny bit. Then I got an idea: I pounded it back the other way, as you would to tighten. This helped. I then pounded back the other way and did this again. It worked amazingly well.
Got to drive block and it was rusted out along the bottom and also hard to get off. The diagram showed a "lock" (horseshoe shaped thing) on top of it, but mine was all in one piece but I couldn't tell that. I sprayed and pryed and pounded from the bottom and it split in half. It needed to be replaced anyway.
The inner tub was also hard to get out and I used some dish liquid. I pushed down, (using the rags here, the edges can cut you). I twisted, I pulled. I pushed, I pulled, I cussed, and begged. I then went to bed and then next day I pushed backwards and forwards and side to side & finally it came off. Then I undid the brackets on the bottom of the outer tub along the bottom and disconnected the clear hose in back. When loosening the black hose clamp in front to the pump, water started to come out of the hose so I grabbed a cool whip container to catch it. It smelled yucky. Once I had the outer tub off I put the new seal in, using some plumber's grease to help get ithe tub over the shaft..Then I hooked up the hoses & brackets on the bottom of the outer tub. I cleaned out the outer tub, as there was crud in the bottom. Then I poured about 5 gallons of water in it to see if the seal was set in right. Make sure the drain hose hasn't fallen out! (You can leave this water in the tub, you'll find out why) I cleaned up the rust on tube of the inner tub with steel wool and inspected everything else. Something didn't look quite right about the outer shaft that goes around the spin tube. It looked like something should go there. I discovered there SHOULD have been a seal there but one was never put in. So I put one in. I used a little grease to help put the new drive block on, and tightened the spanner nut with the spanner wrench. I put everything else back on EXCEPT for the cabinet-with the console attached. Ha Ha All the other directions I read wrote to take the console off first. If I had done that I wouldn't have been able to do the most important part of the job: testing the result. I finished filling the tub to the lowest water level to watch it go thru it's cycles and checked for leaks. If the console was "flopped over" the back how can you check? (I don't play with wiring)
I turned off the water & unplugged the washer and slid the cabinet on.. I tipped the console back to access the large gold squiggly brackets that hold the cabinet to the back and reattached them to the back, by removing them, hooking them onto the back, and snapping them into place. I double-DOUBLE checked to see if anything had come loose, then slid the console first on top of the back and put the two screws back in. The screws on my machine are not covered up by the end caps, but they are at a wierd angle, so I held the console up slighly and started the screws first. As they tightened down the console slid into the holes on the cabinet.
There is a small sppliance shop in my town & the guy loaned me the spanner wrench. It was very nice of him.I guess I will have to give his & his famil
Was this helpful?
Thank you for voting!
dryer makes a lot of noice, bad rolleres
37 of 40 people found this instruction helpful.
  • Jesus E from Palm Bay, FL
  • Easy
  • 15 - 30 mins
  • Nutdriver, Pliers
super fast shipping, got the part in two days, and had it done in 15-20 min, remove the front pannel, remove the belt and tenssioner,took the drum out , took the old rollers , lubed the shafts,replaced the old rollers with the new ones, intalled the drum back, the tenssioner and the new belt, reinstalled the front pannel, and done...easy and fast job, like new dryer, works nice...save some money...the new one will do the same..just dry the clothes.
Was this helpful?
Thank you for voting!
Gas burner would not ignite
37 of 42 people found this instruction helpful.
  • Jack from Conroe, TX
  • Really Easy
  • Less than 15 mins
  • Screw drivers, Wrench set
(I knew the gas coils were bad, since the gas ignitor would glow brightly as the burner attempted to ignite. So I knew everything except the gas valve was operating normally.)

Unplug the electrical cord to the dryer. Remove the front access panel. Remove the retainer clip for the gas coils (2 screws). Remove the coils and unpl ug the electrical connections. Connect the new coils to their respective electricl connections. Slide the nes coils back onto their respective posts on the gas valve. Replace the retainer clip, and 2 screws to hold it in place. (I then plugged the dryer back into the wall outlet to visually check the burner operation) Everything worked fine so I then replaced the front panel.
Was this helpful?